* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Motors and Generators by Ian Wilkinson
Geomagnetic storm wikipedia , lookup
Magnetic monopole wikipedia , lookup
Giant magnetoresistance wikipedia , lookup
Earth's magnetic field wikipedia , lookup
Magnetometer wikipedia , lookup
Magnetotactic bacteria wikipedia , lookup
Skin effect wikipedia , lookup
Electromagnetism wikipedia , lookup
Electromagnetic field wikipedia , lookup
Magnetoreception wikipedia , lookup
Magnetotellurics wikipedia , lookup
Magnetochemistry wikipedia , lookup
Magnetohydrodynamics wikipedia , lookup
Lorentz force wikipedia , lookup
Force between magnets wikipedia , lookup
Electromotive force wikipedia , lookup
Alternating current wikipedia , lookup
History of geomagnetism wikipedia , lookup
Ferromagnetism wikipedia , lookup
Induction heater wikipedia , lookup
Superconducting magnet wikipedia , lookup
Electromagnet wikipedia , lookup
Electric machine wikipedia , lookup
Friction-plate electromagnetic couplings wikipedia , lookup
HSC Physics Module 9.3 Summary 1. Motors use the effect of forces on current-carrying conductors in magnetic fields Identify that the motor effect is due to the force acting on a current-carrying conductor in a magnetic field    Recall that a current-carrying conductor produces a magnetic field around the conductor A current-carrying conductor experiences a force in an external magnetic field due to the interaction of its own magnetic field and the external magnetic field This force is called the motor effect, as it is the force used in the operation of motors Discuss the effect on the magnitude of force on a current-carrying conductor of variations in: • the strength of the magnetic field in which it is located • the magnitude of the current in the conductor • the length of the conductor in the external magnetic field • the angle between the direction of the external magnetic field and the direction of the length of the conductor  The magnitude of the force is given by the following equation:  From this equation, we can see that the magnetic force on a conductor depends on a number of factors: o The strength of the external magnetic field. The force is directly proportional to the magnetic field strength, B, measured in Teslas (T) o The magnitude of the current in the conductor. The force is directly proportional to the current, I, measured in amperes (A) o The length of the conductor in the external magnetic field. The force is directly proportional to the length, l, measured in metres (m) o The angle between the direction of the external magnetic field and the direction of the length of the conductor. As it is only the component of the conductor perpendicular to the external magnetic field that experiences a force, the force is proportional to the sine of the angle, hence the term sinΘ  To work out the direction of the force, there are two possible methods: the right-hand palm rule, or the general right-hand rule o For the right-hand palm rule, point your thumb in the direction of the component of conventional current perpendicular to the external magnetic field, and stretch your fingers in the direction of the magnetic field. Your palm represents the direction of the force. o For the general right-hand rule, point your fingers in the direction of the component of conventional current perpendicular to the field, and curl your fingers in the direction of the magnetic field. Your thumb will point in the direction of the force Solve problems and analyse information about the force on current-carrying conductors in magnetic fields using:     See above for a detailed explanation of the force on a current-carrying conductor in a magnetic field Remember to always include directions and units in questions requiring calculations Remember to use the correct angle between the conductor and the field Remember to use the correct directions for current and the magnetic field o Current flows from positive to negative (i.e. the opposite direction to the movement of electrons o A magnetic field points from north to south (i.e. the direction a small north pole would move) Describe qualitatively and quantitatively the force between long parallel currentcarrying conductors:       If two parallel current-carrying conductors are separated by a finite distance, a force will exist between the two conductors due to the interaction of their magnetic fields o The direction of the magnetic fields of each conductor can be determined by using the right-hand grip rule => point your thumb in the direction of conventional current, and curl your fingers into a fist. The direction of your fingers indicates the direction of the magnetic field The diagram below shows two parallel conductors, both with a current in the same direction Consider the effect of wire 1 on wire 2. The magnetic field due to wire 1 would be into the page at wire 2, thus by using the right-hand palm rule, wire 2 experiences a force towards wire 1. The attractive force also occurs for wire 1. Conversely, as the diagram below shows, if the currents are in opposite directions, wire 2 would experience a force away from wire 1, and wire 1 would experience a force away from wire 2, as given by the right-hand palm rule In summary: o If the currents are in the same direction, the force is attractive o If the currents are in opposite directions, the force is repulsive The magnitude of the force is given by the following equation:   Where o F = Force between the two conductors [N] o l = Common length of the parallel conductors [m] o I1 = Current through wire 1 [A] o I2 = Current through wire 2 [A] o d = distance of separation between conductors [m] o k = constant = 2x10-7NA-2 Therefore the force between two parallel current-carrying conductors is directly proportional to the magnitudes of the currents in each wire and the common length of the wires, and inversely proportional to the distance of separation, with the constant of proportionality k. Solve problems using:    Remember the above formula gives the force per unit length between two parallel currentcarrying conductors, so you must multiply by length to get the total force =>see above for detailed qualitative and quantitative analysis Remember to always include directions and units Remember to use the correct direction for current Define torque as the turning moment of a force using   Torque is the turning moment of a force, which can be considered the rotational effect of a force It is easier to rotate an object if the force is applied at a greater distance from the pivot axis, and the force is directed perpendicularly to the line joining the pivot axis to the point of force application o For example, it’s easier to loosen a nut with a spanner than by directly applying a force, as the spanner allows the force to be applied at further distance away from the pivot  Thus torque is quantified by the following relationship:  Torque is calculated using the component of force perpendicular to the rotating arm, so the following relationship should also be considered:   Remember to always state the direction of torque and include units NOTE: Torque is measured in Newton metres [Nm] =>this is NOT equivalent to Joules, as calculations, as torque is a vector whilst energy is a scalar quantity Describe the forces experienced by a current-carrying loop in a magnetic field and describe the net result of the forces  Consider a current-carrying rectangular loop of wire in a magnetic field, shown below          The sides of the loop perpendicular to the field will experience a force due to the magnetic field equal to F=ilB, whilst the sides of the loop parallel to the field will initially experience no force As the loop is fixed to a pivot, the force will cause a torque to be applied to the loop, thus it will begin to rotate in the directions given above The forces on the loop remains constant throughout rotation as the conductors are always perpendicular to the field, but the torque does not, as illustrated in the diagrams below At position 1, the coil is perpendicular to the magnetic field, side WX experiences an upwards force and side YZ experiences a downwards force, as given by the right-hand palm rule. The force causes a maximum torque to be applied to the loop, so the loop begins to rotate. At position 2, the direction of force remains upwards whilst the plane of the coil has changed, so the torque on the coil has decreased as the component of force perpendicular to the rotating arm decreased for both sides WX and YZ At position 3, the coil reaches is perpendicular to the magnetic field, so the component of force perpendicular to the rotating arm is zero, so no torque is applied to the coil, even though sides WX and YZ still experience a force. The coil continues to rotate however, under its own momentum. At position 4, the direction of the current has changed due to the split-ring commutator (see the DC motor section below), thus the forces acting on each side have reversed, and the coil continues to rotate in the same direction. If the current had not changed direction however, the torque would be applied in the opposite direction to rotation, so the coil’s rotation would slow, and eventually reverse direction. The coil would then continue to oscillate At position 5, the coil has completed half a rotation, and