Electrical ballast wikipedia , lookup

Opto-isolator wikipedia , lookup

LED lamp wikipedia , lookup

History of electric power transmission wikipedia , lookup

Distribution management system wikipedia , lookup

Buck converter wikipedia , lookup

Voltage optimisation wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Alternating current wikipedia , lookup

Mains electricity wikipedia , lookup

Transcript
COOPER LIGHTING - SURE-LITES ®
DESCRIPTION
Versatile "mini-system" features electronic reliability, quality metal
construction, optimum illumination and attractive compact appearance.
The popular choice for commercial, institutional and public facilities
where moderate loads, economy, ease of installation, safety and
reliability are important. Maximum emergency lighting efficiency is
combined with low profile appearance. The unit of choice for
installations where the size and cost of emergency lighting must be kept
to a minimum without sacrificing dependability or light output.
Type
Catalog #
Project
Date
Comments
Prepared by
S P E C I F I C AT I O N F E AT U R E S
E l e c t ro n i c
B a tte r y
Code Compliance
- Dual Voltage Input
120/277 VAC, 60 Hz
- Line-latching
- Solid-state Voltage Limited
Charger
- Solid-state Switching
- Low-Voltage Disconnect
- Brownout Circuit
- Overload/Short Circuit
Protection
- Test Switch/Power
Indicator Light
- Sealed Lead Calcium,
Recombination (LM1, AA1)
- Maintenance-free, Long-life
- Full Recharge Time,
24-hrs. (max.)
- Polarized Battery Terminals
- UL 924 Listed
- Life Safety NFPA 101
- NEC/OSHA
- Most State and Local Codes
Wa rra n t y
- Unit: 1-year
- Battery: 5-year pro-rata
H o u s i n g C o n s t ru c t i o n
- 22-Gauge Die-Formed Steel
Knockout, Conduit or Cord Set
- Universal J-Box Mounting Pattern
- Keyhole Mounting Slots
H e a d / L a m p Da t a
- Two Heads Standard
- Glare-Free Lens
- Fully Adjustable
- High Impact - Thermoplastic
- Matches Housing Finish
AA
SERIES
ST E E L
DOUBLE HEAD
M E TA L B O DY
9 1/8"
[232mm]
SEALED LEAD
C A L C I U M B AT T E RY
4 1/2"
[114mm]
E M E R G E N CY L I G H T I N G
2 1/4"
[57mm]
4 1/4" [108mm]
2 1/4"
[57mm]
5" max.
[127mm]
4" [102mm]
6 1/8" [156mm]
12 1/4" [311mm]
E L E C T R I C A L R AT I N G S
R a t e d W a t t a g e to 87 1/2% of Rated D.C. Voltage
Model
Battery
AA1
SLC
DC Voltage
3
1 1/2 Hours
6
2 Hours
18
15
3 Hours
10
Lamp Information
4 Hours
8
Type
Wattage
Number
Incandescent
9
29-84
ORDERING INFORMATION
Series
AA1
Notes: 1
Options 1, 2
V=Voltmeter3
Accessories
SD=Self Diagnostics
TDM=Time Delay Monitor
1MSWH=Mounting Shelf, White
4
Mounting Kit
1BRWH=Mounting Brackets (2) White
Protective Housing
E N E R G Y D ATA
Add as a suffix.
WG1=Wire Guard
2
Consult your Cooper Lighting Representative for alternate lamps
and additional options.
VS1=Polycarbonate Vandal Shield
Input Current (Max.):
VS1WP=Polycarbonate Vandal Shield - Weatherproof
120V= .12A
3
Provisions for one meter only.
4
Order separately.
VK1=Voltmeter
Specifications and dimensions subject to change without notice.
Consult your representative for additional options and finishes.
277V= .05A
ADX040995 pc
2010-07-19 11:59:37
AA SERIES
T E C H N I C A L DATA
Heads
S o l i d - S t a te C h a rge r
S o l i d - S t a te Tra n s fe r
The lamp housing is constructed of flameresistant and impact-resistant polycarbonate
injection molded thermoplastic with matching
finish. The three dimensional swivel assembly
permits approximate aiming adjustment from
80° vertical and 358° rotation. The placement is
secured with a lockable pivot mounted on a
rotating base ring.
Supplied with a 120/277 VAC, voltage regulated
solid-state charger. Immediately upon
restoration of AC current after a power failure,
the charger provides a high charge rate. The
charge circuit reacts to the condition of the
battery and alters the rate of charge in order to
maintain peak battery capacity and maximize
battery life. Solid-state construction recharges
the battery following a power failure in
accordance with UL 924.
The unit incorporates a solidstate switching
transistor which eliminates corroded and pitted
contacts or mechanical failures associated with
relays. The switching circuit is designed to
detect a loss of AC voltage and automatically
energizes the lamps. Upon restoration of the AC
power, the emergency lamps will switch off and
the charger will automatically recharge the
battery.
Lamps
Designed specifically for emergency lighting
applications, the PAR 36 sealed beam type
design insures optimum glare-free trapezoidal
light distribution along with horizontal and
vertical adjustment by rotating the lens within
the housing.
Housing
The rugged 22-gauge dieformed steel housing is
finished with white corrosion-resistant polyester
powder coat paint. Cabinet has keyhole
mounting slots and knockouts in rear and side
for AC/DC wiring connections and has universal
mounting pattern.
L i n e - L a t ch e d
Sure-Lites’ line-latched electronic circuitry
makes installation easy and economical. A labor
efficient AC-activated load switch prevents the
lamps from turning on during installation to a
non-energized AC circuit. Line-latching
eliminates the need for a contractor’s return to a
job site to connect the batteries when the
building’s main power is permanently turned
on.
L ow- Vo l t a ge D i s c o n n e c t
O ve rl o a d a n d S h o rt - C i rc u i t P ro te c t i o n
The solid-state overload monitoring device in
the DC circuit disconnects the lamp load from
the battery should excessive wattage demands
be made and automatically resets when the
overload or short circuit is removed. This
overload current protective feature eliminates
the need for fuses or circuit breakers for the DC
load.
B row n o u t C i rc u i t
The brownout circuit in Sure-Lites’ units
monitors the flow of AC current to the unit and
activates the emergency lighting system when a
predetermined reduction of AC power occurs.
This dip in voltage will cause most ballasted
fixtures to extinguish causing loss of normal
lighting even though a total power failure has
not occurred.
When the battery’s terminal voltage falls below
80% of the rated voltage, the low-voltage
circuitry disconnects the lighting load. The
disconnect remains in effect until normal utility
power is restored, preventing deep battery
discharge.
Te s t Sw i t ch / Powe r I n d i c a to r L i g h t
Conveniently located combination Test
Switch/Power Indicator Light allows for manual
verification of proper operation of the transfer
circuit and emergency lamps.
S e a l e d L e a d C a l c i u m B a tte r y
The fully sealed, long-life, maintenance-free
lead calcium battery is ideal for emergency
lighting applications. These recombinant cycle
batteries typically provide eight to ten years of
life and may be operated in any position.
Wa rra n t y
All Sure-Lites’ units are backed by a firm oneyear warranty against defect in material and
workmanship (excluding lamps). Maintenancefree, long-life, sealed lead calcium batteries
carry a five-year pro-rata warranty.
Specifications and dimensions subject to change without notice.
Sure-Lites • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801
ADX040995 pc
2010-07-19 11:59:37
2010-08-11 12:08:42