Survey
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Equipment Specifications for VISUAL FIELD ANALYSER UNSPSC Code: ECRI Code: 1 Description of Function Sl Name 1.1 During a routine eye exam this is used to determine through visual field testing the full horizontal and vertical range of what the patient is able to see peripherally. Technical Bidders Specs Deviation quoted if any by bidder 2 Operational Requirements Sl Name 2.1 Should be a computerized visual field analyzer. This should systematically plot the field of vision using threshold testing, and permit the determination of retinal sensitivity in any given location. 2.2 The system should meet all the numerical values given in the technical specifications within a tolerance of +/- 10 %. Technical Bidders Specs Deviation quoted if any by bidder 3 Technical Specifications Sl Name 3.1 High quality Goldman standard automated perimeter with bowl size 30cm 3.2 Maximum intensity 10,000Asb, Bowl illumination 31.5Asb 3.3 Floppy drive, internal hard disk drive with Magneto Optical Disk (MOD) drive 3.4 Stimulation duration 200ms, wavelenth Broad band visible light 3.5 Stimulus/background colour White on White, Blue on yellow (SWAP) 3.6 Maximum temporal range 90Deg. Suitable for central 30 as well as full field testing 3.7 Central field test patterns 30-2,24-2, 10-2, Macula 3.8 Peripheral field test pattern 60-4, Nasal Step 3.9 Threshold test strategies full threshold, Fast Pac, SITA or equivalent Technical Bidders Specs Deviation quoted if any by bidder 3.10 Glaucoma progression analysis and Serial Analysis for patient follow up 3.11 Screening field test P-60, FF-240, Nasal Step for periphery. 3.12 Screening test strategies Two zone, Three Zone and Quantify Defects 3.13 Kinetic Testing, Custom Test, Automatic Pupil measurement 3.14 Stimulus Size I-V as per Goldman standards 3.15 Glaucoma hemi field test, Hail -Krakau blind spot monitor 3.16 Video eye monitoring, trial Lens Holder, Gaze tracking System 3.17 Head tracking, Vertex Monitoring, Touch screen on CRT, Keyboard 3.18 Motorized chinrest, Original Manufacturer Motorized table with Laser Jet Printer 4 System Configuration Accessories, spares and consumables Sl Name 4.1 System as specified Technical Bidders Specs Deviation quoted if any by bidder 5 Environmental factors Sl Name 5.1 The unit shall be capable of being stored continuously in ambient temperature of 0 -50deg C and relative humidity of 15-90% 5.2 The unit shall be capable of operating in ambient temperature of 20-30 deg C and relative humidity of less than 70% 5.3 Shall meet IEC-60601-1-2 :2001(Or Equivalent BIS) General Requirements of Safety for Electromagnetic Compatibility.or should comply with 89/366/EEC; EMC-directive. Technical Bidders Specs Deviation quoted if any by bidder 6 Power Supply Sl Name 6.1 Power input to be 220-240 VAC, 50Hz fitted with Indian plug 6.2 Resettable overcurrent breaker shall be fitted for protection 6.3 Suitable UPS with maintenance free batteries for minimum onehour back-up should be supplied with the system. Technical Bidders Specs Deviation quoted if any by bidder 6.4 Voltage corrector/stabilizer of appropriate ratings meeting ISI Specifications.( Input 160-260 V and output 220-240 V and 50 Hz) 7 Standards, Safety and Training Sl Name 7.1 Manufactures/Supplier should have ISO certificate to Quality Standard. 7.2 Should be FDA, CE, UL or BIS approved product 7.3 Comprehensive training for lab staff and support services till familiarity with the system. 7.4 Electrical safety conforms to standards for electrical safety IEC 60601-1 (OR EQUIVALENT international/national standard)General requirement for Electrical safety of Medical Equipment. Technical Bidders Specs Deviation quoted if any by bidder 8 Documentation Sl Name 8.1 User/Technical/Maintenance manuals to be supplied in English. 8.2 Certificate of calibration and inspection. 8.3 List of important spare parts and accessories with their part number and costing. 8.4 Log book with instructions for daily, weekly, monthly and quarterly maintenance checklist. The job descriptin of the hospital technician and company service engineer should be clearly spelt out. 8.5 Compliance Report to be submitted in a tabulated and point wise manner clearly mentioning the page/para number of original catalogue/data sheet.Any point ,if not substantiated with authenticated catalogue/manual, will not be considered. 8.6 List of Equipments available for providing calibration and routine maintenance support as per manufacturer documentation in service / technical manual. Technical Bidders Specs Deviation quoted if any by bidder