
REGULATORY GUIDE
... needed to operate electrical equipment and they transmit signals to and from the various devices used to perform safety functions and accident mitigation in a nuclear power plant. Despite their importance, cables typically receive little attention because they are considered passive, long-lived comp ...
... needed to operate electrical equipment and they transmit signals to and from the various devices used to perform safety functions and accident mitigation in a nuclear power plant. Despite their importance, cables typically receive little attention because they are considered passive, long-lived comp ...
DRV632 DirectPath, 2-VRMS Audio Line Driver
... capacitor, typically 1 μF, placed as close as possible to the device VDD lead works best. Placing this decoupling capacitor close to the DRV632 is important for the performance of the amplifier. For filtering lower-frequency noise signals, a 10-μF or greater capacitor placed near the audio power amp ...
... capacitor, typically 1 μF, placed as close as possible to the device VDD lead works best. Placing this decoupling capacitor close to the DRV632 is important for the performance of the amplifier. For filtering lower-frequency noise signals, a 10-μF or greater capacitor placed near the audio power amp ...
Basics of Digital Multimeters
... calibrated and the other is True RMS. Both are designed for periodic type perfectly sinusoidal waveforms and most are AC coupled, meaning that is blocks any DC bias that may effect the measurement. Average Responding voltmeters use a simple circuit to provide a general-purpose voltmeter a low cost m ...
... calibrated and the other is True RMS. Both are designed for periodic type perfectly sinusoidal waveforms and most are AC coupled, meaning that is blocks any DC bias that may effect the measurement. Average Responding voltmeters use a simple circuit to provide a general-purpose voltmeter a low cost m ...
NI USB-6008/6009 User Guide
... Unshielded breadboarding accessory for custom-defined signal conditioning and prototyping. You can use up to two accessories per device. ...
... Unshielded breadboarding accessory for custom-defined signal conditioning and prototyping. You can use up to two accessories per device. ...
AE-2 Draft of Section 22 9/24/08
... withstand a selection of test transients defined in this section which are intended to represent the induced effects of lightning. The waveforms and levels, and the pass/fail criteria for equipment performance during the test shall be listed in the applicable equipment specification. Two groups of t ...
... withstand a selection of test transients defined in this section which are intended to represent the induced effects of lightning. The waveforms and levels, and the pass/fail criteria for equipment performance during the test shall be listed in the applicable equipment specification. Two groups of t ...
DN2.49x - 16 channel 16 bit digitizerNETBOX up to 60 MS/s
... run own programs on a small and remote data acquisition system. The digitizerNETBOX/ generatorNETBOX is enhanced by more memory, a powerful CPU, a freely accessable internal SSD and a remote software development access method. The digitizerNETBOX/generatorNETBOX can either run connected to LAN or it ...
... run own programs on a small and remote data acquisition system. The digitizerNETBOX/ generatorNETBOX is enhanced by more memory, a powerful CPU, a freely accessable internal SSD and a remote software development access method. The digitizerNETBOX/generatorNETBOX can either run connected to LAN or it ...
LM61 2.7-V, SOT-23 or TO-92 Temperature Sensor (Rev. J)
... specified conditions of voltage, current, and temperature (expressed in °C). Nonlinearity is defined as the deviation of the output-voltage-versus-temperature curve from the best-fit straight line, over the device's rated temperature range. Regulation is measured at constant junction temperature, us ...
... specified conditions of voltage, current, and temperature (expressed in °C). Nonlinearity is defined as the deviation of the output-voltage-versus-temperature curve from the best-fit straight line, over the device's rated temperature range. Regulation is measured at constant junction temperature, us ...
DTC P0700 - JustAnswer
... observed from the Freeze Frame/Failure Records data. Circuit/System Testing Important: Additional DTCs may set when disconnecting the automatic transmission inline 20-way connector. 1. Ignition OFF, disconnect the automatic transmission (AT) inline 20-way connector at the transmission. 2. Install th ...
... observed from the Freeze Frame/Failure Records data. Circuit/System Testing Important: Additional DTCs may set when disconnecting the automatic transmission inline 20-way connector. 1. Ignition OFF, disconnect the automatic transmission (AT) inline 20-way connector at the transmission. 2. Install th ...
STP 3 & 4
... b. Loss of one RMU local area cabinet implementing the ECFs. c. Loss of one CMU control area cabinet implementing the ECFs. ...
... b. Loss of one RMU local area cabinet implementing the ECFs. c. Loss of one CMU control area cabinet implementing the ECFs. ...
DS90LV012A / DS90LT012A 3V LVDS Single
... To insure that any noise is seen as common-mode and not differential, a balanced interconnect should be used. Twisted pair cable will offer better balance than flat ribbon cable. 3. Shorted Inputs. If a fault condition occurs that shorts the receiver inputs together, thus resulting in a 0V different ...
... To insure that any noise is seen as common-mode and not differential, a balanced interconnect should be used. Twisted pair cable will offer better balance than flat ribbon cable. 3. Shorted Inputs. If a fault condition occurs that shorts the receiver inputs together, thus resulting in a 0V different ...
IPC APEX 2013
... PCBs are sensitive to environmental conditions. This behaviour is primarily due to the fact that polymeric materials absorb moisture over time. This absorption can activate conductive contaminants on the substrate surface or in the base material of the substrate. [4] Currently when considering the i ...
... PCBs are sensitive to environmental conditions. This behaviour is primarily due to the fact that polymeric materials absorb moisture over time. This absorption can activate conductive contaminants on the substrate surface or in the base material of the substrate. [4] Currently when considering the i ...
Power Supply Rejection Ratio Measurement
... OMICRON Lab is a division of OMICRON electronics specialized in providing Smart Measurement Solutions to professionals such as scientists, engineers and teachers engaged in the field of electronics. It simplifies measurement tasks and provides its customers with more time to focus on their real busi ...
... OMICRON Lab is a division of OMICRON electronics specialized in providing Smart Measurement Solutions to professionals such as scientists, engineers and teachers engaged in the field of electronics. It simplifies measurement tasks and provides its customers with more time to focus on their real busi ...
SNx4HC05 Inverters With Open-Drain Outputs
... The power supply can be any voltage between the minimum and maximum supply voltage rating located in the Recommended Operating Conditions. Each VCC terminal should have a good bypass capacitor to prevent power disturbance. For devices with a single supply, TI recommends a 0.1-µF capacitor. If there ...
... The power supply can be any voltage between the minimum and maximum supply voltage rating located in the Recommended Operating Conditions. Each VCC terminal should have a good bypass capacitor to prevent power disturbance. For devices with a single supply, TI recommends a 0.1-µF capacitor. If there ...
MN270001EN
... level, and, when the source-side protective device opens to de-energize the circuit, the sectionalizer counts the overcurrent interruption. Depending upon the coordination scheme, the sectionalizer will open during the first, second, or third open interval of the fault interrupting device to isolate ...
... level, and, when the source-side protective device opens to de-energize the circuit, the sectionalizer counts the overcurrent interruption. Depending upon the coordination scheme, the sectionalizer will open during the first, second, or third open interval of the fault interrupting device to isolate ...
Automatic test equipment

Automatic or automated test equipment (ATE) is any apparatus that performs tests on a device, known as the Device Under Test (DUT), Equipment Under Test (EUT) or Unit Under Test (UUT), using automation to quickly perform measurements and evaluate the test results. An ATE can be a simple computer controlled digital multimeter, or a complicated system containing dozens of complex test instruments (real or simulated electronic test equipment) capable of automatically testing and diagnosing faults in sophisticated electronic packaged parts or on Wafer testing, including System-On-Chips and Integrated circuits.