* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Diapositiva 1
Survey
Document related concepts
Soil horizon wikipedia , lookup
Soil respiration wikipedia , lookup
Soil erosion wikipedia , lookup
Crop rotation wikipedia , lookup
Terra preta wikipedia , lookup
Canadian system of soil classification wikipedia , lookup
Soil compaction (agriculture) wikipedia , lookup
No-till farming wikipedia , lookup
Surface runoff wikipedia , lookup
Soil food web wikipedia , lookup
Soil salinity control wikipedia , lookup
Transcript
ESSEE 4 Palić, Serbia, 17 – 22 Sept., 2006 ELECTROCHEMICAL REMEDIATION Achille De Battisti Laboratory of Elettrochemistry Department of Chemistry of the University of Ferrara Targets: Non-destructive removal of pollutants from soils - Detoxification/sterilization of industrial wastewaters, landfill leachates, swimming-pool water, water in food industry. - Cold incineration of organic wastes and disgregation of radioactive residuals. - Quality improvement of potable water, detoxification/sterilization of groundwaters Soils: Electrochemical (electrokinetic) extraction of pollutants Methods: Imposition of potential gradients across the soil portion to be remediated polarizing suitably positioned electrodes Primary effects: displacement of charged species (electromigration, electro-osmosis), and neutral species (electro-osmosis). Secondary effects: Accumulation of pollutants in electrodic spaces, followed by abatement. Soils: Electrochemical (electrokinetic) remediation Advantages: in situ methods, substantially non-destructive, no chemicals used, low energy consumption (e.g..: few tens of Volts and currents of the order of few Amperes); flexibility (e.g.: D.C. , A.C. polarization), Disadvantages: possible incompatibility with the specific features of the site to be reclamated, problems of stability for metallic structures in the soil. Electrokinetic phenomena: some general aspects Outer Helmholtz Plane + + + + S + + + + + + + + 0 + Sharing plane Solution flow 2 - Further information on an electrified interfase interphase 0e x or 2e x 1/2 RT 1 2 2 8 F c z i i = potential at the distance x from the charged wall 0= potential at the charged wall 2= potential at the Outer Helmholtz Plane (OHP) = permittivity of the liquid phase -1= diffuse-layer “thickness” transit plane v eo 1 ve + + + + + + + + charge plane (qd) -1 - - - - - surface of the immobile solid with charge density -qd Flow of electrolyte solutions through capillary channels with charged surface Elettro-osmosis Electrode Electroosmotic flow Electrolyte solution Phenomenological equation v e a1P a2E Ve=electro-osmotic flow rate; P=pressure gradient; E=campo elettrico Electrode Flow of electrolyte solutions through capillary channels with charged surface Streaming currents and potentials Electrode Electrokinetic current Electrolyte solution Phenomenological equation: j a3P a4E j = current density; P=pressure gradient; E=electric field Electrode Qualitative representation of the profile of the electro-osmotic flow rate in a capillary channel - - - - - - - - - - - - + + + + + + + + + + + + + E + + + + + + + + + + + + + - - - - - - - - - - - - v Simplified scheme of a particle plug with surface ionogenic groups: fixed solid-mobile solution + + - + - - ++ + + + + + + + + + -++ - - + + - ++ + -+ + + + + + -+ - ++ ++ + + + - + ++ + -+ Hydrostatic pressure gradients across the plug, cause a displacement of a fraction of the volume-charge in the direction of the fluid flow. As a consequence, streaming currents and potentials are measured In the hypotesis that the shear plane and capillary surface cohincide: 0 a 2 a3 From former definitions and developments we have also: qd C 1 0 qd 0 a2 a3 1 Transport due to the electric field: electro-osmosis v e keEA Ve = electro-osmotic flow rate ue = electro-osmotic velocity Ke = electro-osmotic permeability coefficient E = electric field A = total cross-sectional area E ue EnA ve n ke Some considerations on the electro-osmotic permeability coefficient The electro-osmotic permeability coefficient, ke is independent from the pore diameter, at variance with the hydraulic permeability coefficient, kh. The experimental values of ke do not depend on soil nature and change within a very narrow range, between 10-9 e 10-8 m2 V-1 s-1, while kh ranges between 10-13 e 10-5 m s-1. An electric gradient is more effective than an hydraulic one in fine-grained soils. Electro-osmotic flow is well controlled, being confined within the area across which electric field is active Being for a given soil negative, the electro-osmotic flow is addressed toward the cathode. Transport under the effect of electric field: electromigration The dependence of