* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download 2330 Level 2 Electrotechnical Technology
Mechanical-electrical analogies wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Telecommunications engineering wikipedia , lookup
History of electromagnetic theory wikipedia , lookup
Current source wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Ground loop (electricity) wikipedia , lookup
Electronic engineering wikipedia , lookup
Electromagnetic compatibility wikipedia , lookup
Three-phase electric power wikipedia , lookup
Fault tolerance wikipedia , lookup
Opto-isolator wikipedia , lookup
Electrification wikipedia , lookup
Overhead power line wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Electrical ballast wikipedia , lookup
Buck converter wikipedia , lookup
Electrical engineering wikipedia , lookup
Power engineering wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Electrician wikipedia , lookup
Surge protector wikipedia , lookup
History of electric power transmission wikipedia , lookup
Electrical substation wikipedia , lookup
Rectiverter wikipedia , lookup
Voltage optimisation wikipedia , lookup
Stray voltage wikipedia , lookup
Portable appliance testing wikipedia , lookup
Ground (electricity) wikipedia , lookup
Alternating current wikipedia , lookup
National Electrical Code wikipedia , lookup
Mains electricity wikipedia , lookup
2330 Level 2 Electrotechnical Technology (2330) Sample questions for multiple choice assessments Units 201, 202, 203, 205, 207, 209, 211, 213 and 215 www.cityandguilds.com October 2006 Version 2.1 (June 2007) About City & Guilds City & Guilds is the UK’s leading provider of vocational qualifications, offering over 500 awards across a wide range of industries, and progressing from entry level to the highest levels of professional achievement. With over 8500 centres in 100 countries, City & Guilds is recognised by employers worldwide for providing qualifications that offer proof of the skills they need to get the job done. City & Guilds Group The City & Guilds Group includes City & Guilds, ILM (the Institute of Leadership & Management) which provides management qualifications, learning materials and membership services, NPTC which offers land-based qualifications and membership services, and HAB (the Hospitality Awarding Body). City & Guilds also manages the Engineering Council Examinations on behalf of the Engineering Council. Equal opportunities City & Guilds fully supports the principle of equal opportunities and we are committed to satisfying this principle in all our activities and published material. A copy of our equal opportunities policy statement Access to assessment and qualifications is available on the City & Guilds website. Copyright The content of this document is, unless otherwise indicated, © The City and Guilds of London Institute 2007 and may not be copied, reproduced or distributed without prior written consent. However, approved City & Guilds centres and learners studying for City & Guilds qualifications may photocopy this document free of charge and/or include a locked PDF version of it on centre intranets on the following conditions: • centre staff may copy the material only for the purpose of teaching learners working towards a City & Guilds qualification, or for internal administration purposes • learners may copy the material only for their own use when working towards a City & Guilds qualification • the Standard Copying Conditions on the City & Guilds website. Please note: National Occupational Standards are not © The City and Guilds of London Institute. Please check the conditions upon which they may be copied with the relevant Sector Skills Council. Publications City & Guilds publications are available on the City & Guilds website or from our Publications Sales department at the address below or by telephoning +44 (0)20 7294 2850 or faxing +44 (0)20 7294 3387. Every effort has been made to ensure that the information contained in this publication is true and correct at the time of going to press. However, City & Guilds’ products and services are subject to continuous development and improvement and the right is reserved to change products and services from time to time. City & Guilds cannot accept liability for loss or damage arising from the use of information in this publication. City & Guilds 1 Giltspur Street London EC1A 9DD T +44 (0)20 7294 2800 F +44 (0)20 7294 2400 www.cityandguilds.com [email protected] Contents 1 About this document 3 2 Sample questions 4 2.1 Unit 201 Working effectively and safely in the electrotechnical environment (Stage 1) 5 2.2 Unit 202 Principles of electrotechnology (Stage 1) 2.3 Unit 203 Application of health and safety and electrical principles (Stage 2) 10 2.4 Unit 205 Installation (buildings and structures) 13 2.5 Unit 207 Electrical maintenance 16 2.6 Unit 209 Highway electrical systems 19 2.7 Unit 211 Installation, instrumentation and associated equipment 21 2.8 Unit 213 Panel building 23 2.9 Unit 215 Electrical machines repair and rewind 25 3 Answer keys 27 2330 Level 2 Electrotechnical Technology 7 1 This page is intentionally blank 2 2330 Level 2 Electrotechnical Technology 1 About this document This document contains sample multiple choice questions for the following on-line assessments within the Level 2 Certificate in Electrotechnical Technology. 201 202 203 205 207 209 211 213 215 Working effectively and safely in the electrotechnical environment (Stage 1) Principles of electrotechnology (Stage 1) Application of health and safety and electrical principles (Stage 2) Installation (buildings and structures) Electrical Maintenance Highway Electrical Systems Installing Instrumentation & Associated Equipment Panel Building Electrical Machines Repair and Rewind These sample questions will help you become familiar with the types of questions that might be asked in the examinations. Centres may decide to ask candidates to answer sample questions under exam conditions but how they are used is essentially at the discretion of the centre. Please note that these are sample questions and it is unlikely that the same questions will appear in the actual examinations. 2330 Level 2 Electrotechnical Technology 3 2 Sample questions 4 2330 Level 2 Electrotechnical Technology 2.1 Unit 201 Working effectively and safely in the electrotechnical environment (Stage 1) Q1 Q2 Q3 Q4 Q5 Which of the following documents is non-statutory a Health and Safety at Work Act b Electricity at Work Regulations c COSHH d BS 7671 Requirements for Electrical Installations. Prior to using an electric saw on a construction site, a user check finds that the insulation on the supply flex is damaged. The correct procedure would be to a replace the cord with a new one b report the damage to a supervisor after use c repair the cord with insulation tape d report the damage to a supervisor before use. When carrying out repairs to the base of a street lighting column it is essential to wear a a safety harness b high visibility clothes c gauntlets d high voltage clothing. First aid points are indicated using signs bearing a white cross on a a yellow background b blue background c red background d green background. The type of fire extinguisher which would not be suitable for flammable liquids is a dry powder b water c carbon dioxide d foam. 2330 Level 2 Electrotechnical Technology 5 Q6 Q7 Q8 Q9 CO2 fire extinguishers are indicated by the colour code a black b red c beige d blue. An independent regulatory body responsible for monitoring standards of electrical installation contractors is the a Electrical Institute Council b Institute of Electrical Engineers c National Electrical Contractors Institute Inspection Council d National Inspection Council for Electrical Installation Contractors. To ensure that a particular item of electrotechnical equipment meets a particular British Standard or BSEN Harmonised Standard, the best source of information would be the a manufacturer of the equipment b British Standards Institute c Institute of Electrical Engineers d supplier of the equipment. Using a scale of 1:50, a 10 mm measurement taken from a plan would be equal to an actual measurement of a 5 mm b 5 cm c 0.5 m d 5 m. Q10 Figure 1 Figure 1 shows the BS EN 60617 symbol for a 6 a one gang switch with arrow indicator b one gang one way pull cord switch c two way switch with on down d fireman’s switch. 