Download CC Series

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Three-phase electric power wikipedia , lookup

Current source wikipedia , lookup

Islanding wikipedia , lookup

Variable-frequency drive wikipedia , lookup

Decibel wikipedia , lookup

Electrification wikipedia , lookup

Rectifier wikipedia , lookup

Stray voltage wikipedia , lookup

Electrical substation wikipedia , lookup

Power engineering wikipedia , lookup

Resistive opto-isolator wikipedia , lookup

Metadyne wikipedia , lookup

Electric battery wikipedia , lookup

LED lamp wikipedia , lookup

Opto-isolator wikipedia , lookup

Surge protector wikipedia , lookup

Electrical ballast wikipedia , lookup

Buck converter wikipedia , lookup

Distribution management system wikipedia , lookup

History of electric power transmission wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Voltage optimisation wikipedia , lookup

AC adapter wikipedia , lookup

Mains electricity wikipedia , lookup

Alternating current wikipedia , lookup

Transcript
Sure-Lites
D es c r iption
The CC Series Contractor's Choice Emergency Lighting Unit is the ideal
choice when a simple installation and a reasonable cost are required. Its
contemporary round corner styling, designer white finish, and consistent
family appearance enables it to blend with any decor. The components
are injection molded from tough polycarbonate materials which resist
discoloration due to age and ultraviolet radiation.
Type
Catalog #
Project
Date
Comments
Prepared by
Spe c ific a tion F ea t u r e s
E le c t r o n i c
Hous i ng Cons t ru ction
Co d e Co mplian ce
- Dual Voltage Input
120/277 VAC, 60Hz
- Line-latching
- Solid-state Voltage
Limited Charger
- Solid-state Switching
- Brownout Circuit
- Low-Voltage Disconnect
- Overload/Short Circuit
Protection
- Test Switch/Power
Indicator Light
- Push-in AC power connectors
facilitate installation
- All components are injectionmolded, color stable, high impact
UL 94-5VA rated polycarbonate
material
- Designer white textured finish
standard; black finish optional
- Components are of snap-fit
construction to facilitate
under 2-minute installation
- Reinforcing ribs throughout
to provide maximum strength
- Tether straps between housing
and mounting plate facilitate
installation
- Cutouts provided in housing for
surface conduit attachment
- Suitable for wall or ceiling
mount applications
- Universal J-box mounting
pattern
- Keyhole mounting slots
- UL 924 Listed
- UL Damp Location Listed
(CC5.SD only)
- Life Safety NFPA 101
- NEC/OSHA
- Most State and Local Codes
Ba t t e r y
- Sealed Lead Calcium,
recombination
- Nickel Cadmium Battery (CC3NC)
- Maintenance-free, long-life
- Full recharge time: 24 hrs. (max.)
- Polarized battery terminals
Warran ty
- Exit: 1-year
- Lead Acid Battery:
5-year pro-rata
- Nickel Cadmium Battery:
15-year pro-rata
CC Series
Head /Lamp Data
- Two heads standard
PAR 36 type heads
- Glare-free lens
- Fully adjustable lamp housing
- High impact polycarbonate
- Matches housing finish
- Optional square and
MR16 heads available
13" [330mm]
Polycarbonate
Contractor's Choice
Sealed Lead Calcium Battery
Sealed Nickel Cadmium
Battery
Emer genc y Ligh ting
4 3/4”
[121mm]
6 3/8” max.
[162mm]
SURE-LITES
17 1/2" max [445mm]
Ele c tr ic a l R a ting s
R a t e d W a t t a g e to 87 1/2% of Rated D.C. Voltage
Model
DC Voltage
1 1/2 Hours
CC5
CC5
CC5NC(1)
CC6
CC6
6
6
6
6
6
27
27
24
32
32
2 Hours
24
24
-
3 Hours
Lamp Information
4 Hours
18
18
-
14
14
-
Type
Wattage
Number
Spacing(3)
Incandescent
MR16
Incandescent
Incandescent
MR16
9
9
9
9
9
29-84
29-145
029-84
29-84
29-145
22.0’
35.0’
22.0’
22.0’
35.0’
Ord er ing I nfor m at i o n
Sample Number: CC5WH
Options 1, 2
MRT =MR16 Lamp Heads
CC5NC
Housing
Finish
WH =White
CC6
BK =Black
A =Ammeter
V =Voltmeter
Series
CC5
Voltage
__=120 / 277V
347 =120/347 VAC
SQ =Square Heads
Accessories
3
4
SD =Self Diagnostics 5, 6
TDM =Time Delay Monitor
7
Cord Set
CSK120
=Cord Set (120 VAC)
Protective Housing
WG1 =Wire Guard
WG2 =Wire Guard (use for heads adjusted at
45 degrees or greater).
VS1 =Polycarbonate Vandal Shield
VS1WP
ENERGY D ATA
Model CC5
Input Current (Max.):
120V = .13A
277V = .06A
347V = .06A
=Polycarbonate Vandal Shield Weather Resistant
Notes:
1 Add as a suffix. 2 Consult your Cooper Lighting Representative for alternate lamps and additional options. 3 MR16 heads 9W Standard CC5, and CC6).
Other lamp wattages available. Consult your Cooper Lighting Rep. 4 Square heads (5.4W Standard). Other lamp wattages available. Consult your Cooper Lighting Rep.
5 CC5SD Standard damp location. 6 CC6, CC5NC not available in SD. 7 Order separately.
Model CC6
Input Current (Max.):
120V = .13A
277V = .06A
347V = .06A
TD505009EN
2016-02-12 10:51:18
C C Series
Ph otom etr ic s
29-84
.
22' Spacing
Illuminance
Values (Fc)
Average=1.55
Illuminance
Average=1.11
Maximum=6.8
Minimum=0.2
Avg/Min
Ratio=7.75
Max/Min
Ratio=34.00
For Standard Fixture: CC5, CC6
29-145
35' Spacing
Values (Fc)
Maximum=7.8