the pattern above will repeat If torque is plotted against time, the graph produced would be the absolute value of a cosine curve due to the commutator   NOTE: Whilst sides XY and ZW do not initially experience a force as they are parallel to the field, as the coils rotates their position changes, so they do experience a force. But as the force is not in the direction of rotation, there is no effect on the overall rotation of the moment. NOTE: If the coil had originally was initially perpendicular to the field, it would not rotate as no torque would be applied to the coil Solve problems and analyse information about simple motors using:  Consider the coil shown below  Recall the equation for the force on a current-carrying conductor:  Motors can have many wires wound around at once, so the force is given by:  As the conductor is always perpendicular to the field, sinΘ=1  The magnitude of the torque on each side of the coil is given by  As there are two sides experiencing a force, the torque is given by  Since lxw=A, the area of the coil, the total torque acting on the coil can be expressed as  Where: o τ = Torque on the coil [Nm] o n = Number of coils o B = Magnetic field strength [T] o I = Current through coil [A] o A = Area of coil [m2] o Θ = Angle between the plane of the coil and the magnetic field From the above relationship, it can be seen that there are several ways to increase the rotation speed of a motor by increasing the net torque o Increasing the force on each side of the coil. This can be done by…    Increasing the current in the coil (or increasing the voltage of the external circuit)  Producing a stronger external magnetic field  Using a soft iron core as part of the armature, in the centre of the loop o Increasing the area of the coil, either by increasing width, length, or both o Using more than one coil mounted on the armature o Increasing the number of coils wound onto the armature (with extra split-ring commutators as necessary) to maintain maximum torque o Having stators with curved magnetic poles so torque is at a maximum for the longest possible duration, as well as for smoother operation NOTE: When asked to analyse motors, make sure to mention F=BIlsinΘ and then discuss torque => do not base a discussion around the formula above Describe the main features of a DC electric motor and the role of each feature   An electric motor is a device that transforms electrical potential energy into rotational kinetic energy by passing a current through a coil in a magnetic field. The DC electric motor can be simplified into several key components: o A source of emf and an external circuit with resistors if necessary o The stator, which is all the stationary components of the motor, namely the magnets o The rotor, which consists of a coil wounded on an armature that is free to rotate on an axle o A split-ring commutators and brushes, which change the direction of the current as necessary Part Source of emf Magnets (stator) Description Consists of a source of emf, such as a battery or a power supply. The supplied current flows in one direction (DC), and is often connected to external variable resistors to reduce the chances of excess current flowing, which would burn out the motor. Can either be permanent Role Provides a source current to flow in the external circuit, which allows for a force to be produced inside the coils, hence a torque. The electric potential energy supplied by the emf is converted to kinetic energy in the motor Provide the magnetic field Armature and axle (rotor) Coils (rotor) Split-ring commutators and brushes magnets or electromagnets (see below for greater detail). The poles of the magnet are curved to fit around the armature, and are fixed to the body of the motor. The armature consists of a cylinder of laminated iron mounted on an axle that is free to rotate. Consist of many loops of conductive wire wound onto the armature. The ends of the wires are connected to the bars of the armature. required for a force to be applied to the coils, thus causing the motor effect. Curved poles allows for maximum torque on the rotating coil. The armature strengthens the magnetic field, and provides a base for the wire coils. The axle allows the rotor to rotate. Create rotational kinetic energy from the torque supplied by the motor effect. Having many loops of wire increases the force on each side of the coils, thus increasing torque. The commutator consists of a Causes the current to reverse split metal ring that is in direction every half-rotation, contact with graphite brushes. which allows the rotor to Each part of the split metal rotate in one direction only. If ring is connected to either end current flowed in one of the coil, so the current direction only, the rotor would through the rotor reverses oscillate rather than rotate direction every time torque falls to zero. Graphite is used in the brushes as it conducts electricity and acts as a lubricant. See the diagram of the commutator below. Identify that the required magnetic fields in DC motors can be produced either by current-carrying coils or permanent magnets     The required magnetic fields in DC motors can be produced by either permanent magnets or current-carrying coils Permanent magnets are used in smaller motors. The poles of the magnet curved to maximise torque, and are fixed to the body of the motor Electromagnets, which are used in large DC motors, can be created using a soft iron shape that has coils of wire around it. The current that flows through the armature coil can be used in the electromagnet coils. The iron core strengthens the magnetic field. Below is one possible arrangement for an electromagnet in a DC motor. Identify data sources, gather and process information to qualitatively describe the application of the motor effect in: • the galvanometer • the loudspeaker          GALVANOMETER A galvanometer is a device used to measure the magnitude and direction of small DC currents passing through a particular point. A schematic diagram of a galvanometer is shown below The coil consists of many loops of wire wrapped around an iron core, and is connected in series with the rest of the circuit so that the current in the circuit flows through the wire When the current flows, the coil experiences a force due to the presence of the external magnetic field (the motor effect). This force exerts a torque on the coil, causing it to rotate around the pivot. A spring provides resistance to the torque, and the needle comes to rest when the torque on the coil equals the torque from the spring The iron core of the coil increases the magnitude of the force, which allows for more precise readings The magnets are curved around the coil and iron core. This produces a radial magnetic field, which ensures that the field is always perpendicular to the flow of current along the sides of the coil. Thus the coils experience a force given by F=nBIl, and a torque of τ=nBIA. Applied torque is then in proportion to current, which allows the scale to be linear. LOUDSPEAKER Loudspeakers are devices that transform electrical energy into sound energy. A loudspeaker consists of a circular magnet that has one pole on the outside and the other on the inside, as show below.     An amplifier connected to the coil produces an alternating current that represents the sound signal to be produced When the current passes through the coil, the coil experiences a force due to the magnetic field (the motor effect), which causes it to vibrate back and forth depending on the direction of the current The vibrating coil causes the cardboard cone to vibrate, which produces the sound waves we hear The frequency of the input signal from the amplifier affects the pitch of the sound produced, and the amplitude of the signal affects the volume of sound Perform a first-hand investigation to demonstrate the motor effect         METHOD Two strong bar magnets were clamped horizontally about 1cm apart with opposite poles facing each other. A wire was suspended between the two magnets so that the lower end was free to move. The wire was connected to a DC voltage supply and a light. The current was switched on briefly, and any movement was noted. The supplied voltage was incrementally increased, and any further movements were noted. SAFETY: Connecting a wire to the DC supply can cause it to burn out, which can damage equipment => ensure that there is significant resistance in the circuit by connecting a light bulb in series to the circuit RESULTS The wire moved perpendicularly to the magnetic field when the current was turned on When the supplied voltage was increased, the wire moved further ACCURACY/RELIABILITY/VALIDITY Accuracy is largely irrelevant, as no quantitative measurements were taken The experiment was repeated several times for each supplied voltage, and similar observations were noted, thus it was reliable A zero reading was taken, thus the movement can be attributed to the current in the wire All other possible variables were controlled (e.g. strength of magnets, wire used), so the experiment was largely valid 2. The relative motion between a conductor and magnetic field is used to generate an electrical voltage Outline Michael Faraday’s discovery of the generation of an electric current by a moving magnet     One of Michael Faraday’s numerous discoveries was electromagnetic induction, which is the generation of an electric current by a changing magnetic field Faraday showed that when he moved a magnet near a wire coil, a current temporarily flowed within the coil, which was measured by deflections on a galvanometer Faraday noticed that this current was only induced whilst the magnet was moving, but no current was induced when the magnet was stationary He also demonstrated that moving a north pole out of a coil produced a current in the opposite direction to moving a north pole into a coil at the same speed. In addition, moving a south pole into a coil produced a current in the same direction as moving a north pole out of a coil at the same speed.  