2330 Level 2 Electrotechnical Technology 2.2 Unit 202 Principles of electrotechnology (Stage 1) Q1 Q2 Q3 Q4 The Tesla is the unit of a magnetic flux b molecular flux c magnetic flux density d molecular flux density. A single rotation of an alternator, intended to provide a 50 Hz supply frequency, will take a 2 ms b 20 ms c 50 ms d 5000 ms. An increase in current through a conductor will lead to a a decrease in conductor temperature b a decrease in conductor resistance c an increase in insulation resistance d an increase in conductor temperature. Four resistors having values of 2 Ω, 2 Ω, 5 Ω and 20 Ω are connected in a parallel circuit arrangement. The total resistance of this circuit is a 0.8 Ω b 1.25 Ω c 29 Ω d 400 Ω. 2330 Level 2 Electrotechnical Technology 7 Q5 Where P = V I. The value V can be determined using a V = _I_ P b V= PI c V= P-I d V = _P_ I Q6 Q7 Q8 Q9 8 A mass of 20 kg is to be raised by a hoist 2 m in 30 seconds. Assuming no losses, the power required to raise this load is a 13.08 Watts b 196.2 Watts c 392.4 Watts d 1200 Watts. The white or grey pvc outer layer of a twin and cpc flat thermoplastic (pvc) cable is the a conductor b insulation c conductor d sheath. The purpose of a bonding conductor is to provide a an earth fault path b an equal potential zone c short circuit protection d overload protection. A 110 V, centre tapped earth, reduced low voltage supply for power tools provides a voltage of a 25 V between live conductors b 55 V to earth c 110 V to earth d 12 V SELV. 2330 Level 2 Electrotechnical Technology Q10 A particular extension lead used on a construction site is coloured yellow to a indicate its mechanical stress properties b enable it to be seen in the dark c indicate the supply voltage to it d enable it to be to be identified as suitable for site use. 2330 Level 2 Electrotechnical Technology 9 2.3 Unit 203 Application of health and safety and electrical principles (Stage 2) Q1 The five main stages of the risk assessment procedure are: 1 identify 2 evaluate 3 record 4 implement 5 review The order in which they should be carried out is Q2 Q3 Q4 10 a 1, 3, 2, 4, 5 b 1, 2, 3, 4, 5 c 2, 1, 4, 3, 5 d 2, 3, 1, 4, 5. Before any work is done within an electrical installation, the first procedure would be to a carry out a risk assessment b turn off the main switch c remove all components d install temporary supplies. On a large construction site, inductions are carried out for new members of staff in order to inform them of the a location of the canteen b requirements within BS 7671 c fire safety procedure d location of the nearest wholesaler. A suitable means of recording the number of visitors on a large construction site is by the use of a a daywork sheet b timesheet c take off sheet d visitors book. 2330 Level 2 Electrotechnical Technology Q5 Which of the following would be the safest method of erecting a tower scaffold? Q6 In order to prove safe isolation of an electrical circuit, it is essential to use Q7 Q8 Q9 a a multi-meter b an insulation resistance tester c an approved voltage indicator d a low reading ohm meter. In order to determine the amount of accessories required for a particular contract, the best method would be to use the layout drawings and a a site diary b take off sheet c daywork sheet d time sheet The ratio of the true power to apparent power in an a.c circuit is the a power consumption b harmonic current c power factor d reactive power Which of the following is a transmission voltage? a 400 kV b 33 kV c 400 V d 230 V. 2330 Level 2 Electrotechnical Technology 11 Q10 12 If a circuit protective device requires 200 A in order to disconnect in the required time, the overall impedance of the earth fault path for a 230 V circuit protected by the device must not exceed a 0.86 Ω b 1.15 Ω c 2.15 Ω d 2.30 Ω. 2330 Level 2 Electrotechnical Technology 2.4 Unit 205 Installation (buildings and structures) Q1 Q2 Q3 Q4 Which of the following is a non-statutory regulation a Electricity at Work Regulations b Health and Safety at Work Act c Electricity Safety, Quality and Continuity Regulations d BS 7671 Requirements for Electrical Installations. For a drawing having a scale of 1:50, a wall 10 m long would be drawn to a length of a 10 mm b 20 cm c 50 cm d 10050 mm. The maximum operating temperature for a thermoplastic (pvc) insulated cable with copper conductors is a 60 OC b 70 OC c 105 OC d 160 OC A circuit wired in 1.5 mm2 thermoplastic (pvc) twin with cpc cable is protected by a 16 A device and is used to supply a 230 V 3 kW water heater. If the cable has a rated voltage drop of 