* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download G80052-W0010-J913 PREL 53_545.13 CPC-13 Relay
Opto-isolator wikipedia , lookup
Distributed control system wikipedia , lookup
Portable appliance testing wikipedia , lookup
Control system wikipedia , lookup
Resilient control systems wikipedia , lookup
Stray voltage wikipedia , lookup
Electrician wikipedia , lookup
Fuse (electrical) wikipedia , lookup
Loudspeaker enclosure wikipedia , lookup
Electromagnetic compatibility wikipedia , lookup
Ground loop (electricity) wikipedia , lookup
Electronic engineering wikipedia , lookup
Alternating current wikipedia , lookup
Electrical substation wikipedia , lookup
Transmission tower wikipedia , lookup
Surface-mount technology wikipedia , lookup
Printed circuit board wikipedia , lookup
Mains electricity wikipedia , lookup
Flexible electronics wikipedia , lookup
Surge protector wikipedia , lookup
Integrated circuit wikipedia , lookup
Overhead line wikipedia , lookup
Telecommunications engineering wikipedia , lookup
Ground (electricity) wikipedia , lookup
Earthing system wikipedia , lookup
Aluminum building wiring wikipedia , lookup
National Electrical Code wikipedia , lookup
RELAY / PLC MANUFACTURING CONTROL CHECKLIST (Refer to DQD 207) Company Name: _______________________ Supplier Name: _Siemens n.v.; Belgium____ Project No: _____________________ _G80052-W0010-L001___ Control Panel Purpose/Application:_Motor Starter for "Air compessors" of Atlas Copco nv _________ This Checklist is for Panels with a maximum rating of 30 A (above 30 A use CPC-1) Required Electrical Nameplate Ratings Input Circuits cct. 1 Volts Amp Hz Ph See: Technical Construction File=G80052-W0010-L001 Section B6: Equipment overview Section C11: Partlist cct. 2 cct. 3 Output Circuits Volts cct. 1 See: Technical Construction File=G80052-W0010-L001 Section A1: Technical Specification Electrical Circuit Section A2: Electrical Data of Compressor and Loads cct 2 cct. 3 cct. 4 cct. 5 Enclosure type required (1, 2, 3, 3R, 4X, 5, 12,13) Amp VA Hz Ph cct. 6 The following Controllers require an additional checklist along with the Basic Checklist: Please indicate with () if applicable. Traffic cCSAus Heating Oil/Gas Burning Panels with barriers for IS circuits Enclosure (type 1) The following Equipment does not fall under this Programme . Please contact CSA for more Information. Elevator - Line isolator monitors - Hazardous location - Signal type ground fault devices - Hydro-massage Marine - Purged Equip. for use in Hazardous Loc, see also Checklist CPC-1 Special Requirements: _____________________________________________________________________________________ _____________________________________________________________________________________ Is the rating and scope of the Control Panel within the scope of CSA Certification? 1 NO Yes Conformance Markings 5.1 YES N/A Yes No Comments Nameplate Metal nameplate riveted to enclosure. Or ToDo by AC OFA CSA approved adhesive nameplate (as documented in the CSA report ) is used. 5.1 5.3 5.4 5.8 The nameplate specifies the following information: - Manufacturer's name, trademark or CSA file no. - Complete Electrical Rating: Input -Volts: Current; No. of Phases/DC; Frequency - for each circuit. & Output - Volts; Current - for each circuit. - Catalogue number or equivalent - CSA Monogram or ToDo by AC OFA See also: TCF= G80052-W0010-L001 Section B6: Equipment overview - The CSA Monogram with the CSAus indicator adjacent to the CSA Mark if CPC-5 is completed. NA Section C11: Partlist CSA Only - The CSA Monogram with the “cCSAus” indicator