* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download A.2 Test conditions for lighting equipments
Power inverter wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Electrical ballast wikipedia , lookup
Current source wikipedia , lookup
Three-phase electric power wikipedia , lookup
History of electric power transmission wikipedia , lookup
Electromagnetic compatibility wikipedia , lookup
Electrical substation wikipedia , lookup
Power electronics wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Power MOSFET wikipedia , lookup
Schmitt trigger wikipedia , lookup
Opto-isolator wikipedia , lookup
Distribution management system wikipedia , lookup
Portable appliance testing wikipedia , lookup
Buck converter wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Surge protector wikipedia , lookup
Voltage regulator wikipedia , lookup
Alternating current wikipedia , lookup
Stray voltage wikipedia , lookup
Part 3 LimitsSection 3 : Limition of voltage fluctuations and flicker In low-voltage supply systems for equipment with rated current <16A Group 7A 50262339 Wong Yuk Tung 50247510 Ching Chun 50204951 Eddie Objectives It specifies limits of voltage changes which may be produced by an equipment tested under specified conditions and gives guidance on methods of assessment. Objectives It is applicable to electrical and electronic equipment having an input current up to and including 16A per phase and intended to be connected to public low-voltage distribution system of between 220V and 250V at 50Hz line to neutral. Test Circuit Voltage Fluctuations and Flicker Voltage Fluctuation A series of voltage changes or a continuous variation of the r.m.s. voltage Flicker Impression of unsteadiness of visual sensation induced by a light stimulus whose luminance or spectral distribution fluctuates with time. Assessment of voltage fluctuations and flicker 1. Assessment of a relative voltage change, “d” 2. Assessment of the short-term flicker value,Pst 3. Assessment of long-term flicker value,Ptt 1. Assessment of a relative voltage change Voltage change waveform at the terminals of the EUT difference ΔU of any 2 successive values of the phase-to-neutral voltages U(t1) and U(t2) ΔU = U(t1) - U(t2) 2. Assessment of the short-term flicker value, Pst The flicker severity evaluated over a short period (in minutes); Pst=1 is the conventional threshold of irritability (amendment 1to IEC 868) Assessment method for Pst Types of voltage fluctuation All voltage fluctuations (on-line evaluation) All voltage fluctuations where U(t) is defincd Volatge change waveform according to fig. A to C with an occurrence rate less than 1 per second Method of evaluating Pst Direct measurement Simulation Direct measurement Analyist method Simulation Direct measurement Rectangular voltage changes Use of the Pst=1 at equal intervals curve 2.1 Flickermeter All types of voltage fluctuations may be assessed by direct measurement using flickermeter 2.2 Simulation method When the relative voltage change waveform d(t) is known, Pst can be evaluated using a computer simulation. 2.3 Analytical method Shape factors F for double-step and ramp-voltage characteristics 2.3 Analytical method Shape factors F for rectangular and triangular voltage characteristics 2.3 Analytical method Shape factors F for motor-start voltage characteristics having various front times. 2.3 Analytical method The value of Pst obtained using this method is expect to be within +/- 10% of the result which would be obtained by direct measurement (reference method). This method is not recommended if the time duration between the end of one voltage change and the start of the next is less than 1s. 2.4 Use of Pst = 1 curve For rectangular voltage changes of the same amplitude “d” separated by equal time intervals, Curve may be used to deduce the amplitude corresponding to Pst=1 for a particular rate of repetition; This amplitude is called dlim. The Pst value corresponding to the voltage change “d” is then given by Pst =d/dlim 2.4 Curve for Pst = 1 3. Assessment of long-term flicker value, Plt The flicker severity evaluated over a long period (a few hours) using successive Pst values. e.g. Lighting equipment Shall be tested with a lamp of the that power for which the equipment is rated 6. Test Condition 6.1 General No need for equipments that are unlikely to produce significant voltage fluctuations or flicker. Test setup: Test supply voltage Reference Impedance Equipment Under Test Flickermeter if necessary Test Circuit 6. Test Condition 6.2 Measurement Accuracy Tolerance current (I): +/-1% relative voltage change (d): +/-8% (w.r.t dmax) total impedance: +/-8% (excluding EUT) 6. Test Condition 6.3 Test Supply Voltage Test supply voltage (o/c volt) shall be the rated voltage of EUT. 230V single-phase / 400V three-phase for equipment stated with voltage range. Tolerance: Voltage: +/-2% of nominal value Frequency: 50Hz +/- 0.5% 6. Test Condition 6.5 Observation Period For all assessments, (flickermeter, simulation, analytical) for Pst, Tp = 10mins for Plt, Tp = 2hrs. Observation period shall include part of the whole operation cycle in which the EUT produces the most unfavorable sequence of voltage changes. 6. Test Condition 6.5 Observation Period Short term flicker measurement Operation repeated continuously, unless otherwise specified. Also include time to restart the equipment Long term flicker measurement Operation not repeated, unless otherwise specified. 6. Test Condition 6.6 General Test Conditions Shall be set to produce most unfavorable result using only those conditions that are mentioned by the manufacturer. For equipment having several controlled circuits Each circuit is considered as single item if intended to be used independently. Group of circuit is considered as single item if intended to used simultaneously. For control system regulating part of a load only, the voltage fluctuation produced by each variable part of the load alone shall be considered. 5. Limits Applicable at supply terminal of EUT. Limits: The value of Pst shall not be greater than 1.0 The value of Plt shall not be greater than 0.65 The relative steady-state voltage change, dc, shall not exceed 3%. The max. relative voltage change, dmax, shall not exceed 4% The value of d(t) during a voltage change shall not exceed 3% for more than 200ms. The limits do not apply to emergency switching or emergency interruptions. Annex A Application of limits and type test conditions for specific equipment A.1 Test conditions for cookers A.2 Test conditions for lighting equipments A.3 Test conditions for washing machine A.4 Test conditions for tumbler dryers A.5 Test conditions for refrigerators A.6 Test conditions for copying machines, laser printers and similar appliances A.7 Test conditions for vacuum cleaners A.8 Test conditions for food mixers A.9 Test conditions for portable tools A.10 Test conditions for hairdryers A.11 Test conditions for consumer electronic products A.12 Test conditions for direct water heaters Annex A Application of limits and type test conditions for specific equipment A.2 Test conditions for lighting equipment Pst and Plt are only evaluated for lighting equipment which is likely produce flicker, for example, disco lighting Annex A Application of limits and type test conditions for specific equipment A.9 Test conditions for portable tools Plt shall not be evaluated. Pst Shall be evaluated only when that tool comes with heating elements. Operate continuously for 10mins or until it switch off automatically. Annex A Application of limits and type test conditions for specific equipment A.11 Test conditions for consumer electronic products For consumer electronics products, only the measurement of dmax is required. END THANKS Q&A