* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Components and Methods for Current Measurement
Electric power system wikipedia , lookup
Three-phase electric power wikipedia , lookup
Stepper motor wikipedia , lookup
Printed circuit board wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Electrical substation wikipedia , lookup
Electric machine wikipedia , lookup
Voltage optimisation wikipedia , lookup
Ground (electricity) wikipedia , lookup
Skin effect wikipedia , lookup
Transformer wikipedia , lookup
Power engineering wikipedia , lookup
Stray voltage wikipedia , lookup
Mercury-arc valve wikipedia , lookup
Mains electricity wikipedia , lookup
History of electric power transmission wikipedia , lookup
Transformer types wikipedia , lookup
Resonant inductive coupling wikipedia , lookup
Surface-mount technology wikipedia , lookup
Electrical ballast wikipedia , lookup
Magnetic core wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Galvanometer wikipedia , lookup
Surge protector wikipedia , lookup
Current source wikipedia , lookup
Thermal runaway wikipedia , lookup
Earthing system wikipedia , lookup
Buck converter wikipedia , lookup
Rectiverter wikipedia , lookup
Opto-isolator wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Network analysis (electrical circuits) wikipedia , lookup
designfeature Bryan Yarborough Applications Engineer, TT Electronics Components and Methods for Current Measurement C urrent sensing is used to perform two essential circuit functions. First, it is used to measure “how much” current is flowing in a circuit, which may be used to make decisions about turning off peripheral loads to conserve power or to return operation to normal limits. A second function is to determine when it is a “too much” or a fault condition. If current exceeds safe limits, a software or hardware interlock condition is met and provides a signal to turn off the application, perhaps a motor in a stalled condition or short circuit. It is essential to choose the appropriate technology with the necessary robustness to properly withstand the extreme conditions that can exist during a fault. A signal to indicate the “how much” condition and the “too much” condition is available in a variety of measurement methods: 1. Resistive (Direct) l RDCR 1:N a. Current Sense Resistors b. Inductor DC resistance RBurden I/N V= (I/N x RBurden) 2. Magnetic (Indirect) a. Current Transformer b. Rogowski Coil Ideal current transformer circuit c. Hall Effect Device Fig. 1. In the ideal current transformer ac current passes through the copper wind- 3. Transistor (Direct) a. RDS(ON) ings with very little resistive losses. b. Ratio-metric TTelec_F1 Each method has advantages for current measurement, but also comes with tradeoffs that can be critical to the end reliability of the application. They can also be classified into two main categories of measurement methods; direct or indirect. The direct method means that it is connected directly in the circuit being measured and that the measurement components are exposed to the line voltage, whereas the indirect method provides isolation that may be necessary for design safety. Current measurement components and methods must provide an accurate output signal as well as preventing damage to the associated printed circuit board. Current Sense Resistor Rogowski Coil Fig. 2. Rogowski coil is an air core design that has a lower inductance providing a faster response. The resistor is a direct method of current measurement that has the benefit of simplicity and linearity. The current sense resistor is placed in line with the current being measured and the resultant current flow causes a small amount of power to be converted into heat. This power conversion is what provides the voltage signal. Other than the favorable characteristics of simplicity and linearity, the current sense resistor is a cost-effective solution with stable Temperature Coefficient of Resistance (TCR) of < 100 ppm/°C or 0.01% /°C and does not suffer the potential of avalanche multiplication or thermal runaway. Additionally, the existence of low resistance (< 1 mΩ is available) metal alloy current sense products offer superior surge performance for reliable protection during short circuit and overcurrent events. TTelec_F2 28 Power Electronics Technology | January 2012 www.powerelectronics.com Drain l Gate VH = V VGS VDS VGS Hall effect principle, magnetic field present Fig. 3. Hall-Effect devices are capable of measuring large currents. TTelec_F3 Inductor DC resistance The DC resistance of an inductor can also be used to provide a resistive current measurement. This method is considered “lossless” because of the low resistance value of the copper, typically < 1 mΩ and because it is providing a secondary use of an existing component. In higher current applications; a 30 amp current would provide a 30 mV signal for a 1 mΩ resistance value. This method has two drawbacks; first copper has a high TCR (temperature coefficient of resistivity) of approximately 3900 ppm, which causes the resistance value to increase by 39% for a 100°C rise above room temperature. Because of this high TCR, the temperature must be monitored and compensated to provide an acceptable current measurement. The second drawback is the variance in the resistance of the copper due to dimensional changes that occur due to the conductor being wider or thinner from one lot to the next. Current Transformer A current transformer’s three key advantages are that it provides isolation from the line voltage, provides lossless current measurement, and the signal voltage can be large providing a measure of noise immunity. This indirect current measurement method requires a changing current, such as an AC, transient current, or switched DC; to provide a changing magnetic field that is magnetically coupled into the secondary windings (Fig. 1). The secondary measurement voltage can be scaled according to the turns ratio between the primary and secondary windings. This measurement method is considered “lossless” because the circuit current passes through the copper windings with very little resistive losses. However, a small amount of