Faraday also observed that the magnitude of the induced current depended on the speed at which the magnet was moving towards or away from the coil. The faster the magnet was moving, the greater the induced current  Faraday’s discovery of electromagnetic induction was significant as it led to a new understanding in electromagnetism, and led to the development of generators and transformers, which are essential in modern electrical distribution systems Define magnetic field strength B as magnetic flux density  Below is a magnetic field diagram for a bar magnet  The field lines on the diagram represent magnetic flux, which is a measure of the number of magnetic field passing through a given area => the more lines there are in a given area, the greater the magnetic flux passing through that area Recall that the magnetic field strength is indicated by the spacing of the flux lines => the greater the density of flux lines (i.e. the closer the spacing of flux lines), the stronger the magnetic field We can thus consider a magnetic field strength (B) in terms of magnetic flux density, which is the number of flux lines passing through a unit area   Describe the concept of magnetic flux in terms of magnetic flux density and surface area      As stated above, magnetic flux, ΦB, is a measure of the number of magnetic field lines passing through a given surface area, A, and the field strength, B, is a measure of the density of magnetic flux If the particular area is perpendicular to the field lines, then Where: o ΦB = Magnetic flux [Weber, Wb] o B = Magnetic flux density (or magnetic field strength) [Tesla, T] o A = Area [m2] The above relationship shows that magnetic flux is the number of field lines passing through a perpendicular surface area for a given magnetic flux density If the surface area and magnetic field are not perpendicular, then the magnetic flux equals the component of the magnetic flux density that is perpendicular to the area A. Thus a maximum flux through an area occurs when flux and area are perpendicular Describe generated potential difference as the rate of change of magnetic flux through a circuit      Faraday noted in his experiments on electromagnetic induction that a magnet had to be moving to induce a current in a coil. Further experiments, such as winding two coils onto an iron ring and inducing current in the second circuit, showed that the magnetic field through a coil has to be changing in order for a current to be induced. We can consider the changing magnetic field as the rate of change of magnetic flux through the circuit Faraday also noted that the faster the magnetic flux was changing, the greater the induced current This led to the development of Faraday’s Law of Induction, which states that the induced emf in a circuit is equal in magnitude to the rate of change in magnetic flux. That is, The negative sign indicates the direction of induced emf by Lenz’s Law, which is explained below. The n represents the number of turns of wire in the coil.   Since ΦB=B⊥A, a change in flux can be caused by a change in the magnetic field strength, B, or in the area of the coil that is perpendicular to the magnetic field, or both The generated potential difference can be increased by: o Decreasing the distance between the conductor and the magnetic field, as the flux lines are closer together nearer the magnet o Increasing the strength of the magnet, as there are more flux lines in the same space in a stronger magnetic field than in a weaker field o Increasing the speed of the relative motion between the conductor and the magnetic field, as the conductor cuts more flux lines per unit time o Increasing the angle between the direction of motion of the conductor and the direction of the magnetic field from near zero towards 90 degrees, as the conductor cuts the maximum number of flux lines per second when its motion is perpendicular to the field o Increasing the number of turns in the coil, as the number of coils experiencing a changing flux increases Account for Lenz’s Law in terms of conservation of energy and relate it to the production of back emf in motors        Lenz’s law states that an induced emf in a closed conducting loop will appear in such a direction that it opposes the change that it produced This is a consequence of the Principle of the Conservation of Energy, which states that energy cannot be created nor destroyed, only transformed. Lenz’s law appears in Faraday’s Law as the negative sign Consider the diagram below By Lenz’s Law, the current induced in the coil produces a north pole towards the north pole of the magnet, thus opposing the change in flux, and repelling the magnet away from the coil If Lenz’s Law were not true, and a south pole was induced instead, the magnet would be attracted towards the coil. This would lead to an even greater change in flux, so the induced current would continue to increase, and eventually create infinite ‘free energy’ without input work. This violates the Law of Conservation of Energy, and thus would not occur. Another method to validate Lenz’s Law is to consider the energy before and after an emf is induced in the coil. The magnet is moving towards the coil with an initial velocity v, and its         overall energy is equal to its kinetic energy. As it nears the coil, an emf is induced in the coil, which is a form of electromagnetic energy, so the total energy of the system equals the EM energy and the magnet’s kinetic energy. By the conservation of energy, energy before has to equal energy after, thus the magnet’s kinetic energy has decreased, so the induced current must have opposed its motion. To work out the direction of induced currents, simply create a magnetic field such that it ‘repels’ the change in the magnetic field, and the direction of the current necessary to produce this field is the induced current. For example, consider the coil below that is moving out of a magnetic field. The induced current will oppose the decrease of flux within the coil, so the induced current will produce a magnetic field that is into page within the coil. Thus a clockwise current is induced. More examples of applying Lenz’s Law are shown below BACK EMF IN ELECTRIC MOTORS Electric motors use an input voltage to produce a current in a coil to make the coil rotate in an external magnetic field. As the coil is rotating in a magnetic field, the flux through the coil is changing over time, thus an emf is induced => this emf is called back emf. Back emf opposes the supply emf, otherwise the current would continue increasing, and the motor would go faster forever. The net voltage across the coil equals supply emf minus the back emf The magnitude of back emf is proportional to the rotation speed of the rotor => the faster the rotor is spinning, the greater the change in flux, thus the greater the back emf. When a motor is turned on, the rotation speed of the armature increases, thus the back emf increases. If there is no load on the motor, the back emf will increase until most of the supply emf has been cancelled, so only a small current continues to flow. This residual     current is required to overcome any internal friction and resistive heating, thus the motor operates reaches a constant speed If a load is attached to the motor, the coil rotates at a slower speed due to the additional resistive torque, thus back emf is reduced. This means that the applied potential difference is greater, and a larger current flows through the coils. If a motor is overloaded, the armature will rotate too slowly and will not produce sufficient back emf. This would cause the current to be too high, and the motor would burn out due to resistive heating Motors are usually protected from initially high currents produced when they are switched on by variable series resistors, which switch out of the circuit at higher rotation speeds because the back emf results in a lower current in the coil. Below is a graph of current against time for a DC motor, with a load applied at point C Explain that, in electric motors, back emf opposes the supply emf    As explained above, a back emf is induced in a motor due to the changing magnetic flux through the motor’s coil as the coil rotates If back emf was in the same direction as supply emf, the current would continue increasing and the motor would rotate even faster. Thus the motor would create infinite energy, which would violate the Law of Conservation of Energy. Therefore, by Lenz’s Law, the back emf opposes the supply emf, as it opposes the change in flux through the circuit Explain the production of eddy currents