adjacent to the CSA Mark if CPC-8 is completed NA CSA Only 5.1 Nameplates correspond with drawings. Y 5.1 Mfr's instruction sheets have been installed in cabinet pocket. DQD 545.13 (Form CPC-13) 2004-06-30 ToDo by AC OFA Page 1 of 6 81953762 RELAY / PLC MANUFACTURING CONTROL CHECKLIST (Refer to DQD 207) Conformance Markings 2 N/A Yes No Comments Other Markings 5.17 The control circuit fuse replacement information appears adjacent to the fuseholder. Y 5.48 The branch circuit fuse replacement information appears adjacent to the fuseholder. Y Main Fuse to be installed by EndCustomer, Info ToDo by AC OFA Interrupting switching device markings are re-applied if their markings are obstructed by the addition of an interlocking device. C22.2 No. 0.4 All ground lugs are labelled. Y 5.18 All terminals are labelled . Y 3 5.16 5.43 5.42 4.2.5.11 Cautions and Warnings ( When Applicable ) "WARNING: MORE THAN ONE LIVE CIRCUIT. SEE DIAGRAM" and where required - ToDo by AC OFA "AVERTISSEMENT: CET EQUIPEMENT RENFERME PLUSIEURS CIRCUITS SOUS TENSION. VOIR LE SCHEMA". ToDo by AC OFA "WARNING: TWIST WIRES TOGETHER BEFORE INSERTING IN TERMINAL" and where required - NA "AVERTISSEMENT: ENROULEZ LES FILS ENSEMBLE AVANT DE LES INTRODUIRE PANS LA BOURNE". NA "WARNING: WHEN MOUNTING ON OR OVER A COMBUSTIBLE SURFACE, A FLOOR PLATE OF AT LEAST 1.43 mm GALVANIZED OR 1.6 mm UNCOATED STEEL EXTENDED AT LEAST 150 mm BEYOND THE EQUIPMENT ON ALL SIDES MUST BE INSTALLED." and where required - Note: This marking need not be permanent. NA "AVERTISSEMENT:LORSQUE L'APPAREIL EST INSTALLE SUR OU AUDEUSS D'UNE SURFACE COMBUSTIBLE, ON DOIT PREVOIR UNE PLAQUE D'ACIER GALVANISE D'AU MOINS 1.43mm OU UNE PLAQUE SANS REVETEMENT DE 1.6mm SE PROLONGEANT SUR AU MOINS 150mm TOUT AUTOUR DE L'APPAREIL". NA DQD 545.13 (Form CPC-13) 2004-06-30 Page 2 of 6 81953762 RELAY / PLC MANUFACTURING CONTROL CHECKLIST (Refer to DQD 207) 4 4.1.1 or 4.2 Enclosure Requirements - Is the enclosure a purchased CSA certified enclosure ; or the enclosure construction has been approved and documented in a CSA Certification report. N N See CPC-14 If not, contact your CSA tech. representative and complete Checklist CPC-14. 4.1.2 - Components such as pilot lights, push buttons, etc. are certified for the correct environment. i.e. Type 4/4x etc. Y S2: Emergency stop E1: Mk IV/V 4.2.2.3 - Are additional barriers required to protect against live parts? Y 1X0: Main Supply 4.2, 4.2.5 - Modification of enclosure complies with all the requirements for non certified enclosures as well as allowable opening . 4.2.2.1 - Doors and covers are lockable or require the use of a tool to enter 4.3.3 - No plastic covers are provided, except that metres may be mounted on the doors or walls. 5 4.2.5 - Vents are limited to less than 12.7mm (1/2 in.), or comply with CSA Std. C22.2 No. 14-95, cl. 4.2.5.1 b. 6 4.16.1.4 & .5 4.16.1.4 & .5 NA Allowed openings: a. 4.16.1 Y Y Vents must leave sufficient metal to retain the strength of the enclosure (if at least 1mm). See CSA Std. C22.2 No. 14-95, cl. 4.2.5.2 for details. - Mounting Holes are 3.2mm dia. max. unless they can be mounted in such a manner as to cover the opening. See CSA Std. C22.2 No. 14-95, c l. 4.2.5.2 for details. - Conduit openings when provided comply with Table 1 of C22.2 No. 0-M91. Max dimension: cUR filters Y NA Trade sizes: Diameters: metric sizes used, sizes in table 1 are recommendations Grounding and Bonding One ground termination means is provided for each incoming power circuit and one for each outgoing power circuit. OR Grounding Terminal kits are provided. Y