* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Test the Withstand Voltage of Medical Electrical Equipment
Stepper motor wikipedia , lookup
Power engineering wikipedia , lookup
Ground (electricity) wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Power inverter wikipedia , lookup
Electromagnetic compatibility wikipedia , lookup
Electrical ballast wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Three-phase electric power wikipedia , lookup
Current source wikipedia , lookup
Automatic test equipment wikipedia , lookup
History of electric power transmission wikipedia , lookup
Electrical substation wikipedia , lookup
Portable appliance testing wikipedia , lookup
Power electronics wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Distribution management system wikipedia , lookup
Schmitt trigger wikipedia , lookup
Power MOSFET wikipedia , lookup
Opto-isolator wikipedia , lookup
Buck converter wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Surge protector wikipedia , lookup
Voltage regulator wikipedia , lookup
Alternating current wikipedia , lookup
Stray voltage wikipedia , lookup
Medical Equipment QA, Inspection/Manufacturing Test the Withstand Voltage of Medical Electrical Equipment Generate the applied voltage for the withstand voltage test automatically using the ramp-time function. ■ Highlights ・A ramp-time function can be used for the withstand voltage test of medical electrical equipment in accordance with the procedure in which less than half the voltage of the specified value is applied and then the voltage is increased gradually for 10 seconds to the specified value, maintained for 1 minute, and then reduced to less than half of the specified value for 10 seconds. ・A contact check function to detect a broken test lead wire or contact failure improves test reliability. ・A built-in stabilized power supply prevents changes in the test voltage caused by power supply voltage changes and improves the test reliability. Time/Voltage of Withstanding voltage test Test voltage (V) Medical Electrical Equipment 3174 AC AUTOMATIC INSULATION/WITHSTANDING HiTESTER Test time (s) ●Example of setting the ramp-up and ramp-down of the 3174 AC Automatic Insulation/Withstanding HiTester. ・ The time during which the output voltage increases to the initial voltage is “0.3 s.” ・ The initial voltage is a “value equivalent to 50% of the specified voltage to be tested.” ・ The ramp-up time is “10 s.” ・ The test voltage time is “60 s.” ・ The test voltage is the “specified voltage to be tested.” ・ The ramp-down time is “10 s.” ・ The ramp-down end voltage is a “value equivalent to 50% of the specified voltage to be tested.” Products used ・AC AUTOMATIC INSULATION/WITHSTANDING HiTESTER 3174 ・AC AUTOMATIC INSULATION/WITHSTANDING HiTESTER 3174-01 (GP-IB interface included) ※ To perform a contact check, the 9615 Replacement HV Test Lead Set is required. Information valid as of February 2009. Specifications are subject to change and revision without notice. Y0010-E00 February 2009