in terms of Lenz’s Law      Recall that the electrons in a conductor are mostly free to move When a conductor experiences a changing magnetic flux, small loops of current called eddy currents are induced within the conductor, which produce their own magnetic fields The direction of eddy currents can be determined by Lenz’s law, i.e. the currents flow in a direction that produces a magnetic field to oppose the change in magnetic flux Eddy currents can be induced from the following changes in flux: o A magnetic field acts on part of a metal object, and there is relative movement between the magnetic field and the object o A conductor is moving in an external magnetic field o A metal object is subjected to a changing magnetic field Consider the sheet of metal moving out of a magnetic field, as shown below:        On the left edge of the magnetic field, charged particles in the metal experience a force because they are moving relative to the magnetic field (remember to consider the forces acting on positive charges, no electrons) To the right of the edge of the magnetic field, charged particles experience no force because there is no relative motion to a magnetic field The accumulation of positive charges at the top of the sheet causes the charges to flow downwards in the metal that is outside the field, which causes an eddy current to be induced By using the right-hand grip rule, we can see that the eddy current produces a magnetic field into the page to oppose the decreasing magnetic flux. The induced magnetic field is attracted to the external magnetic field, thus the sheet of metal experiences a force that opposes its motion Consider the north pole of a magnet moving over and close to the face of an aluminium plate By Lenz’s Law, the circulation of an eddy current ahead of the moving magnet will produce a north pole that will repel the moving magnet. Similarly, an induced eddy current behind the moving magnet will produce a south pole that will attract the moving magnet. Together, these two poles oppose the motion of the magnet over the aluminium plate Gather, analyse and present information to explain how induction is used in cooktops in electric ranges  An induction cooktop consists of a coil below a ceramic surface, as shown below  The coil is connected to a high frequency AC supply, so the coil produces a rapidly changing magnetic field. The rapidly changing magnetic flux through the ceramic surface induces eddy currents in metallic pans, which heats the pan due to resistive heating The heating is maximised if the pan is made of ferromagnetic metal of high resistance, as this increases the power loss due to resistive heating. Induction cooktops will not work with Pyrex glass or ceramic cookers, as these materials are insulators, so no eddy currents will be induced in these cookers. The cooktop surface is made of insulating ceramic material, so no eddy currents are induced in the surface, and the surface remains relatively cool Induction cooktops are much more efficient than gas stove tops, as the heat is generated in the pan itself. Induction cooktops also heat faster than gas stove tops, and the heat is distributed much more evenly     Gather secondary information to identify how eddy currents have been utilised in electromagnetic braking  Consider a rotating metal disk that has part of it influenced by an external magnetic field, as shown below:      As the disk is rotating, the flux changes for a point entering and exiting the magnetic field. This causes eddy currents to be induced in the disk that oppose the change in flux, thus causing the disk to smoothly slow down. Electromagnetic braking is also used in many free-fall amusement rides. A copper plate attached to the ride capsule passes between strong electromagnets near the bottom of the ride, which causes eddy currents to be induced in the copper plate that produce magnetic fields to oppose the motion of the ride. Electromagnetic braking is used in trams and trains. An electromagnetic is switched on so that it an external magnetic field affects part of a metal wheel or the steel rail below the vehicle. If applied to the rail, the magnetic field induces eddy currents to produce a like pole in front of the magnet, and an opposite pole behind the magnet, which oppose the forward motion of the train. The advantage of electromagnetic braking is that the strength of induced eddy currents is proportional to the speed of the vehicle, so the braking force is reduced as the vehicle slows, resulting in smooth braking The disadvantage of electromagnetic braking is that the loss in kinetic energy is transformed to heat energy produced by the eddy currents, which can cause damage to equipment if the heat is no dissipated properly Perform and investigation to model the generation of an electric current by moving a magnet in a coil or a coil near a magnet           METHOD A 500 turn solenoid was attached to a microammeter. The north pole of a bar magnet was rapidly moved in and out of the coil, and any readings on the microammeter were noted. The south pole of the magnet was then rapidly moved in and out, and any further observations were recorded. The magnet was then held stationary, and the coil was moved into the magnet. Any observations were noted. No specific safety applies to this experiment apart from basic laboratory safety RESULTS When the magnet moved in and out of the coil, a current was registered on the ammeter. The current was in opposite directions for moving into the coil and moving out of the coil, and also for moving a north pole into the coil and moving a south pole in. Moving the coil near the magnet produced similar readings to moving the magnet into the coil No current was induced in the coil when the magnet was stationary ACCURACY/RELIABILITY/VALIDITY Only observations were recorded, so accuracy is not a consideration The experiment was repeated several times and produced similar, expected results, thus the investigation was reliable A control reading was taken, which was holding the magnet stationary in the coil All other variables (e.g. number of turns in solenoid, material of wire) were controlled, thus the experiment was valid. Plan, choose equipment or resources, and perform a first-hand investigation to predict and verify the effect on a generated electric current when: • the distance between the coil and magnet is varied • the strength of the magnet is varied • the relative motion between the coil and the magnet is varied            METHOD A 500 turn solenoid was attached to a microammeter. A bar magnet was then moved in and out of the coil, and the reading on the microammeter was recorded. Using the same magnet, the magnet was moved at varying distances to the coil keeping its oscillation speeds as similar as possible. Keeping the same distance and oscillation speed, the strength of the magnet was varied by using one and two, bar magnets together, ensuring the like poles were together. Keeping the same distance and using one bar magnet, the relative motion between the coil and the magnet was varied The readings on the microammeter were recorded for each tested variable. No specific safety applies to this experiment apart from basic laboratory safety RESULTS Variable Magnitude Current induced (μA) Distance Close 50 000 Far 10 000 Strength of magnet One bar magnets 50 000 Two bars magnets 100 000 Speed of magnet Slow 10 000 Medium 50 000 Fast 100 000 The induced current was stronger when: o The distance between the coil and the magnet was smaller o The strength of the magnet was greater o The speed of the magnet was faster ACCURACY/RELIABILITY/VALIDITY The results obtained were estimates from the fluctuating ammeter, and were a guide to verifying the predicted trends, thus were not accurate or reliable The accuracy of the readings could have been improved by using a multimeter or oscilloscope, which could have shown the maximum current for each experiment The trends corroborated with others in the class and with expected results, thus the trends obtained were reliable For each set of readings, all other variables were kept constant (e.g. number of turns in solenoid, material of solenoid), and a control reading was taken, thus the results were valid 3. Generators are used to provide large scale power production Describe the main components of a generator   A generator is a device that transforms mechanical kinetic energy into electrical energy. The diagrams below show a DC generator and an AC generator FEATURE OF GENERATORS Component Description Stator (magnets) Consist of two curved permanent magnets with opposite polarity, or an electromagnet (coil wound around iron core) in largescale generation Rotor (coils and armature) The coil consists of many turns of wire wound on the armature. The armature is a cylinder of laminated iron mounted on an axle. Split-ring commutator and brushes Used in DC motors. Consists of semi-circular metal contacts mounted on the axle. The graphite brushes provide electrical contact to the splitring. Slip ring commutators and brushes Used in AC motors. Consist of two circular metal contacts on the axle, one to each end of the circuit connected to the rotor coils. The graphite brushes provide electrical contact. Can be provided by driving a turbine with steam Energy source Role Provides