Minimum of one bonding conductor is provided for control circuits. Y Enclosure doors are bonded to the enclosure. Y The size of the grounding conductors are as per Table 31 of CSA Std.C22.2 No.14-95, and the size and number of conductors per terminal complies with table 30 of CSA Std. C22.2 No. 14-95. Y No. 14 AWG/2,5mm² copper or No. 12 AWG aluminium for control conductors and auxiliary devices. Y See also: TCF= G80052-W0010-L001 Section C12: Wiring Bonding is provided as required by Section 4.16 of C22.2 No 14-95, C22.2 No 0.4-M1982 and the requirements of PART 1 of the Canadian Electrical Code. 7 Field Wiring Terminations 4.14.1.4 Line and load terminals must be CSA certified lugs. Y ToDo by AC OFA 4.14.1.4.3 The field wire is properly sized. (use 60 C copper (or aluminium) wire of table 34) Y ToDo by AC OFA 5.2 If aluminium wire is used terminal must be marked for use with aluminium. DQD 545.13 (Form CPC-13) 2004-06-30 Page 3 of 6 81953762 RELAY / PLC MANUFACTURING CONTROL CHECKLIST (Refer to DQD 207) 8 Internal Power Wiring Wiring is CSA Certified Type: ________; rated: ______ V; ______ C Y standard CSA TEW (according to C22.2 No. 127) Wiring in cULus traceability program CSA (TEW): U: 600 V; CSA (TEW): -40°C to +105°C 4.1.1 CSA certified. (CSA serialized tags appear on the wire spool) Y 4.13.3 Rated for the highest voltage or physically segregated from circuits of different voltages. Y 4.13.1 Rated 90C or greater. Y 4.13.1 Sized as per table 3 of CSA Std. C22.2 No. 14-95. Cct. Rated:___A; Wire Size:____ AWG Cct. Rated:___A; Wire Size:____ AWG Cct. Rated:___A; Wire Size:____ AWG Cct. Rated:___A; Wire Size:____ AWG Cct. Rated:___A; Wire Size:____ AWG See: TCF= G80052-W0010-L001 Cct. Rated:___A; Wire Size:____ AWG Cct. Rated:___A; Wire Size:____ AWG Cct. Rated:___A; Wire Size:____ AWG Cct. Rated:___A; Wire Size:____ AWG Cct. Rated:___A; Wire Size:____ AWG Section C12: Wiring 4.13.2 Conductors not smaller than 24 AWG. Y 4.13.5 Wiring is not in contact with bare live parts. Y 4.13.6 Bare conductors are supported or covered by suitable insulating sleeving or tubing. C22.2 No. 0.4 4.13.4 Ground conductors used are green colour. Wires are supported so as not to contact moving parts or rest on sharp edges. Y 4.13.4 Wires are flexible, with extra length and protection when connecting to door mounted equipment. Y 9 4.1.1 Green/Yellow Bare Copper rod Components & Installation Components are CSA certified and have a visible CSA mark or accepted noncertified components as listed in "Attachment 2". CSA-File @ AC OFA Indicating instruments such as volt and ammeter , solid-state devices (SCR's diodes, etc.), which are not CSA Certified, appear in "Attachment 2" of the CSA Report. CSA-File @ AC OFA Special shielded low voltage wires, thermocouple leads, etc., which are not CSA NA Certified are Acceptable in Class II limited energy circuits provided they are installed in accordance with requirements of the CE Code, Part I. 4.2.2.3 Wires are installed properly. ( i.e. insulation not under screws, No. strands of wire are loose around the connection, all connections are tight, etc...) Y Wiring corresponds with elementary diagrams. Y Device part numbers correspond with bill of material. Y Phasing is proper and in accordance with the drawing. Y All items are securely fastened. Y Hinged doors and internal barriers are provided to prevent contact with bare live parts during normal operation. Y The electrical ratings of the components are suitable for the application. Examples of special purpose electrical ratings are indicated below: Y General