29 mV/A/m and the circuit is 24 m long, the actual voltage drop will be a 2.08V b 9.07V c 11.14V d 69V. 2330 Level 2 Electrotechnical Technology 13 Q5 Q6 Q7 Q8 Q9 14 A non maintained emergency light is classified as NM3. This means that the luminaire will illuminate during a normal conditions then automatically switch off after three hours b any power failure for up to three hours c both normal and power failure conditions then automatically switch off after three hours d power failures that last longer than three hours but not shorter than three hours. An earthing arrangement that has a PEN conductor is a TN-C-S b TN-S c TT d IT. A residual current device will disconnect under a short circuit conditions only b both earth fault and short circuit conditions c earth fault conditions only d overload conditions only. The most suitable item of equipment to mark a straight line in order to install a horizontal conduit over a distance of 4 m is a a plumb line b spirit level c steel tape d chalk line A 50 mm x 50 mm steel trunking has a tabulated space factor of 1037. If the tabulated factor for PVC cable having a cross sectional area of 6 mm2 is 21.2, the maximum number of these cables that can be installed into the trunking is a 47 b 48 c 49 d 50 2330 Level 2 Electrotechnical Technology Q10 The four electrical tests that should be carried out on a new ring final circuit before it is energised are a continuity of protective conductors, continuity of ring final circuits, insulation resistance and polarity b continuity of ring final circuits, insulation resistance, polarity and earth fault loop impedance c insulation resistance, polarity, earth fault loop impedance and continuity of protective conductors d polarity, earth fault loop impedance, continuity of protective conductors and continuity of ring final circuits. 2330 Level 2 Electrotechnical Technology 15 2.5 Unit 207 Electrical maintenance Q1 Q2 Q3 Q4 16 The Electricity at Work Regulations state that electrical equipment must be maintained to prevent danger. Electrical equipment is defined as all small items of battery-powered equipment up to and including overhead power lines rated at a 230V b 400V c 33kV d 400kV. In order to prevent danger during maintenance operations, a voltage warning notice is required on all electrical accessories where a voltage is present b the voltage exceeds 230V and such voltage would not be expected c the voltage exceeds 400V d the voltage is below 230V. In order to facilitate maintenance of a complex electrical system, the sequence of control for isolation can be best shown using a a block diagram b layout drawing c circuit diagram d bar chart. Balancing loads over three phases will reduce a phase currents b earth faults c neutral currents d overloads. 2330 Level 2 Electrotechnical Technology Q5 Q6 Q7 Q8 Q9 Once a low pressure mercury vapour lamp has lit, the purpose of the choke/ballast unit is to a discharge voltage b correct power factor c suppress radio interference d limit lamp current. Certain discharge luminaires mounted above rotating machine can give the appearance that the machine is at a standstill. This effect is known as a stroboscopic effect b robotic effect c rotor effect d telescopic effect. Guidance on regular inspection and testing of portable appliances can be found in a BS 7671 Requirements for Electrical Installation b IEE Guidance Note 3 Inspection and testing c IEE Code of Practice for In-Service Inspection and Testing of Electrical Equipment d IEE On Site Guide. In order to understand the operating procedure for a particular item of equipment, the best source of information would be the a company sales representative b manufacturers’ manual c manufacturers’ catalogue d circuit diagram. When carrying out maintenance work on a distribution board in a busy walkway, it is advisable to protect others by the use of a a warning sign b safety barrier c temporary bollard d audible warning device. 2330 Level 2 Electrotechnical Technology 17 Q10 18 Low pressure mercury vapour lamps should be disposed of by a throwing in a skip b putting in a glass recycle point (clear glass only) c using a suitable lamp crusher d putting in the refuse bins which are collected weekly. 