Fundamentals of Fast Pulsed IV Measurement
... even if the node is held at a constant voltage • If you must use SMUs, then only connect them to terminals where there is little or no current flow • Also if using SMUs, make sure that they are set to their maximum current range for fastest response ...
... even if the node is held at a constant voltage • If you must use SMUs, then only connect them to terminals where there is little or no current flow • Also if using SMUs, make sure that they are set to their maximum current range for fastest response ...
targa ii - Lion Precision
... The QuikChek Test Fixture contains an integral fiber-optic laser tachometer, a 0.250" locating pin, and a sensor mount that precisely positions the runout sensor for measurement and prevents sensor damage from the rotating gage pin. Preparing a Machine to use the QuikChek The QuikChek Test Fixture h ...
... The QuikChek Test Fixture contains an integral fiber-optic laser tachometer, a 0.250" locating pin, and a sensor mount that precisely positions the runout sensor for measurement and prevents sensor damage from the rotating gage pin. Preparing a Machine to use the QuikChek The QuikChek Test Fixture h ...
PMBus™ Power Syste em Management Pr rotocol
... In no event will any specification co-owner be liable to any other party for any loss of profits, loss of use, incidental, consequential, indirect, or special damages arising out of this specification, whether or not such party had advance notice of the possibility of such damages. Further, no warra ...
... In no event will any specification co-owner be liable to any other party for any loss of profits, loss of use, incidental, consequential, indirect, or special damages arising out of this specification, whether or not such party had advance notice of the possibility of such damages. Further, no warra ...
Evaluates: DS1854/DS1857/DS1858/DS1859 Fiber Optic Monitor and Control Evaluation Kit General Description Features
... Kit, use the jumpers/test points labeled “58” when evaluating the DS1859. Check our FTP site for the latest version of the EV Kit software. Jumpers are present to allow the pins that can be digital inputs to be connected to VCC or GND. For any given device, some of the pins will be analog inputs or ...
... Kit, use the jumpers/test points labeled “58” when evaluating the DS1859. Check our FTP site for the latest version of the EV Kit software. Jumpers are present to allow the pins that can be digital inputs to be connected to VCC or GND. For any given device, some of the pins will be analog inputs or ...
iWISE™ QUAD AM Grade 3 QUAD PIR Wall Mount with Anti
... RISCO Group and its subsidiaries and affiliates ("Seller") warrants its products to be free from defects in materials and workmanship under normal use for 12 months from the date of production. Because Seller does not install or connect the product and because the product may be used in conjunction ...
... RISCO Group and its subsidiaries and affiliates ("Seller") warrants its products to be free from defects in materials and workmanship under normal use for 12 months from the date of production. Because Seller does not install or connect the product and because the product may be used in conjunction ...
A) Resistance, Voltage and Current Measurement using Analog
... Procedure of measurement ~Identify the parameter / variable to be measured and how to record the result. Characteristic of parameter ~ Should know the parameter that is to be measured: ac, dc, volt, current, frequency, etc. Quality ~ The capability of the instrument; the measurement knowledge and su ...
... Procedure of measurement ~Identify the parameter / variable to be measured and how to record the result. Characteristic of parameter ~ Should know the parameter that is to be measured: ac, dc, volt, current, frequency, etc. Quality ~ The capability of the instrument; the measurement knowledge and su ...
IEEE-NFPA Small Wire Report
... conductors for branch circuits was divided into two major categories: verification of overload protection, and verification of short-circuit protection. Following each test, the conductor was visually inspected, then subjected to dielectric testing per UL83, section 27. A. Verification of Short-Circ ...
... conductors for branch circuits was divided into two major categories: verification of overload protection, and verification of short-circuit protection. Following each test, the conductor was visually inspected, then subjected to dielectric testing per UL83, section 27. A. Verification of Short-Circ ...
TBU white paper
... length of time (more than microseconds). Therefore, equipment protection requires a shunt protector that: 1) can react fast enough to allow less than these values from reaching the equipment, and 2) can subsequently short circuit and protect the interface from a surge which may peak on the order of ...
... length of time (more than microseconds). Therefore, equipment protection requires a shunt protector that: 1) can react fast enough to allow less than these values from reaching the equipment, and 2) can subsequently short circuit and protect the interface from a surge which may peak on the order of ...
A new 650V Super Junction Device with rugged body diode... and soft switching applications
... Infineon’s new CoolMOS™ CFD2 device, offers the lowest Rdson combined with a high blocking voltage of 650V. This new device features also a very low reverse recovery charge combined with a robust integral body diode. A specification of the max-values of the Qrr and trr will be available in the datas ...
