* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download A PRELIMINARY DESIGN FOR A SMALL
Survey
Document related concepts
Identical particles wikipedia , lookup
Magnetic monopole wikipedia , lookup
Casimir effect wikipedia , lookup
Relativistic quantum mechanics wikipedia , lookup
Canonical quantization wikipedia , lookup
Future Circular Collider wikipedia , lookup
Aharonov–Bohm effect wikipedia , lookup
Antiproton Decelerator wikipedia , lookup
ATLAS experiment wikipedia , lookup
Theoretical and experimental justification for the Schrödinger equation wikipedia , lookup
Elementary particle wikipedia , lookup
Quantum vacuum thruster wikipedia , lookup
Electron scattering wikipedia , lookup
Particle accelerator wikipedia , lookup
Transcript
A PRELIMINARY DESIGN FOR A SMALL CYCLOTRON Barry King, Jake Roloson, Sharon Tuminaro, Mark Yuly Department of Physics One Willard Avenue Houghton College Houghton, NY 14744 1. Abstract A small cyclotron is being constructed using a 0.5 T permanent magnet, with 15.2 cm (6.0 inch) diameter pole faces and 3.8 cm (1.5 inch) pole separation. An acceleration chamber containing a single brass RF electrode is being developed. In this design magnetic field strength may be modified by adjusting the pole separation using iron pole pieces, which are sealed to the chamber using high vacuum grease. The chamber will be filled with low pressure hydrogen gas which will be ionized by electrons released by a cathode located at the center of the chamber. The required 3.6 MHz to 11.5 MHz RF power will be supplied by a commercial RF amplifier. A liquid nitrogen cold trap with a diffusion pump backed by a forepump will be used to evacuate the chamber. Energies between 37.5 keV and 87.7 keV for protons and 18.7 keV and 43.8 keV for deuterons should be obtained. 2. Introduction The cyclotron is a magnetic resonance accelerator. The first cyclotron was built in 1930 by the late Ernest O. Lawrence with help from M. S. Livingston. It uses the principle of resonance acceleration, that is the charged particles move outward in a spiral, traversing a “D” shaped electrode in resonance with an oscillating electric field. As can be seen in figure 1, the particles gain energy on each cycle, resulting in a larger orbital radius. The advantage of a cyclotron is its compact size and the low voltages used. The motivation is to produce a low energy particle accelerator to use in a small nuclear physics laboratory. 3. Theory A charged particle will move in a circle when traveling in magnetic field perpendicular to its orbit. The centripetal acceleration is supplied by the Lorentz force, yeilding: mv 2 qvB r where q is the charge, B is the magnetic field, and m is the mass, r is the radius and v is the speed of the particle. The frequency with which the particle revolves is given by v qB f 2r 2m The beauty of the cyclotron design is the independence of the frequency on the location of the particle and its speed. In this way it is possible to connect a hollow copper electrode to a RF amplifier with fixed frequency defined above. Thus on each successive orbit, the particle will receive a “kick.” If we look at the classical definition of kinetic energy: mv 2 T 2 we find that q 2 B2 R 2 T 2m where R is the final radius of the particle. 4. Magnetic Field The magnetic field is uniform ( 0.493 T ) to within one percent, out to a radius of 6.19 cm ( Figure 3 - Solid Line ). The RF electrode radius is 7.14 cm ( Figure 3 – Dashed Line ), allowing us to use the full uniform region of the field. The moveable faraday cup allows us to collect the particles before entering the non-uniform field and measure the beam current. 5. Vacuum System A liquid nitrogen cold trap and diffusion pump backed by a rotary forepump will evacuate the acceleration chamber. The vacuum chamber will be attached to the pumps with a bellows to allow the chamber to be positioned in the magnetic field. The valves are used to allow the vacuum chamber to be worked on without letting air into the rest of the system, and then to be roughed down and re-evacuated. LN2 Trap – Liquid nitrogen cools any molecules in the trap, and prevents them from obtaining enough kinetic energy to escape the trap. Diffusion Pump – Oil is heated in the bottom of the pump, and then diffused into the upper section where it is cooled by water, and when it descends it pulls gas molecules that have attached to it. Electronics – The electronics are designed such that the diffusion pump cannot be turned on unless the forepump is turned on. The power supplied to the diffusion pump heater is controlled by a variac, and is monitored by the volmeter and ammeter shown in figure 5. 6. Chamber Design The chamber was designed with a single RF electrode, powered by an RF amplifier through a feedthrough in the chamber wall. Copper pipes are attached to the side walls of the chamber to allow for gas intake and evacuation by the vacuum pumps. A small filament releases electrons which ionize the gas in the center of the chamber. A 5.08 cm x 1.00 cm window attached to the chamber wall will allow observation of the interior of the chamber. Finally, a faraday cup attached to a bellows valve opposite the RF electrode will collect the particles. A retarding grid attached to the front of the faraday cup will eliminate loss of secondary electrons. The overall design can be seen in Figure 6. The central chamber and RF electrode will be made of brass, while the sealing plates, either made of iron or aluminum, will be attached with vacuum grease ( Figure 8 ). 7. Conclusion The vacuum system is nearly finished, and we are currently in the initial phase of constructing the chamber. The gray iron plates will strengthen the field of our magnet and may allow us to obtain higher energies. Although this machine will only generate 18.7 keV deuterons, it might be possible to use the H2(d,n)He3 reaction to yield neutrons with energies of 2.61 MeV. We could then place a deuterium target in our faraday cup that would yield a mono-energetic neutron source. The advantage to this is, while charged particles would need to be extracted, the neutrons will not interact with the magnetic field or chamber.