the external magnetic field, so a current is induced due to the changing flux through the rotating coil. The radial magnetic maximises current, as the sides of the rotor coil are travelling perpendicular to the magnetic field for longer Provides the internal circuit which allows the production of electricity. Torque is applied to the armature to make the rotor spin. Many turns of wire are present to maximise the total flux change as many areas are present Reverses the current every halfrotation when the change in flux through the coil is zero, thus producing current in one direction only. Graphite is used in the brushes as graphite conducts electricity and is a lubricant Allows and alternating current to be produced, as the direction of the current is reversed every halfrotation of the coil. The slip-rings allow the current to vary as it does in the coil, without tangling the wires Provide the mechanical energy to rotate the coil       OPERATION OF GENERATORS A generator is able to produce electricity by using Faraday’s Law of Induction As the coil is forced to rotate in the magnetic field, the flux through the coil is changing as the plane of the coil is changing. Thus the change in magnetic flux induces a current in the coil. Below are graphs of the emf and flux through an AC generator and a DC generator When the plane of the coil is parallel to the magnetic flux lines, it is cutting the maximum number of flux lines, thus a maximum current is induced When the plane of the coil is perpendicular to the magnetic flux lines, no flux lines are being cut, thus there is no current being induced When the coil passes a minimum change in flux, the plane of the coil is facing the opposite direction to its original direction, thus the current induced is in an opposite direction. In a DC    motor, the split-ring commutator changes the direction of the current supplied to the external circuit at this point, thus current in the external circuit is in one direction only The direction of the current can be determined by Lenz’s Law. The current induced in the coil will produce a magnetic field that opposes the change in flux, so the current can be determined by using the right-hand grip rule. Also, the current induced will oppose the rotation of the coil, thus the direction can also be determined via the right-hand palm rule. If given a graph of magnetic flux through a generator coil against time, the direction of the current can be determine by considering emf as the negative gradient of the flux graph, according to Faraday’s Law and Lenz’s Law A DC generator can produce a more steady current by having the multiple coils set in different directions and connected to multiple commutators. The superposition of the outof-phase currents leads to a more constant current  The rotation speed of AC and DC generators affects both the frequency of the current produced, and the maximum emf induced. When the coil is rotated faster, the rate of change of flux through the coil when it is parallel to the external magnetic field is greater, thus the induced emf is greater.  NOTE: When asked to discuss induced currents in generators, ensure to mention emf, as Faraday’s Law of Induction concerns induced emf, not current LARGE-SCALE AC GENERATORS A typical generator in a power station has an output of 22kV, which would require the use of massive coils. This would place huge forces on bearings if they were required to rotate. Thus in large-scale AC generators, the stator consists of coils mounted on an iron core, and the rotor consists of a DC-supplied electromagnet that spins with a frequency of 50 Hz, as shown below.     An alternating current is produced in the coils due to the changing flux through the plane of each coil Power station generators have three sets of coils mounted at angles of 120° to produce AC with three different voltage signals that are out of phase by 120°, as shown below Compare the structure and function of a generator to an electric motor   The structure of both generators and electric motors are similar. Both possess a stator that provides a magnetic field, and a rotor that carries electrical current The main difference between motors and generators is that a motor converts electrical energy into mechanical energy, whilst a generator converts mechanical energy into electrical energy   In a DC motor, the terminals are connected to a power source, and the axle is connected to a load. But in a DC generator, the terminals are connected to a circuit, and the axle is connected to an energy source An AC induction motor is different from an AC generator as its rotor coils are not connected to an external circuit, and its field is always supplied by electromagnets Describe the differences between AC and DC generators   The main difference between AC and DC generators is how they are connected to the external circuit An AC generator is connected via a slip-ring commutator, which produces an output with current going in both directions  On the other hand, a DC generator is connected via a split-ring commutator, which produces an output with current going in one direction only  Note that the internal circuit produces AC in both cases, but the split-ring commutator changes the direction of output so the external circuit receives an absolute-value graph of current Gather secondary information to discuss advantages/disadvantages of AC and DC generators and relate these to their use    DISADVANTAGES OF DC GENERATORS A DC generator requires a split ring commutator for its function. This inevitably complicates the design of the generator. This results in more expensive construction as well as more cost and effort for maintenance The gap present in the split ring commutator results in sparks being produced during the generation of electricity if metal becomes lodged in the insulation. The gap also wears down the carbon brushes more quickly, so the brushes need to be replaced more often than in AC generators, which use smooth slip rings. The output of DC generators (DC electricity) loses more energy than that of AC generators during transmission (see below) ADVANTAGES OF AC GENERATORS            DC generators can produce a smooth currents by having multiple commutators, and superimposing the out-of-phase peaks Some devices, such as battery rechargers, electromagnets, and cathode ray tubes, rely solely on DC currents for their function. Although AC current can be converted to DC current using electronic devices, it is more convenient and cost-effective to produce DC directly using a DC generator For a given voltage, DC current is generally more powerful than AC, so DC is preferred in heavy-duty tools such as a drill. Under this circumstance, DC generators are advantageous DISAVANTAGES OF AC GENERATORS Refer to the advantages of DC generators The phase of AC generators in different regions must be synchronised for electrical production, which increases the cost of their use The output of AC generators is more dangerous than DC generators, as alternating current is more likely to cause heart fibrillation AC is susceptible to energy losses through electromagnetic radiation or magnetic induction ADVANTAGES OF DC GENERATORS Refer to the disadvantages of DC generators Three-phase AC currents are made possible, which can be used for powering induction motors (see section 5 below) AC voltage is easily increased or decreased using transformers (see transformers below), thus AC generators are preferred for large-scale electrical distribution AC can easily be converted to DC using solid state diodes, thus DC can be easily produced by AC generators Discuss the energy losses that occur as energy is fed through transmission lines from the generator to the consumer      The two main types of energy losses that occur as energy is fed through transmission lines from the generator to the consumer are resistive heating in transmission lines, and eddy currents in transformers. Energy losses in transformers will be discussed in the transformers section. Power stations are usually situated large distances from cities (where most of the consumers are located) for environmental and pollution reasons The large distances lead to power losses in transmission to the consumer due to the resistance of the material used in transmission lines The power loss can be calculated by Joule’s law: where: o P = Power [W] o I = Current [A] o R = Resistance [Ω] Thus to minimise power losses in transmission wires, low currents are supplied, and the resistance of the material needs to be minimal       The current through transmission wires can be achieved using transformers (see section 4), which only operate using AC electricity. Thus AC electricity is used in power distribution networks. According to P=VI, a low current will result in a high voltage for the same power output. This requires high poles or towers and large insulators, which are expensive to build and maintain. Trees must also be kept well clear from high voltage transmission lines to reduce the possibility of a short to earth, which can result in environmental concerns. Power losses can also be reduced by using wires of minimal resistance. The resistance of a conductor of resistivity ρ, area A, and length l is given by Thus transmission lines are typically made of aluminium as it has low