Download Test the Withstand Voltage of Medical Electrical Equipment

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Stepper motor wikipedia , lookup

Power engineering wikipedia , lookup

Ground (electricity) wikipedia , lookup

Pulse-width modulation wikipedia , lookup

Power inverter wikipedia , lookup

Electromagnetic compatibility wikipedia , lookup

Electrical ballast wikipedia , lookup

Variable-frequency drive wikipedia , lookup

Immunity-aware programming wikipedia , lookup

Three-phase electric power wikipedia , lookup

Multimeter wikipedia , lookup

Islanding wikipedia , lookup

Current source wikipedia , lookup

Automatic test equipment wikipedia , lookup

History of electric power transmission wikipedia , lookup

Metadyne wikipedia , lookup

Ohm's law wikipedia , lookup

Electrical substation wikipedia , lookup

Portable appliance testing wikipedia , lookup

Rectifier wikipedia , lookup

Power electronics wikipedia , lookup

Resistive opto-isolator wikipedia , lookup

Distribution management system wikipedia , lookup

Triode wikipedia , lookup

Schmitt trigger wikipedia , lookup

Power MOSFET wikipedia , lookup

Opto-isolator wikipedia , lookup

Buck converter wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Surge protector wikipedia , lookup

Voltage regulator wikipedia , lookup

Alternating current wikipedia , lookup

Stray voltage wikipedia , lookup

Voltage optimisation wikipedia , lookup

Mains electricity wikipedia , lookup

Transcript
Medical Equipment
QA, Inspection/Manufacturing
Test the Withstand Voltage of Medical Electrical Equipment
Generate the applied voltage for the withstand voltage test automatically using
the ramp-time function.
■ Highlights
・A ramp-time function can be used for the withstand voltage test of medical electrical equipment in
accordance with the procedure in which less than half the voltage of the specified value is applied
and then the voltage is increased gradually for 10 seconds to the specified value, maintained for
1 minute, and then reduced to less than half of the specified value for 10 seconds.
・A contact check function to detect a broken test lead wire or contact failure improves test reliability.
・A built-in stabilized power supply prevents changes in the test voltage caused by power supply voltage
changes and improves the test reliability.
Time/Voltage of Withstanding voltage test
Test voltage (V)
Medical Electrical Equipment
3174 AC AUTOMATIC
INSULATION/WITHSTANDING HiTESTER
Test time (s)
●Example of setting the ramp-up and ramp-down of the 3174 AC Automatic Insulation/Withstanding HiTester.
・ The time during which the output voltage increases to the initial voltage is “0.3 s.”
・ The initial voltage is a “value equivalent to 50% of the specified voltage to be tested.”
・ The ramp-up time is “10 s.”
・ The test voltage time is “60 s.”
・ The test voltage is the “specified voltage to be tested.”
・ The ramp-down time is “10 s.”
・ The ramp-down end voltage is a “value equivalent to 50% of the specified voltage to be tested.”
Products used
・AC AUTOMATIC INSULATION/WITHSTANDING HiTESTER 3174
・AC AUTOMATIC INSULATION/WITHSTANDING HiTESTER 3174-01 (GP-IB interface included)
※ To perform a contact check, the 9615 Replacement HV Test Lead Set is required.
Information valid as of February 2009.
Specifications are subject to change and revision without notice.
Y0010-E00
February 2009