Purpose AC General Purpose DC Resistive Heating Duty AC/DC Incandescent Lighting Duty Electric Discharge Lamp (Ballast) Duty AC Pilot Duty Rating (HD or A600) - 720VA AC Pilot Duty rating (SD Duty or B600) - 360VA DC Pilot Duty (Heavy Duty or N600) - 275VA DC Pilot Duty (Standard Duty or P600) - 138VA DQD 545.13 (Form CPC-13) 2004-06-30 Page 4 of 6 81953762 RELAY / PLC MANUFACTURING CONTROL CHECKLIST (Refer to DQD 207) 10 4.11.1.1 Protection Branch Circuit Protection complies with CSA Std.C22.1-94, Section 14, and 26. Main Fuse to be installed by EndCustomer, Info ToDo by AC OFA See also: TCF= G80052-W0010-L001 NOTE: 1. Branch circuits must be protected against both short circuit and overload by CSA Certified fuses, or thermal-magnetic circuit breakers. Section B6: Equipment overview 28-202 The power supply is protected with the fuse specified on its nameplate or its installation instructions. Y For high short circuit capacity ratings, the overcurrent protective device is in accordance with the markings of 5.45. Y Control Transformer protection complies with CSA Std.C22.1 cl. 26-256 except: Y 1) 2) Primary protection 125% (No. primary protection is required if the secondary protection is 125% and the feeder protection is 300%) For NRTL/C, refer to certification report. See also: TCF= G80052-W0010-L001 Section B6: Equipment overview Section C11: Partlist Record: Transformer Protection Provided: Transformer rating: ____ VA, I/P ____Amp., O/P____Amp. Pri. protection______ Amp. Sec. protection ______Amp. 11 TESTS - Dielectric Withstand Is the calibration date on the dielectric strength tester still effective? Record: Test voltages:_____________ Duration:_______ Sec. ToDo by AC OFA Note: Prim: (1000+2x600)=2,2kV Sec: (1000+2x115)=1,23kV The dielectric withstand is to be performed on the motor power wiring and the control wiring. Be sure to remove the ground from the transformer before starting the test and that the test panel ground is connected to the control panel ground. Also ensure that all electronic devices are removed from their sockets, high pot test may damage these devices. (This includes all PLC's, cards, communication devices etc.). Use the nameplate on the test panel for selection of proper test voltage. Were defective component(s) found? Were defective component(s) replaced and retested in the panel? DQD 545.13 (Form CPC-13) 2004-06-30 Page 5 of 6 81953762 RELAY / PLC MANUFACTURING CONTROL CHECKLIST (Refer to DQD 207) Drawing List: See: TCF= G80052-W0010-L001 Assembly ____________ ____________ ____________ rev _____________ _____________ _____________ Schematic ____________ ____________ ____________ rev ______________ ______________ ______________ Wiring ____________ ____________ ____________ rev _____________ _____________ _____________ Other ____________ ____________ ____________ rev ______________ ______________ ______________ Engineering Dept Representative:________________________________________________________________ Manufactured/Wired by:____ ____________________________________________________________________ Tested By:____________________________________________________________________________________ Supplier Engineering Dept Representative:____ Verhavert Jan; SWE RC-BE I S GMF ____________________________ Manufactured/Wired by:____ Siemens nv, Belgium _______________________________________________ THIS CONTROL PANEL COMPLIES WITH THE APPLICABLE CSA REQUIREMENTS APPROVED BY: ________________________________ SIGNATURE: ___________________________________ DQD 545.13 (Form CPC-13) 2004-06-30 Page 6 of 6 81953762