... Infineon’s new CoolMOS™ CFD2 device, offers the lowest Rdson combined with a high blocking voltage of 650V. This new device features also a very low reverse recovery charge combined with a robust integral body diode. A specification of the max-values of the Qrr and trr will be available in the datas ...
Keysight Technologies Right Load Switching and Simulation Design
... For a typical mechatronic device under test (DUT) such as engine control unit (ECU), it usually has 200 to 450 pins. To make the situation tougher, this kind of DUT usually involves high power testing with many pins that carry current of more than 5 Amps. By taking the ECU example, to check pin by p ...
... For a typical mechatronic device under test (DUT) such as engine control unit (ECU), it usually has 200 to 450 pins. To make the situation tougher, this kind of DUT usually involves high power testing with many pins that carry current of more than 5 Amps. By taking the ECU example, to check pin by p ...
UCC5628 数据资料 dataSheet 下载
... obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to TI’s terms and conditions of sale supplied at the time of order acknowledgment. TI warrants performance of its hardware products to the speci ...
... obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to TI’s terms and conditions of sale supplied at the time of order acknowledgment. TI warrants performance of its hardware products to the speci ...
USB Dedicated Charging Port Controller (Rev. C)
... line and reads the voltage input on its D– line. The portable device concludes it is connected to a SDP if the voltage is less than the nominal data detect voltage of 0.3 V. The portable device concludes that it is connected to a Charging Port if the D– voltage is greater than the nominal data detec ...
... line and reads the voltage input on its D– line. The portable device concludes it is connected to a SDP if the voltage is less than the nominal data detect voltage of 0.3 V. The portable device concludes that it is connected to a Charging Port if the D– voltage is greater than the nominal data detec ...
Mid-Term Report (March 20)
... driven by the MAX3287 laser driver built by MAXIM. The receiver will utilize the MAX3266 Transimpedance Amplifier (TIA) and MAX3264 Limiting Amplifier, both also created by MAXIM. The fiber optic cable that will be used will be 62.5µm width multi-mode fiber. The VCSEL used will be SC connectorized ( ...
... driven by the MAX3287 laser driver built by MAXIM. The receiver will utilize the MAX3266 Transimpedance Amplifier (TIA) and MAX3264 Limiting Amplifier, both also created by MAXIM. The fiber optic cable that will be used will be 62.5µm width multi-mode fiber. The VCSEL used will be SC connectorized ( ...
SN75ALS164 数据资料 dataSheet 下载
... The SN75ALS164 eight-channel general-purpose interface bus transceiver is a monolithic, high-speed, advanced low-power Schottky device designed to meet the requirements of IEEE Standard 488-1978. Each transceiver is designed to provide the bus-management and data-transfer signals between operating u ...
... The SN75ALS164 eight-channel general-purpose interface bus transceiver is a monolithic, high-speed, advanced low-power Schottky device designed to meet the requirements of IEEE Standard 488-1978. Each transceiver is designed to provide the bus-management and data-transfer signals between operating u ...
REGULATORY GUIDE
... needed to operate electrical equipment and they transmit signals to and from the various devices used to perform safety functions and accident mitigation in a nuclear power plant. Despite their importance, cables typically receive little attention because they are considered passive, long-lived comp ...
... needed to operate electrical equipment and they transmit signals to and from the various devices used to perform safety functions and accident mitigation in a nuclear power plant. Despite their importance, cables typically receive little attention because they are considered passive, long-lived comp ...
TR41.3.6-02-11-007-(word) - Telecommunications Industry
... For the purposes of this Standard, the following definitions apply. Line Idle: A state of the CPE line when all connected CPE are On-Hook. ...
... For the purposes of this Standard, the following definitions apply. Line Idle: A state of the CPE line when all connected CPE are On-Hook. ...
Automatic test equipment

Automatic or automated test equipment (ATE) is any apparatus that performs tests on a device, known as the Device Under Test (DUT), Equipment Under Test (EUT) or Unit Under Test (UUT), using automation to quickly perform measurements and evaluate the test results. An ATE can be a simple computer controlled digital multimeter, or a complicated system containing dozens of complex test instruments (real or simulated electronic test equipment) capable of automatically testing and diagnosing faults in sophisticated electronic packaged parts or on Wafer testing, including System-On-Chips and Integrated circuits.