power is lost due to transformer losses from the burden resistor, core losses, and primary and secondary DC resistance. Rogowski Coil The Rogowski coil is similar to a current transformer in that Metal D N+ G N + + P VS SiO2 N+ S Source B Load ID ID Fig. 4. Power MOSFET’s on-resistance provides current sensing capability a voltage is induced into a secondary coil that is proportional to the current flow through an isolated conductor. The TTelec_F4 exception is that the Rogowski coil, (Fig. 2), is an air core design as opposed to the current transformer that relies upon a high permeability core, such as a laminated steel, to magnetically couple to a secondary winding. The air core design has a lower inductance providing a faster signal response and very linear signal voltage. Because of its design, it is often used as a temporary current measurement method on existing wiring such as a handheld meter. This could be considered a lower cost alternate to the current transformer. Hall Effect When a current carrying conductor is placed in a magnetic field, as shown in Fig. 3, a difference in potential occurs perpendicular to the magnetic field and the direction of current flow. This potential is proportional to the magnitude of the current flow. When there is no magnetic field and current flow exists, then there is no difference in potential. However, when a magnetic field and current flow exists the charges interact with the magnetic field, causing the current distribution to change, which creates the Hall voltage. The advantage of Hall effect devices is that they are capable of measuring large currents with low power dissipation. However, there are numerous drawbacks that can limit their VBAT Load Gate drive ISENSE R2 KELVIN/SOURCE R1 VSENSE RSENSE – + OUT VOUT Power ground Isf = senseFET current Fig. 5. SenseFET uses a small portion of its parallel MOSFET cells to sense current. TTelec_F5 www.powerelectronics.com January 2012 | Power Electronics Technology 29 currentmeasurement Fig. 6. (a) Shows a four-terminal resistor for current sense applications. (b) Shows two pad designs, (1) with isolated pad regions, and (2) with a plated through-hole. Pad Design 1 lel cells and connects to the common Gate and Drain, but separate Source. This creates a second isolated transistor; a “Sense” transistor. When the transistor is turned on, the current through the sense transistor will be a ratio comparable to the main current through the other cells. Depending on the transistor product, the accuracy tolerance range can vary from as low as 5% or as wide as 15% - 20%. This is not suitable for current control applications that typically require 1% measurement accuracy, but is intended for overcurrent and short circuit protection. Pad Design 2 Resistor technology benefits use, including non-linear temperature drift requiring compensation, limited bandwidth, low range current detection requiresTTelec_F6b.ai a large offset voltage that can lead to error, susceptibility to external magnetic fields, and high cost. Transistors Transistors are considered a “lossless” overcurrent detection method since they are standard control components to the circuit design and no further resistance or power dissipating devices are required to provide a control signal. Transistor datasheets provide the on-resistance for the drain-to-source, RDS(ON), with a typical resistance in the mΩ range for power MOSFETs (Fig. 4). This resistance comprises several components that begin with the leads connecting to the semiconductor die through the resistance that makes up the numerous channel characteristics. Based on this information, the current passing through the MOSFET can be determined by ILoad = VRDS(ON) / RDS(ON). Each constituent of the RDS(ON) contributes to measurement error that is due to minor variations in the resistances of the interface regions and TCR effects. The TCR effects can be partially compensated by measuring temperature and correcting the measured voltage with anticipated change in resistance due to temperature. Often times, the TCR for MOSFETs can be as large as 4000 ppm / °C, which is equivalent to a 40% change in resistance for 100°C rise. Generally, this method provides a signal with approximately 10% to 20% accuracy. Depending on the accuracy requirements, this may be an acceptable range for providing overcurrent protection. Ratio Metric Current Sense MOSFETs The MOSFET consists of thousands of parallel transistor cells that reduce the on-resistance. The current sensing MOSFET shown in Fig. 5 uses a small portion of the paral- 30 Power Electronics Technology | January 2012 Thin Film, are not typically used for current sense applications, but is included in this discussion to provide breadth to the topic. Generally these resistive products are for precision applications because of the resistive layer ranges from 0.000001 in. to 0.000004 in. thick. They are quite surge-tolerant in the appropriate application, but are not designed for the high currents typically associated with the applications mentioned here. (a) (b) OAR5 (2.94 Watts) Side View OAR5 (5.15 Watts) Side View OAR5 (5.15 Watts) Side View Fig. 7. Thermal images illustrating the isolation performance of the OAR and OARS product. TTelec_F7 www.powerelectronics.com Fig. 8. Differences in the thermal expansion coefficient between the metal materials of the current sense resistor and the circuit board materials dissipate forces on each part. TTelec_F8.ai Thick Film, is typically 0.0005 to 0.002 in. thick, which is nearly 100 times that of Thin Film. The increased thickness equates to a greater mass that is better able to carry the relatively high currents and dissipate the heat across the substrate, as well as better able to manage transients. Another advantage of the Thick Film products is the flexibility to request off standard resistance values because of the process efficiency of laser trimming. The tradeoff is that these products are not as capable of the very tight tolerances of Thin Film products. Foil, has a larger cross section still and is a uniform resistive alloy, which is different from the Thick Film technology that is resistive