* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download 3 Phase circuits, Single-phase transformer circuit model, and 3
Stepper motor wikipedia , lookup
Spark-gap transmitter wikipedia , lookup
Mercury-arc valve wikipedia , lookup
Electric power system wikipedia , lookup
Power factor wikipedia , lookup
Electrification wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Ground (electricity) wikipedia , lookup
Electrical ballast wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Power inverter wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Amtrak's 25 Hz traction power system wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Current source wikipedia , lookup
Power engineering wikipedia , lookup
Earthing system wikipedia , lookup
Power MOSFET wikipedia , lookup
Power electronics wikipedia , lookup
Single-wire earth return wikipedia , lookup
Voltage regulator wikipedia , lookup
Transformer wikipedia , lookup
Surge protector wikipedia , lookup
Electrical substation wikipedia , lookup
Opto-isolator wikipedia , lookup
History of electric power transmission wikipedia , lookup
Stray voltage wikipedia , lookup
Transformer types wikipedia , lookup
Buck converter wikipedia , lookup
Three-phase electric power wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Voltage optimisation wikipedia , lookup
ECE 432 Homework Set 2 Transformer Note: unless stated otherwise, all values of voltages and currents are rms values 1. A 10 kVA, 480/120 V, 60 Hz, single phase, transformer has the following open‐circuit and short‐circuit test data: Test Voltage ( V) Current Power (A) (W) Open‐Circuit : measurements taken on the 120 V side 120 12 102 Short‐Circuit: measurements taken on the 480V side 35 20.833 153 Note, all voltages and currents are rms values. a) Ignoring magnetizing and core losses and using just the short‐circuit test data, determine the total series resistive and leakage reactance values referred to the 480V side of its equivalent circuit representation. What would be the corresponding values when referred to the 120V side? b) Again, ignoring magnetizing and core losses as in part a) above, determine the high side supply voltage needed to deliver rated 120 V to a 10 kVA load at 0.8 power factor lagging. Holding the high‐side supply voltage fixed at that value, what voltage regulation in percent will the terminal voltage at the low voltage side experience when the load is disconnected? c) Estimate the efficiency of the transformer operating at rated output voltage delivering rated kVA at 0.8 power factor lagging using both open and short‐circuit test data. 2. The above single-line diagram shows a factory load supplied via a step-down transformer from a distribution network. The distribution network is represented by a simple Thevenin equivalent: a 3-phase, 13.2 kV voltage source and a source impedance Zs = j20 . The transformer, with its reactances in per unit on its own rating, and the three-phase load are as follows: 3-phase transformer T: 1500 kVA, 13.2kV/600V, leakage reactance of 0.1 per unit on its own rating. 3-phase factory load: 1200 kW, 0.8 power factor lagging at 600 V Unless stated otherwise, with 3-phase equipment, the power values are total 3-phase and the voltages are line-to-line rms. a) Using a common Sbase = 1500 kVA and a Vbas e of 600V on the load side of the transformer, determine the base impedance on each side of the transformer. b) Sketch an equivalent single-phase circuit representation of the distribution network and factory load showing all parameters on the chosen per unit system. c) For a balanced operating condition where the line-to-line voltage on the factory side is 600V, determine the per unit value of the Thevenin voltage and it’s corresponding line-to-neutral voltage in Volts; the current supplied by the Thevenin source in Amps at the given load condition.