ion elettromigration on potential gradient, in a capillary: vm E Where vm is the ion velocity, is the ionic mobility, assuming values typically around 3.10-8 m2 v-1 s-1 (about one order of magnitude higher for H+ e OH- ) Electromigration is affected by electric field, and ionic strength. Important factors in electrokinetic remediation Soil chemistry, or soil-contaminant interaction: The kinetics of the removal of contaminants is bound to adsorption phenomena, ion-exchange, buffering capacity Water content: inhomogeneous distribution of humidiy and consolidation may take place during an electrokinetic Soil structure: clogging of the soil porous texture and blocking of the electro-osmotic flow may take place due to hydroxide (presence of heavy metals). Positioning of the electrodes and electrode structure: Solidity of the structure, easy workability, chemical stability, costs, are major actors. graphite, activated Titanium are electrode materials of practical interest. Optimization of the electro-osmotic process -use of “washing” liquids , like water, diluite NaCl solutions. -control of soil pH by means of buffering substances. -washing of electrodic compartments, by addition of water/water solutions. -addition of complexing agents, for heavy-metal removal -weak alkalinization and/or adition of surfactants for the removal of strongly adsorbed organic contaminants Simple equipment for Studies in electrokinetic soil remediation Electrode distribution (bench scale to commercial installations Electrode distribution (bench scale to commercial installations Electrokinetic soil remediation: time required/1 u v i ke E R dc V = rate of species transport (or velocity: LT-1) i*= effective ionic mobility L2T-1V-1 Ke = coefficient of electroosmotic permeability L2T-1V-1 Rdc= delaying factor (dimensionless, depends on soil type, pH, and contaminant nature. Accounts for contaminant desorption and dissolution. E = the electric gradient V L-1 Electrokinetic soil remediation: time required/2 The remediation time TE required for a given contaminant in a soil may be expressed as: LE/v, where LE is the spacing between electrodes of opposite polarity 1 LE TE E σ* = effective soil conductivity (siemens m-1) β is a lumped property of the contaminant and of the soil (L3 C-1), similar to transference numbers in electrochemistry, but it also accounts for electroosmosis, soil conditions and retardation caused by geochemical reaction: i k e / R dc Electrokinetic soil remediation: time required/3 β is a fundamental parameter in electrokinetic soil remediation. Its values typically range within 1.10-9 and 1.10-6 m3 C-1 If the remediation time has to be calculated on the basis of current density applied across the soil, then we have: TE 1 LE Id Where Id is the electric current density = I/A (amp L-2), I is the total current and A the cross-sectional area of the soil treated. PERMEABLE REACTIVE BARRIERS Groundwater treatment • Definition and methodology PRB normal with respect to groundwater flow. Containing reactive material Veduta schematica dell’installazione di una PRB Funnel-and-gate and continuous PRB Encouraging number of commercial installations: the situation in USA PERMEABLE REACTIVE BARRIERS Reductive degradation of organochloro componds with oxidation of Fe0 a Fe2+ Fe0 + RCl + H+ Fe2+ + RH + Cl2Fe0 + O2 + 2 H2O 2 Fe2+ + 4 OH– Fe3+ + 3 OH– Fe(OH)3 (S) Fe0+ 2H2O Fe2+ + H2 + 2OH– Fe2+ + 2OH– Fe(OH)2 (S) Aerobic environment Anaerobic environment important!! Hydraulic permeability and reactivity of the barrier from PRB to Electrochemical Reactor Possible efficiency problem: Barrier aging and degradation Electrochemically generated Fenton reactant O2 cathodic reduction in presence of Fe2+ CATHODE Fe²++Reazione H2O2 Fe³+ + .OH + OHFe³+ +diH2Fenton O2 Fe²+ + .OOH + H+ Further oxidation ANODE Oxidative attack to organic substrates Hybrid Processes - Synergism has been observed in the application of electric fields and hydraulic pressure gradients (removal of heavy metals from da mixtures sand/process-sludge -Similar observations in the use of acoustic treatments coupled with the electro-osmotic one (removal of decane, Zn, Cd, from clays) -Electrodialysis: The efficiency of removal of heavy metals and maintenance of treated soil pH can be improved making use of ion-exchange membranes. -Bioremediation: The displacement of nutrients and colonies of microorganisms under the action of electric fields may favour the removal of complex organic species. -Fitoremediation: the transfer of the pollutant to the treated area accelerates the removal process. Suggested reference: I.K. Iskander, Environmental Restoration of Metals-Contaminated Soils Lewis Publ., London, 2001