materials suspended in a glass matrix. By comparison the foils tend to withstand larger surge transients as compared to the previous versions. The principle advantage with this technology is the low range ohmic values with low TCRs. Bulk alloy, this resistor technology has the greatest surge tolerance because of its large current carrying mass. It is available in resistance values as low as 0.000 5 Ω with low TCR. This tends to be the best choice for high current power supplies or where fault conditions can result in extreme currents. These products do not have as wide of a resistance offering as the Thick Film products, because the resistor alloy has limited resistivities to reach high range values, as well as needing the mechanical strength to tolerate process handling. Product Specific Features High--current applications require the resistance value to be very low to minimize power losses and yet provide the necessary signal level to provide a voltage signal high enough to exceed noise levels. These low ohmic values often times need a four-terminal connection to reduce errors that may result due to the contact resistance that occurs when the part is mounted to the board. The CSL (Fig. 6a) offers four terminals by design, but other standard surface mount devices can benefit from a four-terminal pad design. These parts offer physically separated connection points for current and voltage, which reduces contact related measurement error. In the case of the CSL the current will flow through the inner pins and www.powerelectronics.com January 2012 | Power Electronics Technology 31 currentmeasurement voltage is sensed on the Measurement Method outer pins and is recommended for best accuracy with the Sense Resistor LRF3W to be configInductor DC resistance ured as a cross flow arrangement with curRDSon rent on opposing diaRatio Metric metrically corners (e.g., pin 2 to pin 3). Current Transformer The pad layout (Fig. 6b) creates separate Rogowski Coil regions for measuring Hall Effect signal voltage from the current carrying portion, which reduces error. Pad Design 1 illustrates one method that creates an isolated pad region within the pad layout, but this design may reduce the pad area below necessary limits to carry high currents through the copper trace. Pad Design 2 uses a plated through hole to connect under the pad and connects to an internal or outer trace for measurement; this maximizes the pad space to carry current to the resistor. The contact point places the signal line as close to the current channel as possible; minimizing measurement error. Accuracy Isolation EMI (Tamper Resistance) Robust Size Cost High No Low No High High Small Low Moderate High Small Low Low No Moderate Moderate Small Low Moderate No Moderate Moderate Small Moderate High Yes Moderate High Large Moderate High Yes Moderate High Large Moderate High Yes High Moderate Moderate High Resistive (Direct) Transistor (Direct) Magnetic (Indirect) formance. Observe the temperature of the solder joint with respect to the hot spot. These temperatures are based on reaching thermal equilibrium, however in the application these results may be extended to be considered as the thermal performance characteristics for an overcurrent protection condition. The FR4 will not exceed its temperature rating, though extreme circuit conditions exist. Solder Joint Stress The OARS product family’s elevated and curved construction permits the resistor Fig. 9. LRF3W from TT electronics uses side to flex, reducing the stress generated by differences in thermal expansion coeffiThermal Isolation terminations to achieve a 3W rating. cients between the heat producing metal The OARS (Open Air Resistor Surface and the dissipating circuit board material. Surface mount Mount) is a unique design that elevates the hot spot of components that are flat and parallel to the circuit board the resistive material well above the circuit board material. will apply shear forces to the solder joint that can lead to This places the hottest region of the part into the available failure or changes in performance. In high thermal cycling airstream, which dissipates the maximum amount of heat applications, the OARS has been preferred to other simienergy to the air instead of the PCB. lar all metal construction parts because of this flexibility This provides a two key advantages for thermal design, feature (Fig. 8). which affects the PCB material and the other neighboring power or semiconductor components. Typical FR4 PCB The LRF3W (Fig. 9) from TT electronics provides several material is only rated to 130°C; a power resistor that is design benefits derived from its 1225 aspect ratio with the traditionally against the board could cause damage to the termination along the long side of the component. The side material during power excursions or reduces the upper termination extends the power rating to 3 Watts, eliminates temperature performance limits of the circuit. An elevated the need to reduce the circuit traces as required by the tracurrent sense prevents damage to the circuit material and ditional 2512 footprint, and reduces solder joint stresses due permits the solder joint to run cooler. The second benefit to differences in the temperature coefficient of expansion by dissipating the heat to the air instead of the PCB is the between the ceramic and PCB material. The 1225 aspect improved performance of nearby heat-affected devices. reduces the distance between the center / hot spot region of These effects may include lifetime rating, power handling, the part and the thermally dissipative circuit board material. luminous output, accuracy, and reliability. This permits a high 3W rating and reduces the stresses on The thermal images shown in Fig. 7 help illustrate the the solder joint due to the differences in temperature coefficients of expansion between the ceramic substrate and the isolation performance of the OAR and OARS product. thermal mass of the board material. These tests were conducted on FR4 board material with no ambient airflow; airflow would improve system thermal per- 32 Power Electronics Technology | January 2012 www.powerelectronics.com