* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Special Equipment - newton trasformatori
Power factor wikipedia , lookup
War of the currents wikipedia , lookup
Mercury-arc valve wikipedia , lookup
Audio power wikipedia , lookup
Electrical ballast wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Ground (electricity) wikipedia , lookup
Current source wikipedia , lookup
Electric power system wikipedia , lookup
Electrification wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Power inverter wikipedia , lookup
Power MOSFET wikipedia , lookup
Single-wire earth return wikipedia , lookup
Surge protector wikipedia , lookup
Buck converter wikipedia , lookup
Distribution management system wikipedia , lookup
Power electronics wikipedia , lookup
Voltage regulator wikipedia , lookup
Amtrak's 25 Hz traction power system wikipedia , lookup
Electrical substation wikipedia , lookup
Power engineering wikipedia , lookup
Stray voltage wikipedia , lookup
Opto-isolator wikipedia , lookup
Transformer wikipedia , lookup
Three-phase electric power wikipedia , lookup
Voltage optimisation wikipedia , lookup
History of electric power transmission wikipedia , lookup
Switched-mode power supply wikipedia , lookup
The Special Equipment Newton Trasformatori SpA, already leading company in manufacture of distribution transformers, in the recent years had the opportunity to expand its range of products , dedicated to design and manufacture special components, proposing itself more and more as reference supplier for electric and electromagnetic equipment. Thanks to the experience arising from the provision of special components, made in recent years in countries that are particularly demanding as those of Northern Europe, we are now able to offer high quality products with an excellent quality/price , with a lead time very reduced. Below a brief description of main components, which represents only few items of a wider range. • Earth Transformers. The former of neutral represent a special kind of transformer , specifically used to create the neutral point , on the networks where the neutral point doesn’t exists. Voltage till 125 kV Earth current till 1000 A Vectorial Group : ZN, ZNyn11, ZNzn0, ZNyn11+d, Yy0+d NEWTON TRASFORMATORI S.p.A Sede Legale, Amministrativa e Stabilimenti : Via dei Gelsi, 15 - Località Pian dei Peschi - 53036 POGGIBONSI (SI) - Tel.+39.0577.979681 r.a. - Fax +39.0577.979678 Cod. Fisc. e P. IVA 00898060520 capitale sociale 2.000.000,00 i.v. e-mail: [email protected] www.newtontrasformatori.it • Rectifier Transformers & Cyclo-converter Transformers This particular kind of transformers is used to give power to static components and , which, for this reason, they can be affected by harmonics which are different from the main one; increasing the working temperature of transformer. In order to compensate the relevant increase of temperature, and consequently the higher level of losses, the design has to be done increasing the dimensions of the transformer, to allow a better cooling phase. Operating Voltage till 125 kV Current level till 25.000 ampere Oil immersed and cast resin design Multi phases secondaries (3-6-12-24 or according customer requests.) NEWTON TRASFORMATORI S.p.A Sede Legale, Amministrativa e Stabilimenti : Via dei Gelsi, 15 - Località Pian dei Peschi - 53036 POGGIBONSI (SI) - Tel.+39.0577.979681 r.a. - Fax +39.0577.979678 Cod. Fisc. e P. IVA 00898060520 capitale sociale 2.000.000,00 i.v. e-mail: [email protected] www.newtontrasformatori.it • Power Reactors & Shunt Reactors These reactive elements find place in many electrical application for special equipment like electric furnaces , test bench etc. and also in the electric networks , where a compensation for capacitive elements is needed; in this case Shunt Reactors are necessary. • Oil immersed and cast resin design Single-phase or three-phase with fixed or adjustable power Power till 5 MVAR Opearating voltage till 36 kV Step regulating glass furnaces Transformers & Melting furnaces Transformers These transformers are especially designed to supply electrical power to many kind of furnaces; they are equipped by several secondary sockets to make adjustable the supplying of power to the furnace. With these regulating transformers , it’s possible to adjust the step level of power under voltage, but with no current flow, permitting to keep always "on" the medium voltage circuit breaker, and avoiding a premature wear of the same. We can manufacture also transformers to supply electrical power for medium frequency furnaces. Operating power till 10 MVA Operating voltage till 36 kV Operating current till 5000 A NEWTON TRASFORMATORI S.p.A Sede Legale, Amministrativa e Stabilimenti : Via dei Gelsi, 15 - Località Pian dei Peschi - 53036 POGGIBONSI (SI) - Tel.+39.0577.979681 r.a. - Fax +39.0577.979678 Cod. Fisc. e P. IVA 00898060520 capitale sociale 2.000.000,00 i.v. e-mail: [email protected] www.newtontrasformatori.it In supplying electrical power to furnaces , step-less regulating transformers, may be needed, as below described. • Step-less regulating Transformers ( for glass melting furnaces or their use ) The step-less regulating transformers are suitable to regulate the output voltage rate with continuity. They are executed with variable shielding , it means without any internal element of contact, such as rollers, brushes or similar, with low thermic constant and with high wear. It is possible to regulate any value of voltage of output , and whatever value of current. Single-phase or three-phase version with common or separate adjusting for the output voltage rate, can be supplied. • Nominal available power till 5000 kVA Input voltage till 36 kV Output voltage ; any minimum or maximum value, in the range of 0 till 36 kV. Maximum output current rate : till 5000 A High voltage insulating test Transformers Routinely used in laboratories for test to be performed on electrical items such as cables, insulators, transformers, components etc.. Oil immersed version , with metal tank or with insulating tank , according required values of voltage and power. Secondary voltage till 750.000 Volt Partial discharges free execution Nominal available power till 5000 kVA • Tailor made Transformers for special applications Newton Trasformatori will be pleased to analyze , design and manufacture any kind of transformer, according tailored solution proposed by the customer. NEWTON TRASFORMATORI S.p.A Sede Legale, Amministrativa e Stabilimenti : Via dei Gelsi, 15 - Località Pian dei Peschi - 53036 POGGIBONSI (SI) - Tel.+39.0577.979681 r.a. - Fax +39.0577.979678 Cod. Fisc. e P. IVA 00898060520 capitale sociale 2.000.000,00 i.v. e-mail: [email protected] www.newtontrasformatori.it