Minimum=0.2
Avg/Min
Ratio=5.55
Max/Min
Ratio=39.00
For Standard Fixture: CC5MRT, CC6MRT
Notes
The “Rule of Thumb” spacing guidelines are designed to achieve 1 foot-candle average and 0.1 foot-candle minimum with a 40:1 maximum/minimum ratio. The corridor used is 100
feet long, 9-foot ceiling with a 6-foot wide walkway and 3-foot path of egress. The reflectances are 80% ceiling, 50% walls and 20% floors. The fixture mounting height is 8.5 feet.
Cooper Lighting assumes no responsibility for local requirements or specific project variables. This is a guideline to be used as a design aid, not as guarantee of any code compliance.
Tec h nic a l D a ta
Lam p s
Sol i d- State Charg er
Lo w-Vo ltage Discon n ect
Designed specifically for emergency lighting
applications, the PAR 36 type design insures
optimum glare-free trapezoidal light distribution
along with horizontal and vertical adjustment by
rotating the lens within the housing.
Supplied with a 120/277 VAC, voltage
regulated solid-state charger. Immediately
upon restoration of AC current after a power
failure, the charger provides a high charge
rate. The charge circuit reacts to the condition
of the battery and alters the rate of charge in
order to maintain peak battery capacity and
maximize battery life. Solid-state construction
recharges the battery following a power failure
in accordance with UL 924.
When the battery’s terminal voltage falls below
80% of the rated voltage, the low-voltage
circuitry disconnects the lighting load. The
disconnect remains in effect until normal utility
power is restored, preventing deep battery
discharge.
H o u sin g C o n s t r u c t i o n
Rugged, durable, injection molded
polycarbonate materials are used throughout
the CC Series Emergency Lighting Units. All
structural components are designed with
reinforcing ribs to add additional rigidity and to
maximize structural integrity. These materials
are impact- and scratch-resistant, and they have
been UV stabilized to resist discoloration due
to age and ultraviolet radiation. All components
are designed to be of snap-fit construction - no
mechanical fasteners - to facilitate installation
in under 2 minutes. The housing contains
hidden tearouts for surface conduit attachment.
The housing is tethered to the mounting
plate freeing both hands to make electrical
connections. The mounting plate has keyhole
mounting slots and a universal mounting
pattern for quick, efficient installation. Any
components required for installation (wirenuts,
wire leads, etc.) are all included with each unit.
All CC Series Units are suitable for wall or
ceiling mount applications.
O v e rl oa d and S ho rt-Circuit P ro tection
The solid-state overload monitoring device in
the DC circuit disconnects the lamp load from
the battery should excessive wattage demands
be made and automatically resets when the
overload or short-circuit is removed. This
overload current protective feature eliminates
the need for fuses or circuit breakers for the DC
load.
Eaton
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.eaton.com/lighting
A test switch permits the activation of the
emergency circuit for a complete operational
system check. The Power Indicator Light
provides assurance that the AC power is on.
S ealed Lead Calciu m B att er y
The fully sealed, long-life, maintenance-free
lead calcium battery is ideal for emergency
lighting applications. These recombinant cycle
batteries typically provide 8 to 10 years of life
and may be operated in any position.
Warranty
Brownou t Circuit
The brownout circuit in Sure-Lites units
monitors the flow of AC current to the unit and
activates the emergency lighting system when
a predetermined reduction of AC power occurs.
This dip in voltage will cause most ballasted
fixtures to extinguish causing loss of normal
lighting even though a total power failure has
not occurred.
Lin e-La t c h e d
Sure-Lites’ line-latched electronic circuitry
makes installation easy and economical. A labor
efficient AC-activated load switch prevents
the lamps from turning on during installation
to a non-energized AC circuit. Line-latching
eliminates the need for a contractor’s return
to a job site to connect the batteries when the
building’s main power is permanently turned
on.
T est S witch /P ower In d ica t o r Lig h t
Sol i d- State T ran sfer
The unit incorporates a solid-state switching
transistor which eliminates corroded and pitted
contacts or mechanical failures associated with
relays. The switching circuit is designed to
detect a loss of AC voltage and automatically
energizes the lamps. Upon restoration of the
AC power, the emergency lamps will switch off
and the charger will automatically recharge the
battery.
Specifications and
dimensions subject to
change without notice.
All Sure-Lites units are backed by a firm oneyear warranty against defect in material and
workmanship (excluding lamps). Maintenancefree, long-life, sealed lead calcium batteries
carry a five-year pro-rata warranty.