2330 Level 2 Electrotechnical Technology 2.6 Unit 209 Highway electrical systems Q1 Q2 Q3 Q4 Q5 Which of the following normally form part of a highway electrical system? a Current transformers and photo electrical control units b Voltage transformers and RCDs c Ignitors and transformers d Power factor meter and isolators Which of the following is a non-statutory document? a The New Roads and Street Works Act b The Electricity Safety, Quality and Continuity Regulations 2002 c BS 7671 d The Electrical Equipment (Safety) Regulations Which of the following is a statutory document applicable to operatives carrying out installation and maintenance of highway electrical equipment? a The Laying of Cables in Public Highways b H.S.E guidance H.S.G 47 (Avoiding danger from underground and overhead services) c The Personal Protective Equipment at Work Regulations d Electricity Association G39/1 It is necessary to avoid skin contact with quartz lamps, as it a reduces the life of the lamp b could cause burns c generates excessive heat d lengthens lamp working life. Voltage indication devices need to be proved to ensure a that the lamp has not gone b that the highway furniture has been installed correctly c safe working conditions d the correct operation of street furniture. 2330 Level 2 Electrotechnical Technology 19 Q6 Q7 Q8 Q9 Q10 20 Relevant information for re commissioning street furniture can be found in a IEE Guidance Notes 7 b Works instructions c The Electricity Supply Regulations d The Petroleum (Consolidation) Act 1928. Instruments should be regularly calibrated to a support local industry b ensure accuracy when testing c ensure operative is up to date d provide a training exercise for operatives. To facilitate safe isolation, voltage indicating devices a must comply with BS 7671 b are used to prove the circuit was dead only c are used to prove the circuit was alive only d are “proved” prior to and “re-proved” after isolation. Which legislation states the need to avoid live working unless unreasonable in all circumstances? a BS 7671 b Guidance Notes 3 c On-Site Guide d The Electricity at Work Regulations Which of the following lamps would not normally form part of a highway electrical system? a Low pressure mercury (T8-T12) b Low pressure mercury (MBF) c Metal halide (MBI) d Incandescent Lamp (100W) 2330 Level 2 Electrotechnical Technology 2.7 Unit 211 Installation, instrumentation and associated equipment Q1 Q2 Q3 Q4 Q5 Which of the following is a statutory piece of legislation? a BS 7671 b IEE Guidance Notes c Electricity at Work Regulations d IEE On-Site Guide Which of the following has an impact upon earthing? a BS EN 60439-01 b BS 4491 c BS 4444 d BS EN 60898 When an ammeter is connected in a circuit it is essential that it a has a very low resistance b has a very high resistance c is connected across the supply d is connected across the load. When a voltmeter is connected in a circuit it is essential that it a has a very low resistance b has a very high resistance c is connected in series with the supply d is connected in series with the load. To facilitate ease of installation and assembly of equipment reference is made to a BS 7430 b manufacturer’s catalogues c GS 38 d data charts. 2330 Level 2 Electrotechnical Technology 21 Q6 Q7 Q8 Q9 Q10 22 Electrostatic sensitive equipment, in transit, need not be protected against damage from a high temperature b dust and fibres c moisture ingress d day light. The purpose of a method statement is to a ensure compliance with BS 7671 b identify a safe working practice c provide a training document for staff d provide instructions to be followed at all times. The purpose of a visual inspection is to ensure compliance with BS 7671, Section a 601 b 712 c 413 d 314. Which of the following has an adverse effect on installed equipment? a Eddy current damping b Air damping c Ambient temperature d Operating temperature Which of the following is not a factor which would affect the type of termination? a Circuit design current b Physical space around terminations c Presence of solid foreign bodies d Size of conductor 2330 Level 2 Electrotechnical Technology 2.8 Unit 213 Panel building Q1 Q2 Q3 Q4 Q5 To ensure safe isolation, voltage indicating devices a must comply with BS 7671 b are used to prove the circuit dead only c are used to prove the circuit was alive only d must be “proved” prior to and “re-proved” after isolation. A moving