* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download xiao-ying-lu-southeast-university
Feature detection (nervous system) wikipedia , lookup
Selfish brain theory wikipedia , lookup
Biochemistry of Alzheimer's disease wikipedia , lookup
Brain–computer interface wikipedia , lookup
Neurophilosophy wikipedia , lookup
Convolutional neural network wikipedia , lookup
Brain Rules wikipedia , lookup
Neurolinguistics wikipedia , lookup
Neuroesthetics wikipedia , lookup
Donald O. Hebb wikipedia , lookup
Transcranial direct-current stimulation wikipedia , lookup
Artificial general intelligence wikipedia , lookup
Neuroinformatics wikipedia , lookup
Stimulus (physiology) wikipedia , lookup
Neural oscillation wikipedia , lookup
Artificial neural network wikipedia , lookup
Neuroplasticity wikipedia , lookup
History of neuroimaging wikipedia , lookup
Cognitive neuroscience wikipedia , lookup
Holonomic brain theory wikipedia , lookup
Functional magnetic resonance imaging wikipedia , lookup
Neuropsychology wikipedia , lookup
Molecular neuroscience wikipedia , lookup
Circumventricular organs wikipedia , lookup
Neuroeconomics wikipedia , lookup
Haemodynamic response wikipedia , lookup
Evoked potential wikipedia , lookup
Electrophysiology wikipedia , lookup
Neural correlates of consciousness wikipedia , lookup
Types of artificial neural networks wikipedia , lookup
Recurrent neural network wikipedia , lookup
Synaptic gating wikipedia , lookup
Clinical neurochemistry wikipedia , lookup
Optogenetics wikipedia , lookup
Single-unit recording wikipedia , lookup
Neuroanatomy wikipedia , lookup
Neurostimulation wikipedia , lookup
Development of the nervous system wikipedia , lookup
Nervous system network models wikipedia , lookup
Neural binding wikipedia , lookup
Channelrhodopsin wikipedia , lookup
Neural engineering wikipedia , lookup
Neuroprosthetics wikipedia , lookup
Neuropsychopharmacology wikipedia , lookup
Study of Micro-Electrode Array for Neural Populations Stimulating and Recording Xiaoying Lü1, Zhi-Gong Wang2 1State Key Lab of Bioelectronics 2Institute of RF- & OE-Ics Southeast University, 210096 Nanjing, China E-mail: [email protected] [email protected] 2014.7.8 Outline 1 Background and significances 2 Our researches 3 Summary 2 1. Backgound and significances Common geriatric diseases: The etiology unclear, Alzheimer’s disease (AD) no specific therapy. Parkinson’s disease Stroke Treat with drug Heart disease …… Brain research is full of challenge. It lays the foundation for: Explaining the brain mechanisms of human behavior; Understanding the information coding mechanism of neural circuits and neural network system; Clarifying the etiology and mechanism of neurological illnesses, exploring new method of treatment. 21 century is ‘the century of brain’: Related projects USA: BRAIN Initiative EU : The Human Brain Project (HBP) Japan: The age of brain science China: The cellular and molecular basis of brain function 3 Research of brain science Cellular and molecular levels Neural populations Whole brain level Biomics technologies (gene/protein expression, cell morphology, synaptic length, etc) Activity rule of the functional neural populations ? MRI (The changes of blood oxygen saturation and blood flow in brain) 4 Why MEA and neurochip? In order to understand the complex neural processing, high spatiotemporal resolution techniques to monitor the neuronal electrical activity are required. The development of MEA and neurochip provide powerful tools for investigating the electrical signal transmission and processing mechanism among neuron clusters in neural network, studying the function of the whole nervous system, thus overcome the “Great Gap” in brain research. With the invention of MEA in the early 1970s, related technologies have also been developed. MEA has been applied in : Neuroscience Drug screening Pharmacology, toxicology Etc. 5 Micro-Electrode Arrays (MEA) Micro electrodes are arranged on the glass surface in lattice formation Tissue, cell or slice can be put in the recording chamber of the MEA directly and tightly. Extracellular field potential signals from 60 sites can be recorded simultanously. The electrodes are used to record and stimulate. MEA is suitable for studying the electrophysiology and ion channel characteristics of neural network, brain slices and myocardial cells, heart slices. MEA plate Advantage: ★ Noninvasive ★ Record and stimulation ★ Long-term recordings ★ Study in space and time 6 MEA system diagram Advantages: ★ Real-time display ★ Multi channel recording ★ Sample selectivity ★ High resolution ★ High Throughput MEA system …… 7 1) Application of MEA for studying brain and heart slices Spontaneous electrical signal or induced signal can be detected from actue brain and heart slices placed on the MEA through MEA system. Then further research about neural system and autonomic nervous system could be carried out. Main research directions: Study of brain functions and dysfunction, cardiac diseases Study of neural signal transduction pathway 8 2) Application of MEA on pharmacology, toxicology and drug screening MEA is not only a special method to observe the activities of neural network, but also a drug screening method with the advantages of highthroughput, high sensitivity, stability and standardization. MEA can help us solve many problems in central nervous system drugs’ discovery, mainly including: (1) Screen and optimize of lead drugs (2) Verify action mechanism of drugs (3) Research neural properties of transgenic rodents (4) Verify safety/toxicity of compounds 9 2. Our researches 绑定线 焊盘 1) Development of MEA and neurochip PCB 信号探测放大/激励电路 信 号 探 测 放 大 、 激 励 电 路 3 1 1 神神神 22 信 号 探 测 放 大 、 激 励 电 路 信号探测放大、激励电路 硅片 引出线 2) Stimulation and detection of neural signal based on MEA 10 What is Neurochip? Neurochip technology is developed on base of MEA technology, it combines the neurons or brain tissue and FET technology to study the activity of neurons and advanced function, for example, learning and memory of brain. Advantages: Neurochip MEA • Overcome the interconnect limitations of commercial MEA, high-density sensor array could be realized. • Enable the integration of active circuits on one chip, such as recording amplifiers and stimulating buffer arrays, which can ensure signal integrity. 