
Industrial Controls Monitoring and Control Devices 3UG4 / 3RR2 Monitoring Relays Gerätehandbuch
... documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems. ...
... documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems. ...
Objectives - e
... The 200-Hour Dislocated Workers’ Advanced Manufacturing/Integrated Systems Technology (AM/IST) curriculum is organized into three components: Electrical, Electronic and Mechanical. Each community college participating in the AM/IST grant received more curriculum than what is needed to complete the 2 ...
... The 200-Hour Dislocated Workers’ Advanced Manufacturing/Integrated Systems Technology (AM/IST) curriculum is organized into three components: Electrical, Electronic and Mechanical. Each community college participating in the AM/IST grant received more curriculum than what is needed to complete the 2 ...
Instruction manual 850 Feeder Protection System
... © 2013 GE Multilin Incorporated. All rights reserved. GE Multilin 850 Feeder Protection System instruction manual for revision 1.1x. 850 Feeder Protection System, EnerVista, EnerVista Launchpad, and EnerVista 8 Series Setup are registered trademarks of GE Multilin Inc. The contents of this manual a ...
... © 2013 GE Multilin Incorporated. All rights reserved. GE Multilin 850 Feeder Protection System instruction manual for revision 1.1x. 850 Feeder Protection System, EnerVista, EnerVista Launchpad, and EnerVista 8 Series Setup are registered trademarks of GE Multilin Inc. The contents of this manual a ...
Harmonic management of transmission and distribution systems
... computer power supplies and battery chargers[10-12]. For example, standard industrial variable speed drives use the dc or induction motor with thyristor or rectifier respectively. The converters which produce a high frequency supply will b e c o m e more c o m m o n to be used for lighting systems d ...
... computer power supplies and battery chargers[10-12]. For example, standard industrial variable speed drives use the dc or induction motor with thyristor or rectifier respectively. The converters which produce a high frequency supply will b e c o m e more c o m m o n to be used for lighting systems d ...
Vinculum-II PWM Example
... Clearance No.: FTDI# 146 The following describes what happens in modes 1 and 2. In mode 1, DIR is driven high and BRAKE is driven low. PWM is driven by VNC2. With a VNC2 PWM signal modulated at 50% duty cycle, the motor will spin forward at normal speed. As the duty cycle is reduced, the motor will ...
... Clearance No.: FTDI# 146 The following describes what happens in modes 1 and 2. In mode 1, DIR is driven high and BRAKE is driven low. PWM is driven by VNC2. With a VNC2 PWM signal modulated at 50% duty cycle, the motor will spin forward at normal speed. As the duty cycle is reduced, the motor will ...
gate circuit
... 3. to study how to express the required mathematical model 4. To determine the turning-off time, and how could be affected 5. Describing some examples ...
... 3. to study how to express the required mathematical model 4. To determine the turning-off time, and how could be affected 5. Describing some examples ...
Applications for SIPROTEC Protection Relays
... This should be taken into account in the choice of circuit-breakers. The system configuration and the specific requirements regarding switching time must therefore be analyzed before choosing the suitable rapid switchover. The following typical applications are particularly ...
... This should be taken into account in the choice of circuit-breakers. The system configuration and the specific requirements regarding switching time must therefore be analyzed before choosing the suitable rapid switchover. The following typical applications are particularly ...
The Art and Science of Protective relaying
... operation, 101 see also Line protection with pilot relays Pilot relaying, circulating current, 92, 94 general, 86 line protection, 373, 374 opposed voltage, 92, 95 pilot-wire protection, 98 pilotwire requirements, 97 pilot-wire supervision, 97 remote tripping, 97 see also Line protection with pilot ...
... operation, 101 see also Line protection with pilot relays Pilot relaying, circulating current, 92, 94 general, 86 line protection, 373, 374 opposed voltage, 92, 95 pilot-wire protection, 98 pilotwire requirements, 97 pilot-wire supervision, 97 remote tripping, 97 see also Line protection with pilot ...
Table of contents: 1. Introduction 2. General requirements 2.1
... Electric cables - Calculation of the current rating - Current rating equations (100% load factor) and calculation of losses - General Electrical installations of buildings Basic and safety principles for man-machine interface, marking and identification Identification of conductors by colours or num ...
... Electric cables - Calculation of the current rating - Current rating equations (100% load factor) and calculation of losses - General Electrical installations of buildings Basic and safety principles for man-machine interface, marking and identification Identification of conductors by colours or num ...
Transformer Modelling Guide
... Version: Revision 2 The intent of this document is to provide a general guide for the purpose of assisting AESO and other authorized parties with modelling of transformers in the electrical network of Alberta. All authorized parties may use this guide only for the purpose for which it is intended an ...