resistivity Resistance is also inversely proportional to area, so the thicker the conductor, the lower the heat loss. But thick wires are also heavier, so require larger structures to support them, which are more expensive. This is why aluminium is used in transmission lines as opposed to copper (which has a lower resistivity), as aluminium is a lighter metal than copper, which allows for thicker wires and reduces construction costs. Recent experiments with superconducting material transmitting DC show some promise for reducing energy losses from high voltage transmission lines in the future. DC does not induce eddy currents in support structures, so energy losses would be further minimised Analyse secondary information on the competition between Westinghouse and Edison to supply electricity to cities       In the late 19th century, Edison favoured generating and supplying DC electricity, whilst Westinghouse promoted the use of AC electricity Edison had a vested interest in DC, as electricity was primarily used for household lighting, and he had patents on much of the technology involved The drawback of a DC system was that it had to be distributed at the voltage used in households, as transformers do not work with DC. Transmission therefore required large currents, which limited the distance DC could be transmitted to several kilometres. This required many power stations throughout cities, and was impractical for rural areas. Westinghouse purchased many of the patents for AC motors and generators. AC was economically advantageous due to the smaller power losses and the ability to place largerscale generators further apart. Edison attempted to discredit the use of AC and promote it as unsafe. This included using an AC generator to publicly electrocute animals, including an elephant. He also provided the New York state prison system with AC generators for use on electric chairs, which Edison called being ‘Westinghoused’. The economic advantages of AC power distribution ultimately led to Westinghouse’s system being favoured in large electricity generation projects, notably the hydroelectric plant at Niagara Falls. Due to its many advantages, AC electricity was eventually adopted as the standard worldwide. Gather and analyse information to identify how transmission lines are: • insulated from supporting structures • protected from lightning strikes         INSULATION FROM SUPPORTING STRUCTURES In dry air, sparks can jump a distance of 1cm for every 10kV of potential difference. Therefore a transmission line carrying a 330kV line will spark to a metal tower if it comes within a distance of 33cm, and even larger distances in humid weather. Typically, the wires are held more than a metre from supporting structures by large insulators, one of which is shown below The insulator consists of a series of connected ceramic discs, and at higher voltages, the chains are longer The insulators are designed to shed water and prevent dust from building up, as either moisture or dust can made a conductive path across the surface of the insulator The disc-like shape of the segments increases the distance that a current has pass over the surface of the insulator, and so decreases the risk. PROTECTION FROM LIGHTNING STRIKES Transmission lines and towers are susceptible to lightning strikes, as they are built high above the ground The transmission towers are designed to minimise the risks of lightning strikes by acting as a good conductor to the ground. The towers are well-earthed, with a large surface area of metal buried in the ground, and the towers are widely-spaced to ensure minimal damage to other towers if one is struck The uppermost transmission wires are earth wires, which mean they carry no current. It protects transmission lines from sudden surges in voltage by conducting any current due to lightning strikes to Earth, as lightning is most likely to strike the uppermost wires. Assess the effects of the development of AC generators on society and the environment                The development of AC generators in the 20th century enabled the widespread availability of electricity, which have had a highly significant impact on society and the environment POSITIVE IMPACTS ON SOCIETY The ability to transmit electricity efficiently over long distances has allowed more people in large cities to live further from the city centre AC is cheaper to transmit than DC, so the development of AC generators has allowed for cheaper electrical power distribution, and allowed electrical transmission to rural areas to be practical The use of electricity at home and in industry has reduced manual labour, allowing for greater leisure time Electricity has allowed for worldwide communication and many consumer products considered necessary in modern life, such as refrigerators, medical equipment, and computers NEGATIVE IMPACTS ON SOCIETY Electrical machinery has replaced many jobs, which has increased unemployment in some areas of society Sites of electrical power plants has led to the displacement of many people from their homes, particularly for hydro-electric power plants The proliferation of electronic devices has led to a more sedentary lifestyle, which has inherent medical problems POSTIIVE IMPACTS ON THE ENVIRONMENT AC generators have allowed power plants and industry to move outside cities, which has improved the urban environment and the health of city dwellers The availability of electric power has reduced the need to burn wood or coal in houses, significantly improving air quality in large cities NEGATIVE IMPACTS ON SOCIETY The construction of long-distance power lines often require the destruction of habitat, which has also increased rates of erosion where vegetation has been removed The burning of fossil fuels for electricity production has led to many negative environmental impacts, such as acid rain, thermal pollution of marine ecosystems, release of particulate matter, and release of greenhouse gases Radioactive waste from nuclear power plants poses a threat to the environment if not contained Dams required for hydro-electric power plants have destroyed the habitat of many plants and animals Land has been degraded at mining sites for materials required in electrical generation Plan, choose equipment or resources, and perform a first-hand investigation to demonstrate the production of an alternating current   METHOD A 500-turn solenoid was connected to a galvanometer, and a bar magnet was repeatedly moved in and out of the solenoid. The readings on the galvanometer were observed and recorded. No specific safety applies to this experiment apart from basic laboratory safety         RESULTS The reading on the galvanometer oscillated, reaching both positive and negative values. The maximum current occurred when the magnet was moved quicker in and out of the coil ACCURACY/RELIABILITY/VALIDITY No quantitative data was obtained, so accuracy was not of concern Reliability was improved by repeating the experiment and comparing results to others in the class A control reading was taken with the magnet stationary inside the coil, so the production of an alternating current can be attributed to the moving magnet The galvanometer and solenoid were correctly wired, so the equipment provided valid results All other variables were controlled (e.g. solenoid used, magnet used), thus the experiment was valid Possible problems with the experiment include using a galvanometer that isn’t sensitive enough, loose wire connections, and slow movement of the magnet (the flux change would be too slow for a significant current to be induced) The experiment could have been improved by using an oscilloscope to measure induced current 4. Transformers allow generated voltage to be either increased or decreased before it is used Describe the purpose of transformers in electrical circuits       Transformers are devices that increase or decrease AC voltages in electrical circuits The domestic supply voltage in Australia is 230V single-phase AC, but some devices require lower voltages (such as amplifiers in radios) or higher voltages (such as the cathode ray tubes in CRT televisions) to operate. Thus transformers are placed in the circuit between the AC supply and the component to reduce or increase the supplied voltage. Below is a diagram of a common type of transformer Transformers generally consist of two coils of insulated wire with a different number of turns called primary and secondary coils. These coils can be wound together on the same laminated iron core so maximum magnetic flux from the primary coil passes through the secondary coil The changing current in the primary coil creates a changing magnetic flux, which passes through the secondary coil. The changing flux induces an emf in the secondary coil of the same frequency, but not of the same voltage or current (see below) Transformers only work on AC, as a changing magnetic flux is required to induce a current in the secondary coil. Using DC in the primary coil would produce a constant flux, thus no emf would be induced in the secondary coil. Compare step-up and step-down transformers   A step-up transformer is a transformer that increases voltage, whilst a step-down transformer decreases voltage Below is a table summarising the differences between step-up and step-down transformers. Coil