* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Options - MTE - Meter Test Equipment
Survey
Document related concepts
Variable-frequency drive wikipedia , lookup
History of electric power transmission wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Power MOSFET wikipedia , lookup
Surge protector wikipedia , lookup
Electromagnetic compatibility wikipedia , lookup
Buck converter wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Three-phase electric power wikipedia , lookup
Current source wikipedia , lookup
Power electronics wikipedia , lookup
Stray voltage wikipedia , lookup
Voltage optimisation wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Opto-isolator wikipedia , lookup
Portable appliance testing wikipedia , lookup
Transcript
MTE´s Portable Product Portfolio Page 1 March April 2011 2012 MTE Portables Page 2 March 2012 K 2006 3-phase Comparator 30 V … 500 V 1 mA … 160 A Accuracy 0.01% 15 Hz - 70 Hz Measurements of: voltage, current, active, reactive and apparent power, energy, frequency, power factor, error measurement and harmonic analysis DC reference voltage input Options: CAMCAL® Software CALSOFT Software Page 3 March 2012 PRS 400.3 3-phase portable Reference Standard 0 V … 520 V (phase-neutral) 1 mA … 120 A direct connections Clamp-on CTs: 100A 1.000A FLEX 3000 up to 3.000A / Hot sticks for measurement on high voltage potential Vector diagram, harmonics spectrum, wave form and rotary field display Burden measurement and ratio tests of CT’s and PT’s Transducer test Accuracy 0.02 % Page 4 March 2012 CALPORT 300 3-phase Meter and Instrument Transformer Test System 40 mV … 480 V 1 mA … 120 A Accuracy 0.05 % 6 current inputs parallel for primary / secondary current measurement Measurements of all electrical parameters (incl. vector diagram) CT / PT testing (burden, ratio) Options: CALSOFT Software Clamp-on CTs for 100A 1000A FLEX 3000 up to 3000A LiteWire Sensors up to 2000 A and 40 kV Page 5 March 2012 PWS 3.3 3-phase Portable Working Standard and PQ Analyzer Working Standard Functions 20 mV … 600 V (phase-neutral) 1 mA … 12 A direct connection Measurements of all electrical parameters (incl. vector diagram) CT / PT testing (burden, ratio) Accuracy 0.1 %, 0.05 % PQ Analysis Functions Harmonics Interharmonics Signal voltages Dips Swells Interruptions Voltage unbalance Options: Clamp-on CTs for 100A 1000A FLEX 3000 up to 3000A LiteWire Sensors up to 2000 A and 40 kV Page 6 March 2012 PWS 2.3 PLUS 3-phase Working Standard 20 mV … 300 V (phase-neutral) 1 mA … 12 A direct connection 10 mA … 100 A via clamp-on CTs Measurements of all electrical parameters (incl. vector diagram) CT / PT testing (burden, ratio) Accuracy 0.1 %, 0.2 % Options: CALSOFT I Software Clamp-on CTs for 1000A FLEX 3000 up to 3000A LiteWire Sensors up to 2000 A and 40 kV Page 7 March 2012 CheckMeter 2.3 3-phase Working Standard 10 V … 300 V Auxiliary supply from the auxiliary supply or the measuring circuit 10 mA ... 100 A via clamp-on CTs Measurements of: voltage, current, active, reactive and apparent power, energy, frequency, power factor, error measurement, vector diagram Accuracy 0.2 % Options: CALSOFT I Software Clamp-on CTs up to 120 A (Measuring range 100 mA … 120 A, Cable : max 52 mm) Page 8 March 2012 CheckMeter 2.1 3-phase Working Standard 10 V ... 300 V Auxiliary supply from the auxiliary supply or the measuring circuit 10 mA ... 100 A via clamp-on CT Measurements of: voltage, current, active, reactive and apparent power, energy, frequency, power factor, error measurement Accuracy 0.2 % Options: CALSOFT I Software Clamp-on CTs up to 120 A (Measuring range 100 mA …120 A, Cable : max 52 mm) Page 9 March 2012 MTE Portables Page 10 March 2012 PPS 400.3-12 A 3-phase portable Voltage and Current Source 0 V ... 300 V / 50 VA / Phase 1 mA ... 12 A / 30 VA / Phase Phase shifter -180° ... 0 ... +180° 45 ... 400 Hz Stability 0.005 %/h ( = 150 s) Generation of harmonics up to 31st Ripple control signals Options: CALSOFT II CAMCAL for Windows Page 11 March 2012 PPS 400.3-120 A 3-phase portable Voltage and Current Source 0 V ... 300 V / 50 VA / Phase 1 mA ... 