coil meter is not used on an ac circuit because a it cannot read very small variations b the direction of the deflection depends upon the direction of the current c it is non linear d it does not use the damping effect. A common type of cable termination used for ribbon cables in panel building is a pin b lug c insulation displacement d screw. The purpose of a switch is to open or close a circuit a in the event of a fault current b under load conditions c under overload conditions d automatically after a fault has been repaired. Which of the following are appropriate tests for a completed panel? a Flash testing of components b Insulation resistance and polarity c Inspection of conductors for current carrying capacity d Identification of conductors 2330 Level 2 Electrotechnical Technology 23 Q6 Q7 Q8 Q9 Q10 24 Which of the following is statutory? a BS 7671 b On-Site Guide c Electricity at Work Regulations d GS 38 What degree of protection is specified for protection against a BS finger? a IP4XB b IP5XB c IP6XB d IPXXB BS 7671 provides appropriate advice on a heights of panels b design of panels c environmental conditions d instrumentation. A device with a BS EN number has been a agreed for use only within the UK b agreed for operational use within the EU c standardised for all operational uses only in the UK d standardised for use in the EU. An isolator built into a panel is used for a normal load switching b fault load switching c short circuit protection d no load switching. 2330 Level 2 Electrotechnical Technology 2.9 Unit 215 Electrical machines repair and rewind Q1 Q2 Q3 Q4 Q5 Particular starting arrangements are used when a motor has a rating greater than a 370 micro watts b 0.37 watts c 37 watts d 370 watts. With a star-delta starter the windings are brought out to a terminal box. The voltage applied to the windings at starting is a VL ÷ √3 b VL x √3 c VPhase ÷ √3 d VPhase x √3 . When the field windings of an electrical machine are not connected to its own armature, it is known as a Self- excited b Polyphase c Separately-excited d Synchronous. In a shunt-wound motor the field coil is connected in a series with the armature b series with the motor c parallel with the armature d parallel with the motor. If a motor is required to start against a large starting current it is usual to use a direct on line starter b face plate starter c step down centre tapped starter d rotor resistance starter. 2330 Level 2 Electrotechnical Technology 25 Q6 Q7 Q8 Q9 26 The usual method of insulating core laminations is a low reluctance silicon steel b surface oxidization c high frequency air cores d cellulose paper. One method of insulating windings is to use a shelac b high reluctance silicon steel c low frequency dust cores d pvc. A single phase double-wound transformer consists of a a single core mounted winding b a winding that carries the difference between Ip and Is c a single solid core d two electrically separated coils. In a star connected three phase transformer the a three phases are connected together at the start point b three phases are separate c neutral conductor is connected to a single phase d neutral conductor is electrically separated. 2330 Level 2 Electrotechnical Technology 3 Answer keys Unit 201 Q1 – D Q2 – D Q3 – B Q4 – D Q5 – B Q6 – A Q7 – D Q8 – A Q9 – C Q10 – B Unit 205 Q1 – D Q2 – B Q3 – B Q4 – B Q5 – B Q6 – A Q7 – C Q8 – D Q9 – B Q10 – A Unit 211 Q1 – C Q2 – C Q3 – A Q4 – B Q5 – D Q6 – D Q7 – B Q8 – B Q9 – C Q10 - C Unit 202 Q1 – C Q2 – B Q3 – D Q4 – A Q5 – D Q6 – A Q7 – D Q8 – B Q9 – B Q10 – C Unit 207 Q1 – D Q2 – B Q3 – A Q4 – C Q5 – D Q6 – A Q7 – C Q8 – B Q9 – B Q10 – C Unit 213 Q1 – D Q2 – B Q3 – C Q4 – B Q5 – B Q6 – C Q7 – D Q8 – C Q9 – D Q10 - D Unit 203 Q1 – B Q2 – A Q3 – C Q4 – D Q5 – D Q6 – C Q7 – B Q8 – C Q9 – A Q10 – B Unit 209 Q1 – C Q2 – C Q3 – C Q4 – A Q5 – C Q6 – B Q7 – B Q8 – D Q9 – D Q10 – D Unit 215 Q1 – D Q2 – A Q3 – C Q4 – C Q5 – D Q6 – B Q7 – A Q8 – D Q9 – A 2330 Level 2 Electrotechnical Technology 27 This page is intentionally blank 2330 Level 2 Electrotechnical Technology 1 Published by City & Guilds 1 Giltspur Street London EC1A 9DD T +44 (0)20 7294 2468 F +44 (0)20 7294 2400 www.cityandguilds.com City & Guilds is a registered charity established to promote education and training 2 2330 Level 2 Electrotechnical Technology