ratios will be discussed in the next section Type Step-up transformer Step-down transformer Structure Consists of two inductively coupled coils wound on a laminated iron core Coil ratios More turns in the secondary coil Fewer turns in the secondary coil Voltage output Current output Role in power distribution Domestic use than the primary coil Higher output voltage than input voltage Lower output current than input current Used at power stations to increase voltage and reduce current for long-distance transmission Used in television sets to increase the voltage to operate the picture tube than the primary coil Lower output voltage than input voltage Higher output current than input current Used at substations and in towns to reduce transmission line voltage for domestic and industrial use Used in computers, radios, and CD players to reduce household electricity to very low voltages for electronic components Identify the relationship between the ratio of the number of turns in the primary and secondary oils and the ratio of primary to secondary voltage  By applying Faraday’s Law of Electromagnetic Induction, the magnitude of the voltage output of the secondary coil is given by  Similarly, the input primary voltage is related to the change in magnetic flux by the same equation  As mentioned above, transformers are designed so that almost all of the magnetic flux produced in the primary coil threads through the secondary coil. Assuming 100% efficiency, the terms ΔΦB/Δt in both of the above equations are equal, thus dividing the second equation by the first equation gives Solve problems and analyse information about transformers using:   Be careful to distinguish between the primary and secondary coil in questions Remember that whilst ratios do not have units, voltage does, so include relevant units in calculations Explain why voltage transformations are related to conservation of energy  The Principle of Conservation of Energy states that energy cannot be created nor destroyed, but only transformed from one form to another     Thus the power output of an ideal transformer equals the power input. In most transformers, some energy is lost due to eddy currents in the iron core, so power output is in fact less than power input Recall that power in electrical circuits can be given by P=VI. If there is no power loss, Pp=Ps, so VpIp=VsVs. Substituting into the transformer equation gives the following: The above expression shows that current and voltage in a transformer are inversely proportional. Thus in a step-up transformer, where voltage is increased, the output current is less than the input current. Also, in a step-down transformer, the output current is greater than the input current, so ideally no power is lost. Real transformers produce heat, however, because the changing magnetic flux produces eddy currents in the iron core. Thus in real transformers, output power is generally less than input power . Gather, analyse and use available evidence to discuss how difficulties of heating caused by eddy currents in transformers may be overcome     The coils of wire in transformers are generally wrapped around a soft iron core to concentrate the magnetic field, allowing a maximum possible inductive coupling between the primary and secondary coil As transformers depend on a changing magnetic field in order to operate, the flux through the iron core rapidly changes, which induces eddy currents in the iron. The eddy currents cause heating in the iron cores due to the high resistance of iron to eddy currents, which causes power to be lost in transformers Excessive heating can also damage or destroy the transformer, so power losses in transformers needs to be reduced. One of the primary ways to reduce heating in transformers is to construct the cores out of laminated iron o Laminated iron consists of thin sheets of iron pressed together, but separated by thin insulating layers o By positioning the cross-section of insulating layers perpendicularly to the direction of magnetic flux, the size of eddy currents can be greatly reduced, as the eddy currents are limited to the thickness of one lamina   Heating can also be reduced by constructing iron cores out of ferrites, which are complex of iron and other metals. These materials are good transmitters of magnetic flux, but poor conductors of electricity, so the magnitude of eddy currents are significantly reduced Once the transformer becomes hot, it must be cooled to prevent overheating, which can be achieved in a variety of ways: o The transformer can be made of black material so that heat produced internally can be efficiently radiated to the environment => most domestic transformer rectifier units are made out of black material o Pad-mounted transformers at ground level have ventilated cases to allow air to remove heat by convection. They may also have an internal fan to assist air circulation and remove heat faster. Explain the role of transformers in electricity sub-stations    Recall that electricity is transmitted at high voltages (up to 500kV) over long distances from the power station to the sub-station to reduce power losses The domestic electricity supply is typically 230V single-phase AC, whilst the industrial electricity supply is usually 415V three-phase AC, thus the voltage needs to be reduced for consumer use The voltage of electricity is progressively reduced at sub-stations, where step-down transformers are used to reduce voltage for the consumer. At each stage, the output voltage is chosen to match the power demand and the distance over which supply is needed Gather and analyse secondary information to discuss the need for transformers in the transfer of electrical energy from a power station to its point of use          Electricity is typically consumed in homes at 230V and in industry at 415V. If there were no transformers to change voltage, electricity would have to be generated and distributed at these same voltages. In order to transmit electricity efficiently over long distances, a low current is required (recall P=I2R), which in turn means that electricity must be transmitted at high voltages of up to 500kV In addition, power stations run more efficiently if electricity is generated at higher voltages, such as 23kV Thus transformers are needed in the transfer of electrical energy from a power station to its point of use, as each stage of transmission runs more efficiently and economically at certain voltages and currents ELECTRICAL POWER DISTRIBUTION Electricity at the generator is typically produced at levels of 23kV A step-up transformer is used to increase the voltage to higher voltages (generally 330kV), which is transmitted to regional substations At regional substations, step-down transformers are used to reduce voltage to 110kV or 66kV for regional distribution Local substations use step-down transformers to reduce voltage to 33kV or 11kV for distribution along local streets Finally, pole transformers reduce voltage to 230V (domestic) or 415V   Power substations usually perform three tasks: o Step down the voltage using transformers o Split the distribution voltage to go in different directions o Enable, using circuit breakers and switches, the disconnection of the substation from the transmission grid or sections of the distribution grid to be switched on and off The diagram below summarising the use of transformers in power transmission Discuss why some electrical appliances in the home that are connected to the mains domestic power supply use a transformer     Australian houses are provided with 230V AC electricity. Whilst many devices are designed to operate efficiently at this voltage, some appliances contain components that operate best at different voltages from the mains supply For example, the component within a microwave oven that produces the microwaves typically requires thousands of volts, whilst the control circuits and control panel on the front only require small voltages. This means that a microwave oven would require both step-up and step-down transformers to supply the power for its components. Another device that requires a step-up transformers is the cathode ray tube in CRT television, which require voltages of up to 25kV Devices that require step-down transformers include electric keyboards, answering machines, the amplifier in radios, and the batteries in cordless telephones and laptop computers. Most electronic circuits are designed to operate at low DC voltages. Discuss the impact of the development of transformers on society       The development of transformers has allowed electrical energy to be efficiently transmitted over great distances. This had had a range of impacts on society: POSITIVE IMPACTS Power stations can be placed far away from urban centres, otherwise many power stations would be required in cities. This reduces pollution, reduces cost and improves the standard of living of people living in cities. Transformers enable power from one power station to be used in many different applications, as the voltage can be changed as required. Without transformers, different industries requiring different voltages would have to build generators to produce those specific voltages, which would have extra cost and cause more urban pollution. Transformers have enabled the construction of many