120 A / 80 VA / Phase Phase shifter -180° ... 0 ... +180° 45 ... 400 Hz Stability 0.005 %/h ( = 150 s) Generation of harmonics up to 31st Ripple control signals Options: CALSOFT II CAMCAL for Windows Page 12 March 2012 PPS 3.3 C 3-phase portable Voltage and Current Source 0 V ... 480 V / 30 VA / Phase 1 mA ... 120 A / 60 VA / Phase Phase shifter -180° ... 0 ... +180° 45 ... 400 Hz Stability 0.03 %/h ( = 150 s) Generation of harmonics up to 31st Ripple control signals Options: CALSOFT II CAMCAL for Windows Page 13 March 2012 CheckSource 2.3 3-phase electronic Current Source 1 mA ... 6 A / 8 VA / Phase Phase shifter -180° ... +180° Stability better than 0.03 % (30 min) 0.1 % (1 h) Single phase supply 50 VA (typical) 65 VA (maximum) Options: CALSOFT Software Page 14 March 2012 MTE Portables Page 15 March 2012 PTS 400.3 3-phase portable Test system with Voltage and Current Source Voltage source 0 ... 300 V Current source 1 mA ... 12 A / 120 A Reference standard accuracy class 0.02 % Measurement of all electrical values Vector diagram, harmonic test, Data storage, Ratio test, Burden test Automatic test runs without external PC Options: High current cables up to 120 A Several Clamp-on CT´s CALSOFT II Software CAMCAL for Windows Page 16 March 2012 PTS 3.3 C 3-phase portable Test system with Voltage and Current Source Voltage source 30 ... 480 V Current source 1 mA ... 120 A Integrated working standard accuracy class 0.05 % Measurement of all electrical values Vector diagram, Harmonic test, Data storage, Burden test Automatic test runs without external PC Options: High current cables up to 120 A Clamp-on CT´s 10 mA ... 100 A CALSOFT II Software Page 17 March 2012 Checksystem 2.1 S 1-phase portable Test system with Current Source Measurement range 10 mV ... 480 V Current source 1 mA ... 120 A Integrated working standard accuracy class 0.05 % Measurement of all electrical values Vector diagram, Harmonic test, Data storage Automatic test runs without external PC Options: Clamp-on CT 10 mA ... 100 A CALSOFT Software Page 18 March 2012 PTS 3.1 C 1-phase portable Test system with Voltage and Current Source Voltage source 30 ... 480 V Current source 1 mA ... 120 A Integrated working standard accuracy class 0.1 % Measurement of all electrical values Vector diagram, Harmonic test, Data storage, Burden test Automatic test runs without external PC Options: High current cables up to 120 A Clamp-on CT 10 mA ... 100 A CALSOFT II Software Page 19 March 2012 PTS 2.3 C 3-phase portable Test system with Current Source Measurement range 20 mV ... 500 V Current source 1 mA ... 120 A Integrated working standard accuracy class 0.1 % Measurement of all electrical values Vector diagram, Harmonic test, Data storage, Burden test, C.T. ratio test Automatic test runs without external PC Options: Clamp-on CTs for 100A 1000A FLEX 3000 up to 3000A CALSOFT II Software Page 20 March 2012 Checksystem 2.3 3-phase portable Test system with Current Source Measurement range 10 mV ... 300 V Current source 1 mA ... 16 A Integrated working standard accuracy class 0.2 % Measurement of all electrical values Vector diagram, Harmonic test, Data storage Automatic test runs without external PC Options: Clamp-on CTs 10 mA ... 100 A CALSOFT Software Page 21 March 2012 Checksystem 2.1 1-phase portable Test system with Current Source Measurement range 10 mV ... 300 V Current source 1 mA ... 120 A Integrated working standard accuracy class 0.2 % Measurement of all electrical values Vector diagram, Harmonic test, Data storage Automatic test runs without external PC Options: Clamp-on CT 10 mA ... 100 A CALSOFT Software Page 22 March 2012 CALSOFT Software tool to portable devices Automatic single position measurement Easy to understand presentation of all stored measured values Vector diagram Presentation of measured values Presentation of harmonics Print and data export functions Works together with following portables: K2006 PRS 400.3 / CALPORT 300 / PWS 3.3 PWS 2.3 PLUS / CheckMeter 2.x PTS 400.3 / PTS 3.3 C / PTS 3.1 C PTS 2.3 C / CheckSystem 2.x PPS 400.3 / PPS 3.3 C / CheckSource 2.3 Page 23 March 2012