Download Retinal diseases

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Document related concepts

Subventricular zone wikipedia , lookup

Optogenetics wikipedia , lookup

Neural engineering wikipedia , lookup

Electrophysiology wikipedia , lookup

Cyborg wikipedia , lookup

Development of the nervous system wikipedia , lookup

Feature detection (nervous system) wikipedia , lookup

Single-unit recording wikipedia , lookup

Multielectrode array wikipedia , lookup

Channelrhodopsin wikipedia , lookup

Neurostimulation wikipedia , lookup

Neuroprosthetics wikipedia , lookup

Retinal implant wikipedia , lookup

Transcript
components needed for its operation. The
epiretinal systems requires the external camera,
which has to follow the movements of head or
eye, and the encoder unit, which will be tuned by
the patient. The operation of subretinal system
cannot be influenced from outside, once it is
implanted. This may be an advantage or a
disadvantage, depending on the quality of the
surgical operation. It is easier to integrate a
higher number of electrode sites onto the
subretinal device. Current designs will have a
number of 2000 electrode sites at a distance of
approximately 70 µm. In comparison, the current
epiretinal device is controlling only 24
microelectrodes. It is planned to increase twice
the number of electrode sites in future designs by
a factor of ten, yielding comparable electrode
numbers as the subretinal device. The technical
challenge is quite substantial in regard to heat
dissipation of electronic components and to
physically addressing the sites.
CONCLUSION
This research has shown how the
importance of the retinal implant, both epiretinal
and subretinal, is growing in the possible
applications to cure eye diseases.
However, it should be also pointed out
that the implemented systems are far from
nature’s sophistication. More than 100 million
photoreceptors receive the incoming light in
healthy eyes. About 1 million ganglion cells
produce signals that lead to the perception of
meaningful images. An approach with 20 or
2000 electrodes will always be crude.
Besides, even if the advances in genetic
and tissue engineering have the potential to
outperform a pure technical retina implant in the
far future, this project has proven that a retinal
implant is technically feasible today utilizing the
recent advances in MEMS technology.
REFERENCES
[1] Chow, A. Y. and Peachey, N. S. The
subretinal microphotodiode array retinal
prosthesis. Ophthalmic Res. 30[3], 195-198.
1998.
[2] Chow, A. Y. and Peachey, N. The
subretinal microphotodiode array retinal
prosthesis II. Ophthalmic Res. 31[3], 246. 1999.
[3] Clements, M., Vichienchom, K.,
Wentai, L., Hughes, C., McGucken, E.,
DeMarco, C., Mueller, J., Humayun, M., De
Juan, E., Weiland, J., and Greenberg, R. An
implantable power and data receiver and neurostimulus chip for a retinal prosthesis system. 1,
194-197. 1999. Proceedings of the 1999 IEEE
International Symposium on Circuits and
Systems VLSI (Cat. No.99CH36349).
[4] Eckmiller, R., Hunermann, R., and
Becker, M. Exploration of a dialog-based tunable
retina encoder for retina implants. 26-27, 10051011. 1999. 7th Annual Computational
Neuroscience Meeting (CNS 98).
[5] Kameda, S., Honda, A., and Yagi, T.
Real time image processing with an analog
vision chip system. Int. J. Neural Syst. 9[5], 423428. 1999.
[6] Kolnsberg, S., Kneip, T., Lu, X.,
Huppertz, J., Haushild, R., Schwarz, M.,
Hammershmidt, D., Hosticka, B. J., Ewe, L., and
Trieu, H. K. Microelectronic components for a
retina implant system. 218-221. 1999.
ESSCIRC'99. Proceedings of the 25th European
Solid-State Circuits Conference ESSCIRC'99.
[7] Meyer, J. U., Retina Implant – A
BioMEMS Challenge, vol. 1, Proceedings of the
11th International Conference on Solid-State
Sensors and Actuators, Munich, Germany, June
10 – 14, 2001.
[8] Nadig, M. N. Development of a
silicon retinal implant: cortical evoked potentials
following focal stimulation of the rabbit retina
with
light
and
electricity.
Clinical
Neurophysiology 110[9], 1545-1553. 1999.
[9] Sachs, H., Kobuch, K., Zrenner, E.,
and Gabel, V. P. Ab interno implantation of
subretinal microphotodiodes in rabbit and
micropig. Invest Ophthalmol. Vis.Sci. Vol 39[4],
S 903. 1998.
[10] Schubert, M. B., Hierzenberger, A.,
Baumung, V., Wanka, H. N., Nisch, W., Stelzle,
M., and Zrenner, E. Amorphous silicon
photodiodes
for
replacing
degenerated
photoreceptors in the human eye. 913-918. 1997.
Amorphous and Microcrystalline Silicon
Technology - 1997 Symposium
[11] Schubert, M. B., Stelzle, M., Graf,
M., Stert, A., Nisch, W., Graf, H. G., Hammerle,
H., Gabel, V. P., Hofflinger, B., and Zrenner, E.
Subretinal implants for the recovery of vision. 4,
376-381. IEEE SMC'99 Conference Proceedings.
1999 IEEE International Conference on Systems,
Man, and Cybernetics (Cat. No.99CH37028).
[12] Stieglitz, T., Beutel, H., Keller, R.,
and Meyer, J. U. Integrative design and hybrid
assembly of a flexible retina implant system. 1,
474. 1999. Proceedings of the First Joint
6