electronic labour-saving and entertainment devices, such as TVs, computers, mobile phones, electronic clocks, and kitchen appliances. See section three on the advantages of generators for more positive impacts NEGATIVE IMPACTS See section three on the disadvantages of generators for negative impacts Perform an investigation to model the structure of a transformer to demonstrate how secondary voltage is produced           METHOD A 300 turn solenoid was placed inside a 5000 turn solenoid of a larger radius. The smaller solenoid was connected to an AC supply, whilst the larger solenoid was connected to both ends of an adjustable spark gap. The AC supply was turned on, and any observations were noted. Draw the apparatus if possible when asked SAFETY The sparks produced can produce X-rays, which are harmful to cells if exposed for too long. Stand at least 3m away from the apparatus whilst the AC supply is turned on to reduce exposure (according to the inverse square law) Ozone is also produced by the spark gap, which can cause respiratory damage if inhaled. Conduct the experiment in a well-ventilated are to minimise this problem RESULTS When the AC supply was turned on, sparks would jump across the gap, which demonstrated the induction of a current in the secondary coil As the primary coil was connected to an AC supply, the flux produced by the coil was rapidly changing, which in turn induced an emf in the secondary coil The voltage produced by the secondary coil can be calculated using the transformer equation ACCURACY/RELIABILITY/VALIDITY No quantitative data was recorded, so accuracy is irrelevant The experiment was repeated, and sparks occurred each time, so the experiment was reliable   A control reading was taken with the AC supply turned off, which produced no sparks Problems with the experimental design include the following: o Not all the flux from the primary coil threaded through the secondary coil, which could have been improved by using a soft iron core o Some of the power from the primary coil was transferred to heat, which reduced the efficiency of the transformer 5. Motors are used in industries and the home usually to convert electrical energy into more useful forms of energy Describe the main features of an AC electric motor          There are two main types of AC electric motors: the universal motor, and the AC induction motor UNIVERSAL MOTOR The universal motor is designed to operate on both single-phase AC and DC, and is the most common type of motor in domestic appliances Below is a schematic diagram of a universal motor The stator consists of coils wound around a laminated iron core, which acts as an electromagnet The rotor consists of several coils wound onto the rotor armature, which are connected in series with the electromagnet coils. The ends of the rotor coils connect to opposite segments of a commutator. The interaction between the current in the rotor coils and the external magnetic field produces the torque that makes the rotor rotate An external variable resistor controls the speed of the universal motor by varying the current through the motor Even though the direction of the current is changing when operating using AC, the rotor will rotate in the same direction because the magnetic field flux of the stator is also changing with the same frequency The diagram shows the various components of a universal motor           AC INDUCTION MOTOR An induction motor operates on the principle of electromagnetic induction, as the changing magnetic field set up in the stator induces a current in the rotor, which produces a torque and causes the rotor to rotate The simplest induction motor is the three-phase induction motor, though single-phase induction motors are available The main components of the three-phase induction motor are the stator and the squirrelcage rotor Below is a diagram of the stator: The stator consists of three pairs of electromagnet coils, each of which is connected to an individual phase of the three-phase supply The out-of-phase AC produces a rotating magnetic field that has constant magnitude, which rotates at the same frequency as the mains supply (i.e. 50Hz) Below is a diagram of the squirrel-cage rotor Around the circumference of the rotor are a number of parallel conducting bars made of either aluminium or copper, hence the name squirrel-cage rotor. These bars are joined at the ends by an end ring that allows current to flow from one bar to another. The rotor is encased in a laminated iron armature to intensify the magnetic field, and the armature is mounted on a shaft that passes out through the end of the motor and is free to rotate The rotating stator field induces a current in the bars of the rotor, which experiences a torque due to the magnetic field. The force is always in the same direction as the movement of the magnetic field, so the rotor ‘chases’ the rotating magnetic field  To work out the direction of the force, remember that a magnetic field moving to the right relative to a stationary conductor has the same effect as a current-carrying conductor moving to the left in a stationary magnetic field  If the bars of the squirrel cage were to rotate at exactly the same rate as the magnetic field, there would be no relative movement between the bars and the magnetic field, thus no induced current and no torque For the rotor to experience a force there must be relative movement or a ‘slip’, which is caused by the retarding torque on the rotor when a load is attached. The difference between the rotational speeds of the coil and the magnetic field is called the ‘slip speed’ When a large load is attached, the slip speed of the rotor is greater, thus the induced current and magnetic torque are increased The induction motor contains no brushes or commutator, which means easier manufacture, no wear, no sparks, no ozone production, and none of the energy loss associated with them Below is a table summarising the different types of motors and their uses     Gather, process and analyse information to identify some of the energy transfers and transformations involving the conversion of electrical energy into more useful forms in the home and industry  Electrical energy is transferred from the power station to the homes and industries through transmission lines and transformers (see the relevant sections above for more details)   Electrical energy is then transformed into more useful forms. Remember that not all transformations are 100% efficient, and other forms of energy may also be produced as waste energy The table below summaries energy transformations in the home and industry Form of energy Home Industry Heat Induction cooktops, home Furnaces heating, hot water system Light Light bulbs Neon lights, laser printing Sound Speakers Chemical Recharging batteries Producing batteries, electroplating Kinetic Blender, fan, drill Industrial motors, transport Perform an investigation to demonstrate the principle of an AC induction motor           METHOD The base of an aluminium drink can was attached to a long piece of fine thread. The thread was attached to a clamp on a retort stand, and was allowed to hang vertically and freely rotate. A bar magnet was then firmly attached to the end of a drill bit, and the drill bit was secured in the drill chuck of a hand drill. The hand dill was rotated so that the magnet would spin in one direction. The bar magnet was then removed, and rotated similarly. Below is a diagram of the apparatus: SAFETY: Make sure that all components are secured properly, as the rotation may cause them to fly off, and cause damage to equipment and potential injury RESULTS The rotating magnet caused the aluminium disc to rotate in the same direction as the magnet. The faster the magnet was rotated, the faster the disc rotated. The closer the magnet was to the disc, the faster the disc rotated. The disc did not rotate when the magnet was removed, which suggests that the disc rotated due to electromagnetic interaction ACCURACY/RELIABILITY/VALIDITY No quantitative data was obtained, so accuracy is irrelevant The experiment was repeated several times with similar observations, and similar results were obtained by other members of the class The rotating drill chuck without the magnet acted as the control, which confirmed that the rotating magnet caused the disc to rotate All variables were controlled, such as the type of disc used and the hand drill used Potential problems with the experiment include: o o o Impurities in the aluminium can may reduce the conductivity of the can, thus it may be difficult to cause the disc to rotate The tangling of the thread may reduce the ability of the disc to rotate The hand drill may not provide the rotation speeds required to cause the disc to rotate
 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
									 
                                             
                                             
                                             
                                             
                                             
                                             
                                             
                                             
                                             
                                             
                                            