Survey
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Deoxyribozyme wikipedia , lookup
Secreted frizzled-related protein 1 wikipedia , lookup
Artificial gene synthesis wikipedia , lookup
Cre-Lox recombination wikipedia , lookup
Molecular cloning wikipedia , lookup
DNA vaccination wikipedia , lookup
Cell culture wikipedia , lookup
Transformation (genetics) wikipedia , lookup
List of types of proteins wikipedia , lookup
Cell-penetrating peptide wikipedia , lookup
Leading Developer and Manufacturer of In Vivo and DNA Transfection Kits, Transfection Reagents and Electroporation Delivery Products Products > H9c2 Transfection Reagent (Embryonic Myocardium) Altogen Biosystems offers the H9c2 Transfection Reagent among a host of 100+ cell line specific In Vitro Transfection Kits. H9c2 Transfection Reagent is an advanced cationic lipid formulation based reagent, and it has been developed to provide high transfection efficiency with H9c2 cells. This cell line is a good host for studying mammalian heart tissue. When cultured in vitro, H9c2 cells are a monolayer and adhere to the surface of the culture flask. Other applications include drug discovery, gene expression studies, molecular and cell biology research applications. Purchase H9c2 Transfection Kit at www.Altogen.com Altogen Biosystems 848 Rainbow Blvd #823 Las Vegas NV 89107 USA Telephone 702 349 6103 Fax 702 989-0841 email [email protected] Leading Developer and Manufacturer of In Vivo and DNA Transfection Kits, Transfection Reagents and Electroporation Delivery Products H9c2 Transfection Reagent (Embryonic Myocardium) H9c2 Cell Line Description and Applications Products > H9c2 Cells lonza.com The H9c2 cell line is a sub clone of the embryonic BD1X heart tissue taken from a rat (Rattus norvegicus) by B. Kimes and B. Brandt. The H9c2 cell line has characteristics of skeletal muscle and also displays myoblast morphology. The H9c2 cell line also expresses acetylcholine receptors. This cell line is particularly useful tool for studying mammalian heart tissue as well in varying areas of research within the fields of molecular and cellular biology. H9c2 is also effective as a transfection host. Altogen Biosystems 848 Rainbow Blvd #823 Las Vegas NV 89107 USA Telephone 702 349 6103 Fax 702 989-0841 email [email protected] Leading Developer and Manufacturer of In Vivo and DNA Transfection Kits, Transfection Reagents and Electroporation Delivery Products H9c2 Transfection Reagent (Embryonic Myocardium) H9c2 Transfection Protocol Products > 1. Plate 10,000 - 15,000 H9c2 cells per well in 0.5 ml of complete growth medium 12–24 hours prior to transfection 2. Wash with 1xPBS and add 0.5 ml of fresh growth medium 3. Prepare transfection complexes by mixing 40 µl of serum-free medium, 5.5 µl of transfection reagent, and • 750 ng DNA (or mRNA), or • 30 nM - 50 nM of siRNA (or microRNA) *Referred to a final volume including growth medium 4. Incubate transfection complexes at RT for 15 - 30 minutes 5. Optional: Add 2 µl of Complex Condenser. This reagent reduces the size of transfection complex, therefore increasing transfection efficiency; however it may increase cell toxicity 6. Add prepared transfection complexes to 0.5 ml of complete growth medium with H9c2 cells (from step 2) 7. Incubate cells at 37ºC in a humidified CO2 incubator 8. Assay for phenotype or target gene expression 48 - 72 hours after transfection Optional: Transfection efficiency can be increased by addition of Transfection Enhancer reagent. Add 2 µl of Transfection Enhancer reagent 12-24 hours after transfection If the viability of H9c2 cells being transfected is affected at 16 - 24 hours post-transfection, the level of cytotoxicity can be decreased by changing the growth medium and eliminating redundant exposure of cells to transfectant Altogen Biosystems 848 Rainbow Blvd #823 Las Vegas NV 89107 USA Telephone 702 349 6103 Fax 702 989-0841 email [email protected] Leading Developer and Manufacturer of In Vivo and DNA Transfection Kits, Transfection Reagents and Electroporation Delivery Products H9c2 Transfection Reagent (Embryonic Myocardium) General Lipoplex-mediated Transfection Mechanism of Action Products > Altogen Biosystems 848 Rainbow Blvd #823 Las Vegas NV 89107 USA Telephone 702 349 6103 Fax 702 989-0841 email [email protected] Leading Developer and Manufacturer of In Vivo and DNA Transfection Kits, Transfection Reagents and Electroporation Delivery Products H9c2 Transfection Reagent (Embryonic Myocardium) H9c2 Transfection Kit Product Details Products > • Two component formulation enhances lipid mediated transfection efficiency • Optimized easy-to-use transfection protocol provided for transfection of siRNA, DNA, mRNA, and microRNA • Kit includes Transfection Enhancer reagent and recommended transfection protocol • High transfection efficacy in the presence of serum • Expand your RNAi application with a reagent optimized for delivery of both siRNA and plasmid • Reproducible transfection results • Works well for standard reverse transfection and high-throughput applications Developed and manufactured by Altogen Biosystems (www.Altogen.com) Altogen Biosystems 848 Rainbow Blvd #823 Las Vegas NV 89107 USA Telephone 702 349 6103 Fax 702 989-0841 email [email protected] Leading Developer and Manufacturer of In Vivo and DNA Transfection Kits, Transfection Reagents and Electroporation Delivery Products Products > H9c2 Transfection Reagent (Embryonic Myocardium) Data Figure 1. GAPD mRNA levels were quantified using real-time RT-PCR in the H9c2 cells transfected with siRNAs targeting GAPD or non-silencing siRNA. Forty-eight hours post-transfection, the cells were harvested and analyzed by real-time RT-PCR for GAPD mRNA expression levels. Data were normalized against the 18S rRNA signal. Control samples were either mock-transfected or untreated. Values are normalized to untreated sample. Data are means ± SD (n=5). Leading Developer and Manufacturer of In Vivo and DNA Transfection Kits, Transfection Reagents and Electroporation Delivery Products Products > H9c2 Transfection Reagent (Embryonic Myocardium) Data Figure 2. Protein expression of GAPDH in H9c2 cells. DNA plasmid expressing GAPDH or siRNA targeting GAPDH were transfected into H9c2 cells following Altogen Biosystems transfection protocol. At 72 hours posttransfection the cells were analyzed by Western Blot for protein expression levels (normalized by total protein, 10 µg of total protein loaded per each well). Untreated cells used as a negative control. Leading Developer and Manufacturer of In Vivo and DNA Transfection Kits, Transfection Reagents and Electroporation Delivery Products H9c2 Transfection Reagent (Embryonic Myocardium) H9c2 Transfection Kit Benefits Products > • Pre-optimized transfection protocol for H9c2 cell line • Compatible with DNA, small RNA (siRNA, shRNA, miRNA), mRNA, and small protein complexing • Free of serum and protein of animal origin • Compatible with standard and reverse transfection methods (both protocols provided in the kit manual) • Easy to use H9c2 transfection protocol ensures great performance with expedited experimental timeline • Equally efficient for single or multiple transfections • Can be used for transient transfection and development of stable H9c2 cell lines • Bio-degradable after endocytosis • Used for preclinical research worldwide Altogen Biosystems 848 Rainbow Blvd #823 Las Vegas NV 89107 USA Telephone 702 349 6103 Fax 702 989-0841 email [email protected]