• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Looking through walls and around corners with
Looking through walls and around corners with

Three Lasers Converging at a Focal Point : A Demonstration
Three Lasers Converging at a Focal Point : A Demonstration

... 1. Clear a space on a table. Set up three lasers next to each other so they will produce parallel beams of light. The lasers need to be close together so they all pass through the lens. There are two ways to accomplish this. One is to not use the supports and use a rubber band to hold the lasers tog ...
Progess 11-4-13.pdf
Progess 11-4-13.pdf

Presentation
Presentation

... 17. Mariampillai, A., et al. (2008). "Speckle variance detection of microvasculature using swept-source optical coherence tomography." Opt Lett 33(13): 1530-1532. 18. Sudheendran, N., et al. (2011). "Speckle variance OCT imaging of the vasculature in live mammalian embryos." Laser Physics Letters 8( ...
may10-94 as a Word 6.0 doc - Lyle School of Engineering
may10-94 as a Word 6.0 doc - Lyle School of Engineering

Spider Silk: The Mother Nature`s Biological Superlens
Spider Silk: The Mother Nature`s Biological Superlens

... To summarise, this paper verified that the minor ampullate spider silk, spun from the Nephila edulis spider, has the properties to perform as an optical superlens by utilising photonic nanojets to carry the surface information at a highspatial-frequency, which can resolve 100-nm objects and patterns ...
Optical Computers (Erin Raphael, 2006)
Optical Computers (Erin Raphael, 2006)

1. Which of the following statement are true about "LED life" term?
1. Which of the following statement are true about "LED life" term?

... LED life refers to time duration of the charge carriers in the active region (lifetime of the carriers) LED life increase if Iforward increase 2. Which are the main parameters of an LED that are affected by temperature? Luminous intensity (brightness) ...
Joule Expansion Imaging Techniques on Microlectronic Devices
Joule Expansion Imaging Techniques on Microlectronic Devices

4.8 Acceptance Angle and Numerical Aperture
4.8 Acceptance Angle and Numerical Aperture

... The grid slide or screen and ruler can be used to measure diameters. The edges of the cone of light may appear fuzzy so there will be an error introduced into your measurements. Measurement of the edges is an approximation to the notion of Full Width Half Maximum (FWHM). This is how light boundaries ...
Investigation of nanoscale structural alterations of cell nucleus as an
Investigation of nanoscale structural alterations of cell nucleus as an

... various versions of quantitative phase microscopy and digital holographic microscopy (DHM) [18]. The light interference effect is well known to detect changes in optical path length even at sub-nanometer sensitivity. The second form is based on the analysis of Fourier space (or K-space, the conjugat ...
d) Laser system and its applications Question Bank
d) Laser system and its applications Question Bank

Aperture interference and the volumetric resolution of light field
Aperture interference and the volumetric resolution of light field

Time-of-flight optical ranging system based on time
Time-of-flight optical ranging system based on time

... system and was designed to permit maximum flexibility in the investigation of several different optical configurations. The optical axis defined by the V grooves lies 10 mm above the surface of the base plate and permits movement of the optical components only by rotation about or translation along ...
Preview of “ZEISS Microscopy Online ...opy Basics | Objectives”
Preview of “ZEISS Microscopy Online ...opy Basics | Objectives”

Understanding Microscopy And Filtering Techniques
Understanding Microscopy And Filtering Techniques

... 10mm of length and adapts the M26 thread to a C-thread). An additional 76.5mm of space between the tube lens and objective is optimal, but it is common to only use about 56.5mm of space between #55-743 and #58-329 since each adapter adds about 10mm of space. With this 56.5mm of space, use extension ...
Optical laser beam scanner lens relay system
Optical laser beam scanner lens relay system

... with standard, i.e. commonly available lenses. Nevertheless, a very good performance can be obtained with a little bit of care in the design. Even a very simple design using achromats is adequate, although significantly improved performance can be obtained if meniscus lenses are added. The general r ...
Single camera spectral domain polarization
Single camera spectral domain polarization

High spatial resolution performance of a triple Fabry–Pérot filtergraph
High spatial resolution performance of a triple Fabry–Pérot filtergraph

Generation of relativistic intensity pulses at a kilohertz
Generation of relativistic intensity pulses at a kilohertz

BPM Blatt 7
BPM Blatt 7

The Pathologist`s Microscope
The Pathologist`s Microscope

Reflection-mode scanning near-field optical microscopy: Influence
Reflection-mode scanning near-field optical microscopy: Influence

Introduction to Fluorescence Spectroscopies I. Theory
Introduction to Fluorescence Spectroscopies I. Theory

10-GHz Bandwidth RF Spectral Analyzer With MHz Resolution
10-GHz Bandwidth RF Spectral Analyzer With MHz Resolution

... leading to a number of frequency channels equal to 10 000. The inset in Fig. 3(a) is an illustration of this resolution. The upper trace corresponds to the probing of two engraved tones MHz/ms. separated by 1.2 MHz with a chirp value The two peaks are well resolved. The other quadrature of the demod ...
< 1 ... 37 38 39 40 41 42 43 44 45 ... 61 >

Super-resolution microscopy

Super-resolution microscopy is a form of light microscopy. Due to the diffraction of light, the resolution of conventional light microscopy is limited as stated by Ernst Abbe in 1873. A good approximation of the resolution attainable is the full width at half maximum (FWHM) of the point spread function, and a precise widefield microscope with high numerical aperture and visible light usually reaches a resolution of ~250 nm.Super-resolution techniques allow the capture of images with a higher resolution than the diffraction limit. They fall into two broad categories, ""true"" super-resolution techniques, which capture information contained in evanescent waves, and ""functional"" super-resolution techniques, which use clever experimental techniques and known limitations on the matter being imaged to reconstruct a super-resolution image.True subwavelength imaging techniques include those that utilize the Pendry Superlens and near field scanning optical microscopy, the 4Pi Microscope and structured illumination microscopy technologies like SIM and SMI. However, the majority of techniques of importance in biological imaging fall into the functional category.There are two major groups of methods for functional super-resolution microscopy: Deterministic super-resolution: The most commonly used emitters in biological microscopy, fluorophores, show a nonlinear response to excitation, and this nonlinear response can be exploited to enhance resolution. These methods include STED, GSD, RESOLFT and SSIM. Stochastic super-resolution: The chemical complexity of many molecular light sources gives them a complex temporal behaviour, which can be used to make several close-by fluorophores emit light at separate times and thereby become resolvable in time. These methods include SOFI and all single-molecule localization methods (SMLM) such as SPDM, SPDMphymod, PALM, FPALM, STORM and dSTORM.On October 8th, 2014, the Nobel Prize in Chemistry was awarded to Eric Betzig, W.E. Moerner and Stefan Hell for ""the development of super-resolved fluorescence microscopy,"" which brings ""optical microscopy into the nanodimension"".
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report