... Version: Revision 2 The intent of this document is to provide a general guide for the purpose of assisting AESO and other authorized parties with modelling of transformers in the electrical network of Alberta. All authorized parties may use this guide only for the purpose for which it is intended an ...
frick® quantum™ lx compressor control panel
... TYPICAL SYSTEM CONFIGURATION............................................................................................................4 QUANTUM™ LX CONTROL PANEL...................................................................................................................4 ...
... TYPICAL SYSTEM CONFIGURATION............................................................................................................4 QUANTUM™ LX CONTROL PANEL...................................................................................................................4 ...
operation frick® quantum™ hd compressor control
... Some screens are for informational purposes only, and cannot be modified. These screens typically show analog values such as temperature and humidity, which are strictly functions of an associated sensor, and as such, cannot be modified. Other screens show setpoint values which can be changed, in or ...
... Some screens are for informational purposes only, and cannot be modified. These screens typically show analog values such as temperature and humidity, which are strictly functions of an associated sensor, and as such, cannot be modified. Other screens show setpoint values which can be changed, in or ...
615 series ANSI Technical Manual
... persons responsible for applying the equipment addressed in this manual must satisfy themselves that each intended application is suitable and acceptable, including that any applicable safety or other operational requirements are complied with. In particular, any risks in applications where a system ...
... persons responsible for applying the equipment addressed in this manual must satisfy themselves that each intended application is suitable and acceptable, including that any applicable safety or other operational requirements are complied with. In particular, any risks in applications where a system ...
Thyristor Device Data - rsp
... purpose, nor does SCILLC assume any liability arising out of the application or use of any product or circuit, and specifically disclaims any and all liability, including without limitation special, consequential or incidental damages. “Typical” parameters which may be provided in SCILLC data sheets ...
... purpose, nor does SCILLC assume any liability arising out of the application or use of any product or circuit, and specifically disclaims any and all liability, including without limitation special, consequential or incidental damages. “Typical” parameters which may be provided in SCILLC data sheets ...
Servo - Servos
... sending the servo a coded signal. As long as the coded signal exists on the input line, the servo will maintain the angular position of the shaft. As the coded signal changes, the angular position of the shaft changes. In practice, servos are used in radio controlled airplanes to position control su ...
... sending the servo a coded signal. As long as the coded signal exists on the input line, the servo will maintain the angular position of the shaft. As the coded signal changes, the angular position of the shaft changes. In practice, servos are used in radio controlled airplanes to position control su ...
0.9 Mb PDF - David Kleinfeld
... This must intercept IDS = IDSS in the active region. Here, we slide along the (flat) line of ID = IDSS so long as VDS > - VGS(off). To find the maximum load resistance that keeps us in the active zone, we first rewrite the load line as an expression for VDS, i.e., VDS = VDD - IDSS RLoad Noting that ...
... This must intercept IDS = IDSS in the active region. Here, we slide along the (flat) line of ID = IDSS so long as VDS > - VGS(off). To find the maximum load resistance that keeps us in the active zone, we first rewrite the load line as an expression for VDS, i.e., VDS = VDD - IDSS RLoad Noting that ...
Design of high frequency circuits for a gigabit per second data
... I'd like to acknowledge the support of my co-major professors, Dr. Bill Black of Xilinx, Inc, and Dr. Robert J. Weber for all of their support and encouragement throughout my research under their guidance. Without them, this research project would be impossible to achieve. I'd like to thank Dr. Marw ...
... I'd like to acknowledge the support of my co-major professors, Dr. Bill Black of Xilinx, Inc, and Dr. Robert J. Weber for all of their support and encouragement throughout my research under their guidance. Without them, this research project would be impossible to achieve. I'd like to thank Dr. Marw ...
HVAC Specification for Variable Speed Drives (VSDs) Project Name
... This document details the feature and specification requirements for VSDs (variable speed Drives) to be used in the above mentioned project. VSD’s are designed for use with AC induction motors rated for variable speed control. Submission of suitable VSD candidates will be based on this document. Any ...
... This document details the feature and specification requirements for VSDs (variable speed Drives) to be used in the above mentioned project. VSD’s are designed for use with AC induction motors rated for variable speed control. Submission of suitable VSD candidates will be based on this document. Any ...
Stepper motor

A stepper motor or step motor or stepping motor is a brushless DC electric motor that divides a full rotation into a number of equal steps. The motor's position can then be commanded to move and hold at one of these steps without any feedback sensor (an open-loop controller), as long as the motor is carefully sized to the application in respect to torque and speed.Switched reluctance motors are very large stepping motors with a reduced pole count, and generally are closed-loop commutated.