* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download G / E-Series Motor Protection Relay Product Features Specifications
Electric power system wikipedia , lookup
Electromagnetic compatibility wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Power inverter wikipedia , lookup
Stepper motor wikipedia , lookup
Power engineering wikipedia , lookup
Electrical ballast wikipedia , lookup
Mercury-arc valve wikipedia , lookup
History of electric power transmission wikipedia , lookup
Chirp spectrum wikipedia , lookup
Current source wikipedia , lookup
Electrical substation wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Portable appliance testing wikipedia , lookup
Utility frequency wikipedia , lookup
Protective relay wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Opto-isolator wikipedia , lookup
Buck converter wikipedia , lookup
Ground (electricity) wikipedia , lookup
Surge protector wikipedia , lookup
Power electronics wikipedia , lookup
Distribution management system wikipedia , lookup
Voltage optimisation wikipedia , lookup
Stray voltage wikipedia , lookup
Three-phase electric power wikipedia , lookup
Electrical wiring in the United Kingdom wikipedia , lookup
Mains electricity wikipedia , lookup
G / E-Series Motor Protection Relay Product Features ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● Din sized enclosure : 96 x 96 x 85mm LED indication for relay status Seperate 7 segment window with high brightness red LED display for values and its corresponding parameters . Auto / Manual Operation Resetting facility at front panel is available in manual mode Type of fault displayed through 7 segment display during unhealthy condition . Trip delay time can be set indivisually for each parameter . Parameters can be bypassed as per users choice Relay can be configured to have NO or NC status during healthy condition . Monitors and trips the load on occurance of any below mentioned fault condition aftera preset time delay .1.Phase failure 2. Phase sequence 3.Phase unbalance 4.Under and Over Voltage 5. Under and Over Current 6.Under and Over frequency 7.earth leakage c User settable In-rush. Display all the 3 phase voltages(Line to Line and Line to Neutral)3 phase currrents,frequency in a scrolling fashion during healthy condition . User settable earth leakage limits. CT primary can be programmed up to 2500 in steps of 5. CT secondary will be factory set for 5. Display the type of fault in manual mode till manual key is pressed. Specifications Model MPR-E1 Function Phase Unbalance, Phase Reversal, Phase Failure, Under & Over Voltage, Under & Over Current, Under & Over Frequency Monitor and Control, Earth leakage protection Rated supply voltage 415V AC, 3 phase, 4 wire Rated frequency 50Hz ± 10% Power consumption 5VA / 1W Input Current Current Input (AR,AY,AB) Ib=5A Voltage ± 4V of display value Current ± 5% of Ib ± 1 digit (Ib=5A) Frequency ± 2% of FS ± 1 digit Trip time ± 1% of set delay ± 2 sec Earth leakage current ± 500mA of setting accuracy Trip setting Phase Unbalance : 1 to 20% (Adj.) Under Voltage : 5 to 100V AC Over Voltage : 5 to 100V AC Over Current : 105% to 800% Under Current : 20%* to 95% Over Frequency : 2 to 5Hz Under Frequency : 2 to 5Hz Earth leakage Current sensitivity range : 1 to 8A Minimum sensing current* 0.5A Maximum setting current 5A (Above 5A > Ext. CT can be used, CT setting max. 2500 / 5 Amp in steps of 5) Trip time delay 1 to 250 secs settable for UB, OV, UV, OC, UC Earth leakage trip time delay 5 sec Earth leakage Phase failure trip time delay < 5 sec Phase reverse trip time delay Instantaneous Frequency trip time delay Instantaneous Recovery time 2 sec Min Power On delay 10 sec Max. Inrush current delay 1 to 60sec Settable Mode of Operation Auto / Manual Core Balance Current Transformer Type Toriodal core Control Output 1 c/o rated for 10A @ 250V AC / 28V DC resistive load Recovery time 2 sec min Ambient temperature Operation: -100C to +550C, Storage: -250C to +800C Humidity Max. 85% RH @ 400C Service life (under no load) 106 operations minimum Electrical life (under full load) 105 operations minimum Rated frequency of operation 1800 ± 5% operations per hour max Insulation resistance >100M ohms @ 500V DC Model MPR-E1 Di-electrical strength 1. 2.5KV AC, 50Hz for 1minute. (Between current carrying and non-current carrying parts). 2. 1.5KV AC, 50Hz for 1minute. (Between contacts and control circuit). 3. 750V AC, 50Hz for 1minute. (Between non-continuous contacts of the relay). Electrical connection Screw type terminals with self lifting clamps Mode of operation Manual / Auto CBCT Size internal Diameter Circular 75 / 100 mm Dimension (over-all) 96 x 96 x 97.5mm (W x H x D) * Applicable for more than 2.5 Amps nominal current Connections Dimensions Accessories Instruction Manual -----1No. RC Filter -----1No. Hints On Correct Use Tools and Fasteners Kindly use star – type screw driver for tightening the screws. NOTE: Installation should include a disconnecting device, like switch or circuit breaker, with clear ON/OFF markings, to turn-off the auxiliary supply (control power).The disconnecting device should be within the reach of the equipment and the operator Caution ● ● ● ● ● ● ● ● ● ● ● Apply appropriate personal protective equipment(PPE) and follow safety work practices Only qualified electrical workers should install this equipment. Such work should be performed only after reading this entire set of instructions. If the equipment is not used in the manner specified by the manufacturer, the protection provided by the equipment may be impaired. NEVER work alone. Turn OFF all power supplying the energy meter and the equipment in which it is installed before working on it. The successful operation of this equipment depends upon proper handling, installation and operation. Neglecting fundamental installation requirements may lead to personal injury as well as damage to electrical equipment or other property. NEVER bypass external fusing. NEVER apply the voltages at Program Lock and Auto Reset terminals. Before performing Dielectric or Megger testing on any equipment in which the monitoring device is installed, disconnect all the input and output wires to the monitoring device. High voltage testing may damage electronic components contained in the monitor The monitoring device should be installed in a suitable electrical enclosure. EAPL is not responsible for any consequential damages arising out of use of our products, though the technology is cautiously chosen and implemented like any other well designed good electric device.