* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Transformers
Pulse-width modulation wikipedia , lookup
Spark-gap transmitter wikipedia , lookup
Portable appliance testing wikipedia , lookup
Ground loop (electricity) wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Mercury-arc valve wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Power inverter wikipedia , lookup
Electrical ballast wikipedia , lookup
Ground (electricity) wikipedia , lookup
Power engineering wikipedia , lookup
Current source wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Earthing system wikipedia , lookup
Schmitt trigger wikipedia , lookup
Distribution management system wikipedia , lookup
Power MOSFET wikipedia , lookup
Stepper motor wikipedia , lookup
Single-wire earth return wikipedia , lookup
Power electronics wikipedia , lookup
Electrical substation wikipedia , lookup
Buck converter wikipedia , lookup
History of electric power transmission wikipedia , lookup
Voltage regulator wikipedia , lookup
Opto-isolator wikipedia , lookup
Surge protector wikipedia , lookup
Stray voltage wikipedia , lookup
Three-phase electric power wikipedia , lookup
Resonant inductive coupling wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Voltage optimisation wikipedia , lookup
Alternating current wikipedia , lookup
Transformers Single Phase Transformers Principles of Operation β Single Phase Flux and Voltage 90o out of phase Relationship of induced voltage and flux: Also Eqn 1.148 Fundamental Transformer equation Only accurate if leakage impedance of coil is negligible Primary winding flux divided into leakage flux and mutual flux Ideal Transformer Relationships Exercise 2-1 π1 π1 = β‘π π2 π2 πΌ2 π1 = β‘π πΌ1 π2 π1 π1 = π2 π2 2 β‘ π2 Non-ideal Transformer Equivalent Circuits of a non-ideal Transformer Equivalent Circuits of a non-ideal Transformer π β‘ π‘π’πππ πππ‘ππ > 1 πΈ1 β‘ πππππππ¦ ππππ’πππ π£πππ‘πππ πΈ2 β‘ π ππππππππ¦ ππππ’πππ π£πππ‘πππ π1 β‘ πππππππ¦ π‘πππππππ π£πππ‘πππ π2 β‘ π ππππππππ¦ π‘πππππππ π£πππ‘πππ πΌ1 β‘ πππππππ¦ ππ’πππππ‘ πΌ2 β‘ π ππππππππ¦ ππ’πππππ‘ πΌ0 β‘ ππ β ππππ πππππππ¦ ππ’πππππ‘ π 1 β‘ πππ ππ π‘ππππ ππ π‘βπ πππππππ¦ π€ππππππ π 2 β‘ πππ ππ π‘ππππ ππ π‘βπ π ππππππππ¦ π€ππππππ π1 β‘ πππππππ¦ πππππππ πππππ‘ππππ π2 β‘ π ππππππππ¦ πππππππ πππππ‘ππππ πΌπ , ππ β‘ ππππππ‘ππ§πππ ππ’πππππ‘ πππ πππππ‘ππππ πΌπ , π π β‘ ππ’πππππ‘ πππ πππ ππ π‘ππππ πππππ’ππ‘πππ πππ π‘βπ ππππ πππ π ππ Open-Circuit (or No-Load) Test Here one winding is open-circuited and voltage---usually, rated voltage at rated frequency--is applied to the other winding. Voltage, current, and power at the terminals of this winding are measured. The open circuit voltage of the second winding is also measured, and from this measurement a check on the turns ratio can be obtained. It is usually convenient to apply the test voltage to the winding that has a voltage rating equal to that of the available power source. In step-up voltage transformers, this means that the open-circuit voltage of the second winding will be higher than the applied voltage, sometimes much higher. Care must be exercised in guarding the terminals of this winding to ensure safety for test personnel and to prevent these terminals from getting close to other electrical circuits, instrumentation, grounds, and so forth. In presenting the no-load parameters obtainable from test data, it is assumed that voltage is applied to the primary and the secondary is open-circuited. The no-load power loss is equal to the wattmeter reading in this test; core loss is found by subtracting the ohmic loss in the primary, which is usually small and may be neglected in some cases. Thus, if Po, Io and Vo are the input power, current, and voltage, then the core loss is given by: ππ = ππ β πΌπ 2 π 1 The primary induced voltage is given in phasor form by: π¬π = ππ β 0π β (πΌπ β π π )(π 1 + ππ1 ) where π π β‘ no-load power-factor angle = πππ β1 Other circuit quantities are found from: πΈ1 π π = ππ ππ πΌπ = πΈ1 πΌπ = 2 πΌ0 πΈ1 ππ = πΌπ ππ aβ πΈ2 2 β πΌπ 2 ππ ππ πΌπ < 0. Short-Circuit Test In this test, one winding is short-circuited across its terminals, and a reduced voltage is applied to the other winding. This reduced voltage is of such a magnitude as to cause a specific value of current---usually, rated current--to flow in the short-circuited winding. Again, the choice of the winding to be short-circuited is usually determined by the measuring equipment available for use in the test. However, care must be taken to note which winding is short-circuited, for this determines the reference winding for expressing the impedance components obtained by this test. Let the secondary be short-circuited and the reduced voltage be applied to the primary. With a very low voltage