Download Sensitive Detection of Three Forms of Thyroid Hormone in

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Hormone replacement therapy (menopause) wikipedia , lookup

Bioidentical hormone replacement therapy wikipedia , lookup

Signs and symptoms of Graves' disease wikipedia , lookup

Growth hormone therapy wikipedia , lookup

Hypothalamus wikipedia , lookup

Hypothyroidism wikipedia , lookup

Hyperthyroidism wikipedia , lookup

Transcript
Sensitive Detection of Three Forms
of Thyroid Hormone in Human
Serum Using the Agilent 6490 Triple
Quadrupole LC/MS System
Application Note
Clinical Research
Authors
Abstract
Rory Doyle and Kevin McCann
Agilent Technologies, Inc.
Santa Clara, CA USA
A rapid method for the quantification of free and total thyroid hormones in
serum was developed using an Agilent 1290 Infinity LC System coupled to an
Agilent 6490 Triple Quadrupole LC/MS System with Agilent Jet Stream (AJS)
technology. Sample preparation was performed using a simple filtration procedure
for free concentrations and a liquid-liquid extraction for total concentrations.
Excellent linearity was observed from 0.5 to 1,000 pg/mL, with run times of only
6.5 minutes.
Introduction
O
O
H
Thyroxine (3,5,3’,5’-tetraiodothyronine
or T4) is the precursor to the more
active form of thyroid hormone,
triiodothyronine (3,3’,5-triiodothyronine
or T3). Reverse triiodothyronine
(3,3’,5’-triiodothyronine or rT3), is an
inactive form of the thyroid hormone
(Figure 1). Most of the thyroid hormone
circulating in the blood is bound to
transport proteins. Only a very small
fraction of the circulating hormone
is free (unbound) and biologically
active. Thus, measuring very low
concentrations of the three forms of
free thyroid hormones is essential to
understanding their roles in the human
body.
This application note describes
the development of an analytical
method for the sensitive and accurate
determination of free and total thyroid
hormones in serum using a 1290
Infinity LC System coupled to a 6490
Triple Quadrupole LC/MS with AJS
technology in positive ionization mode.
Using tandem mass spectrometry
(MS/MS) and multiple reaction
monitoring (MRM), the method is linear
from 0.5 to 1,000 pg/mL, with lower
limits of quantitation (LLOQ) ranging
from 1 to 5 pg/mL for free, and 0.5 to
2.5 pg/mL for total thyroid hormone
determination.
OH
H
NH 2
I
NH 2
I
I
O
HO
I
HO
I
O
I
I
Thyroxine (T4)
Triiodothyronine (T3)
O
OH
H
NH 2
I
I
O
HO
I
Reverse Triiodothyronine (rT3)
Figure 1. The three forms of thyroid hormone found in human serum.
2
OH
Experimental
Reagents and standards
Table 1. LC and MS instrument conditions.
LC conditions
Analytical column
Stock solutions of T4, T3, rT3, and
their 13C-labeled internal standards
(IsoSciences) were prepared at
10 µg/mL in 50:50 methanol: 30 %
ammonium hydroxide, and stored
at –20 °C. Working solutions were
prepared by diluting stock solutions
with methanol. Calibration standard
solutions ranging from 0.5 to
1,000 pg/mL were prepared by spiking
ultra-low hormones and steroids serum
(Golden West Biologics) with various
amounts of stock solution. A labeled
internal standard mixture was created
at 5 ng/mL in methanol. Standard
reference material (SRM 971) was
purchased from the National Institute
of Standards and Technology (NIST).
Instruments
The method was developed on the
Agilent 1290 Infinity LC System coupled
to an Agilent 6490 Triple Quadrupole
LC/MS system with AJS in positive
ion mode. Table 1 lists the instrument
conditions, and Table 2 shows the
6490 Triple Quadrupole LC/MS/MS
acquisition parameters.
Agilent Poroshell 120 EC-C18, 3.0 mm × 100 mm × 2.7 µm
(p/n: 695975-302)
Column temperature
20 °C
Injection volume
20 µL
Mobile phase
A = 0.1 % acetic acid in water, B = Acetonitrile
Gradient
30 % B 0.0 minutes
50 % B 5.0 minutes
98 % B 5.1 minutes
98 % B 5.4 minutes
30 % B 5.5 minutes
Run time
6.5 minutes
Flow rate
0.3 mL/min
Post time
1.5 minutes
MS conditions
Acquisition mode
Agilent JetStream, positive ionization; MRM
Sheath gas temperature
N2; 225 °C
Sheath gas flow rate
11 L/min
Drying gas temperature
N2; 125 °C
Drying gas flow rate
16 L/min
Nebulizer gas pressure
N2; 55 psi
Nozzle voltage
2,000 V
Capillary voltage
4,000 V
Cell accelerator voltage
2V
Delta EMV
500 V
Quadrupole 1/2 resolution
0.7
Table 2. Retention times and acquisition parameters for the thyroid compounds (*Qualifier ions).
Retention time
(min)
Compound
5.1
T4
777.7
731.7
50
21
5.1
T4*
777.7
604.9
50
39
5.1
T4-13C6
783.7
737.7
50
25