11 Design and Fabrication of a novel MEA and Neurochip using CMOS Technology: MEA in neurochip Channel Selecting Circuits Neural Signal Amplifier Neuron Body Size: 10~20mm Channel selecting circuits Signal Stimulating Circuit Neural Signal Amplifier and Stimulating Circuit Binding line Pad Channel selecting circuits Silicon Micro-photo of gold electrode outlet The Neurochip schematic diagram 12 The realization route 13 1) Development of MEA (1) PCB MEA design 50mm Working electrodes Layout of 60-sites MEA Final 60-sites MEA 60-sites MEA 100mm 30 2 MEA 14 (2) CMOS MEA Design Earth wire Pad Electrode Metal slot Earth wire Pad Electrode Throughhole Earth wire Connection line 22 MEA 4×4 MEA 14×14 MEA Improved 4×4 MEA 14×14 MEA 15 (3) Silicon-based MEA design 50mm Micro-photo of gold electrode Photographs of assembled 30 2 MEA and local closed view According to the size of silicon-based 302 MEA, the MEA is divided into two forms: culture chamber is directly adhered; or MEA is first bonded to the PCB board and then the culture chamber were adhered. 16 2) Development of neurochip The recording channels consisting of pre-amplifier, the stimulation channels and shift register circuits are designed. The results from on-chip test demonstrates that the recording and stimulation channels meets the performance need of monitoring the activities of neurons. The function of choosing different electrodes is performed by the shift registers and the conversion of the parallel data from recording channels to serial data is processed by the multiplex circuits. All aforementioned modules fulfill the design requirements. Furthermore, an integration of micro-electrodes array and microelectronic circuits are implemented. The measuring results shows that the integrated chip can record weak neural signals (µVs). 17 The neurochip integrated of MEA and multi-recording channels Technology: 0.5mm DPDM CMOS Size:5mm 5mm ① In red box: 64×64 MEA; ② In yellow box: 8-recording channels (4 channels each side); ③ In pink box: control circuits for choosing different electrodes from the MEA (8 pads on upside for row choosing and 8 pads on Die photo of the neurochip bottom for column choosing). 18 3) Stimulation and detection of neural signal based on MEA (1) The experimental environment and MEA system ① Million-level laboratory System accessories MEA2100 system Upright microscope, Data acquisition system MEA1060 system Inner room: Two detection systems Cell culture box Outer room: Upright microscope, data acquisition system Inner room: Biology experiment equipment 19 (2) The response signal recording of hippocampal neurons cultured on MEA under the electrical signal stimulating ① Culture of hippocampus on MEA Photos of cultured hippocampal neurons on the glass-based MEA after 14 days. Hippocampal neurons grew well on the MEA and formed network. 20 ② Single-channel electrical stimulation and multi-channel signal recording experiments of hippocampal neurons 4 Amplitude(?V) 1 x 10 0.5 0 -0.5 -1 0 5 10 15 20 25 Time(s) 2000 Amplitude(?V) Amplitude(?V) 2000 1000 0 -1000 -2000 0 1000 0 -1000 2 4 6 Time(ms) 8 10 -2000 0 2 4 6 Time(ms) The signal at stimulation of 55mV 8 10 The signal at stimulation of 55mV on the oscilloscope The hippocampus signal could not be recorded until the amplitude of stimulating signal reached 55mV. 21 ③Recording of hippocampal neurons cultured on MEA under electrical stimulation and different temperatures Excitation thresholds of hippocampal neurons under different temperatures mV 550 550 350 55 20 7 7 3 1 ∞ ºC 34 35 36 37 38 39 40 41 42 43 600 Threshold (mV) 500 400 300 200 100 0 33 34 35 36 37 38 39 40 41 42 43 Temperature (ºC) The signal at stimulation of 100mV and 34℃ Relationship between the excitation threshold and temperature As temperatures increases, the excitation threshold decreases quickly. Cell apoptosis occurs rapidly at 43ºC, with 36ºC and 38ºC being significant turning points. 22 ④Recording of hippocampal neurons cultured on MEA under electrical stimulation and influence of alcohol Excitation threshold of hippocampal neurons under different alcohol concentrations Alcohol concentration 0 10 20 30 40 50 60 70 80 90 100 110 Excitation threshold 55 130 160 185 195 200 220 290 420 550 900 1200 1400 Threshold(mV) 1200 1000 800 600 400 200 0 0 10 20 30 40 50 60 70 80 90 100 110 Concentration of alcohol (mmol/L) 37ºC, the signal at stimulation of 200mV and 50mM. 37ºC, relationship between the excitation threshold and alcohol concentration As alcohol concentration rises, the excitation threshold increases quickly. Cell apoptosis occurs rapidly at concentration of 110mM. 23 3. Summary The MEA which can record and stimulate, and a new neurochip design are implemented. Using the threshold of electrical signal to quantitative evaluate the influence of different stimulations on neural network are newly proposed. Electrical signals, temperature, alcohol and stimulating and signal recording experiments are performed. A series of useful results have been obtained for the quantitative evaluation of the electrophysiology activity of hippocampal neurons. Future work will study drug screening for Alzheimer’s disease and other age-related neurological diseases 24 Thank you very much for your attention ! Acknowledgement The National Natural Science Foundation of China (No. 61076118, 90707005); Special Foundation and Open Foundation of State Key Laboratory of Bioelectronics of Southeast University. 25