applied to the primary winding, the cord-loss current and magnetizing current become very small, and the equivalent circuit reduces to that of Fig. 2-6. Thus, if Ps, Is, and Vs are the input power, current, and voltage under short circuit, then, referred to the primary, ππ = ππ πΌπ π 1 + π2 π 2 β‘ π π = ππ πΌπ 2 π1 + π2 π2 β‘ ππ = ππ 2 β π π 2 Given R1and a, R2 can be found. It is usually assumed that the leakage reactance is divided equally between the primary and the secondary; that is: π1 = π2 π2 = 1 π 2 π Short Circuit Test: (Impedance or copper-loss test) Open Circuit Test: Core-loss test Usually done on the side of the transformer with the lower rated voltage Transformer Characteristics: Inrush 8 to 12 times rated current, duration about 100 ms Efficiency Regulation kVA Rating Apparent power or kVA is always inscribed on the nameplate As long as the transformer delivers rated or reduced kVA, it will operate with nominal heat If it is cooled, it can safely deliver higher-than-rated kVA A transformer of 1000 kVA supplied with fans can deliver 1333kVA Protective equipment such as circuit breakers and fuses, must be capable of safely withstanding the forces produced by the short-circuit currents. It is customary in industry to rate the short-circuit capacity of equipment in terms of short-circuit MVA. Three-Phase, Two-Winding Transformers Review of Three-Phase Systems P = 3VLβL IL cos ΞΈ Q = 3VLβL IL sin ΞΈ S = 3VLβL IL * Delta-Connected Load Star-Connected Load Electric Circuit Analysis Star-Delta Star-Star Auto Transformers Understanding and analyzing autotransformers is simplified by noting the following: 1. The ampere-turns of each coil are the same whether the transformer is connected as an autotransformer or as a two-winding transformer. That is, (NI)= constant In other words, the magnitude of the current through each coil remains the same, regardless of whether the transformer operates as an autotransformer or as a conventional twowinding transformer. 2. Since the current through each autotransformer winding is the same as in the conventional two-winding transformer, the winding loss remains the same. However, the efficiency of the autotransformer is increased if the output power is increased. 3. Neglecting losses, the complex power (kVA) at the input is equal to the complex power to the output. The kVA transformation capability of the autotransformer is the same as that of the two-winding transformer. An autotransformer, however, delivers higher kVA than the conventional transformer because of the direct electrical connections between the primary and secondary windings. In other words, part of the output kVA is conducted from the primary to the secondary winding. The conducted kVA is referred to as the untransformed kVA. 4. The two-winding conventional transformer has its primary and secondary circuits electrically isolated, while in the autotransformer electrical disturbances in the primary can be easily passed to the secondary through their direct electrical connections. Disadvantages of Autotransformers The disadvantages of autotransformers are as follows: They are not economical for voltage ratios larger than 2. They require primary protective devices of higher capacity. 1. Because of the electrical conductivity of the primary and secondary windings, the lower voltage circuit is liable to be impressed upon by higher voltage. To avoid breakdown in the lower voltage circuit, it becomes necessary to design the low-voltage circuit to withstand higher voltage. 2. The autotransformer has a common terminal between the primary and the secondary windings and when the secondary is shorted, the voltage applied to the primary is much higher than its rated voltage. This results in higher short-circuit currents and thus requires more expensive protective devices. 3. The connections on the primary and secondary sides must necessarily be the same, except when using interconnected starring connections. This introduces complications due to changing primary and secondary phase angles, particularly in the case-by-case of the delta-delta connection. 4. Because of a common neutral in a star-star connected autotransformer, it is not possible to ground the neutral of one side only. Both if its sides must have its neutrals either grounded or isolated. 5. It is more difficult to preserve the electromagnetic balance of the winding when voltage adjustment tappings are provided. It should be known that the provision of adjusting tapping on an autotransformer increases the frame size of the transformer considerably. Parallel Operation of Transformers: Equal impedance Equal turns ratio Equal phase shift between primary and secondary open-circuited voltages Same phase rotation