4.2
T3
651.8
478.9
50
39
4.2
T3*
651.8
605.8
50
20
4.2
T3-13C6
657.8
611.8
50
19
4.5
rT3
651.8
507.8
50
19
4.5
rT3*
651.8
605.8
50
20
4.5
rT3-13C6
657.8
611.8
50
19
3
Precursor ion
(m/z)
Product ion
(m/z)
Dwell
(msec)
Collision
energy (V)
Sample preparation
Results and Discussion
For the determination of free thyroid
hormones, calibrators and standard
reference material samples were
prepared using Amicon Centrifuge
YM-30 filter units. 500 µL of serum
was added to an Amicon Centrifuge
YM-30 filter and centrifuged at high
rpm for 2 hours. 300 µL of filtrate was
transfered to a clean microfuge tube
along with 30 µL of internal standard
and vortexed. 300 µL of acetonitrile
was added, vortexed for 1 minute and
centrifuged at high rpm for 10 minutes.
The supernatant was transfered to a
96-well plate.
Method performance
Chromatographic separation of T3
and rT3 is critical due to common
MRM transitions. Figure 2 illustrates
the baseline separation obtained for
the three forms of thyroid hormone
obtained from either free thyroid or
total thyroid analyses.
Linearities of calibration curves were
excellent, with coefficients of variation
(R2) ≥0.990 from 0.5 to 1,000 pg/mL.
The R2 values were slightly higher for
free thyroid determinations, versus total
thyroid (Figure 3).
×10 5
5
1
4
1. T3 (651.8 > 478.9)
2. rT3 (651.8 > 507.8)
3. T4 (777.7 > 731.0)
3
Counts
Total thyroid hormone concentrations
were also determined for each of
these samples using an ethyl acetate
liquid-liquid extraction (LLE). A 200-µL
aliquot of sample was combined
with 20 µL of internal standard and
400 µL of acetonitrile in a tube and
vortexed. 1.2-mL of ethyl acetate
was added to the mixture which was
then vortexed for 60 seconds. The
tube was centrifuged at 13,000 rpm
for 10 minutes, and the organic layer
was transferred to a clean tube and
evaporated. The dried sample was
then reconstituted with 120 µL of
75:25 water:acetonitrile.
2
3
2
1
0
0
1
2
3
Time (min)
4
5
6
Figure 2. Chromatographic separation of the three forms of thyroid hormone extracted from human
serum samples.
4
Relative response
1.8
×10
a
3
2
b
R 2 = 0.993
R = 0.999
Relative response
×10
1.2
0.6
2
1
0
0
0
200
400
600
800
1000
0
200
×10
c
×10
6
R 2 = 0.998
3
2
1
0
800
1000
800
1000
d
4
3
2
1
200
400
600
800
1000
0
200
400
600
Concentration (pg/mL)
e
×10
2
f
R 2 = 0.991
R = 0.999
2
1.2
Relative response
Relative response
1000
R 2 = 0.990
Concentration (pg/mL)
1.8
800
0
0
×10
600
5
4
Relative response
Relative response
5
400
Concentration (pg/mL)
Concentration (pg/mL)
0.6
0
0
200
400
600
800
1
0
1000
0
200
400
600
Concentration (pg/mL)
Concentration (pg/mL)
Figure 3. Calibration curves for free/total T4 (a,b), T3 (c,d), rT3 (e,f).
5
The method was sensitive, with LLOQ
ranging from 1 to 5 pg/mL for free
hormones, and from 0.5 to 2.5 pg/mL
total thyroid determinations (Table 3).
Chromatograms for both free and bound
thyroid hormones illustrate the ability
to quantitate these analytes at very low
concentrations (Figure 4).
for free thyroid hormones and a liquidliquid extraction sample preparation for
total thyroid hormones enables rapid
determination of thyroid hormone levels
down to low pg/mL levels.
A sensitive and specific LC/MS/MS
method has been developed for the
simultaneous analysis of thyroxine
(T4), 3,3’,5-triiodothyronine (T3) and
3,3’,5’-triiodothyronine (rT3) in serum.
A simple filtration sample preparation
×102
2
A
Free T4 (777.7 > 731.7) – 5 pg/mL
×102
B
2
Free T3 (651.8 > 605.8) – 1 pg/mL
5.13
1
Counts
1.5
1.5
Counts
Counts
×102
2
Conclusions
4.25
1
C
Free rT3 (651.8 > 507.8) – 5 pg/mL
1.5
1
4.54
0.5
0.5
3.6
4.4
4.8
Acquisition time (min)
5.2
5.6
3.6
4
4.4
4.8
Acquisition time (min)
5.2
3.6
5.6
×102
D
×102
E
2
2
Total T4 (777.7 > 731.7) – 1 pg/mL
5.18
1.5
Counts
Counts
1.5
2
Total T3 (651.8 > 605.8) – 0.5 pg/mL
Counts
×102
4
0.5
4.26
1
1
0.5
0.5
0.5
4
4.4
4.8
5.2
Acquisition time (min)
5.6
3.6
4
4.4
4.8
Acquisition time (min)
5.2
5.6
4.4
4.8
Acquisition time (min)
5.2
5.6
5.2
5.6
F
Total rT3 (651.8 > 507.8) – 5 pg/mL
1.5
1
3.6
4
4.55
3.6
4
4.4
4.8
Acquisition time (min)
Figure 4. MRM traces for the LLOQ concentrations for free and total thyroid hormones.
Table 3. LLOQ for thyroid hormones in human
serum.
Analyte
Free LLOQ
(pg/mL)
Total LLOQ
(pg/mL)
T4
5
1
T3
1
0.5
rT3
5
2.5
www.agilent.com/chem/QQQ
For Research Use Only. Not for use in Diagnostic
Procedures.
This information is subject to change without notice.
© Agilent Technologies, Inc., 2014
Published in the USA, July 21, 2014