* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Voltage leval improment by using Static VAR compensator (SVC)
Spark-gap transmitter wikipedia , lookup
Power over Ethernet wikipedia , lookup
Wireless power transfer wikipedia , lookup
Ground (electricity) wikipedia , lookup
Audio power wikipedia , lookup
Mercury-arc valve wikipedia , lookup
Electrification wikipedia , lookup
Electrical ballast wikipedia , lookup
Power factor wikipedia , lookup
Electric power system wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Power inverter wikipedia , lookup
Electric power transmission wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Current source wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Opto-isolator wikipedia , lookup
Three-phase electric power wikipedia , lookup
Power MOSFET wikipedia , lookup
Amtrak's 25 Hz traction power system wikipedia , lookup
Voltage regulator wikipedia , lookup
Electrical substation wikipedia , lookup
Surge protector wikipedia , lookup
Power engineering wikipedia , lookup
Stray voltage wikipedia , lookup
Power electronics wikipedia , lookup
Buck converter wikipedia , lookup
History of electric power transmission wikipedia , lookup
Voltage optimisation wikipedia , lookup
Switched-mode power supply wikipedia , lookup
International Journal of Current Trends in Engineering & Research (IJCTER) e-ISSN 2455–1392 Volume 2 Issue 4, April 2016 pp. 342 - 348 Scientific Journal Impact Factor : 3.468 http://www.ijcter.com Voltage Leval Improment by Using Static VAR Compensator (SVC) Wagh Vijay R.1 , Jadhav Sunil A.2 , Dange Sagar A.3 1,2,3 Electrical Engineering , S.B.Patil C.O.E. Abstract—This paper will discuss how static Var compensator successfully been applied to control transmission system. The voltage level of the system changes when there is a change in load and the drop in load voltage lead to demand for the reactive power. Static VAR Compensation under FACTS uses TCR (Thyristor Control Rector) based on shunt compensation duly controlled from a programmed microcontroller. Shunt capacitive compensation - This method is used improve the power factor. Whenever an inductive load connected to the transmission line, power factor lags because of lagging load current. To compensate, a shunt capacitor is connected which draws current leading the source voltage. The net result is improvement in power factor. The time lag between the zero voltage pulse and zero current pulse duly generated by suitable operational amplifier circuits in comparator mode are fed to two interrupt pins of the microcontroller where the program takes over to actuate appropriate number of opto-isolators duly interfaced to back to back SCR at its output for bringing shunt capacitors into the load circuit to get the power factor till it reaches 0.95. The microcontroller used in the project is of 8051 family which is of 8 bit. The power supply consists of a step down transformer 230/12V, which steps down the voltage to 12V AC. This is converted to DC using a Bridge rectifier. The ripples are removed using a capacitive filter and it is then regulated to +5V using a voltage regulator 7805 which is required for the operation of the microcontroller and other components Keywords—FC-TCR type SVC, SVC control, dynamic control of reactive power, FACTS Controllers, Microcontroller based control of Reactive power, TCR control, Single I. INTRODUCTION There is a continuous rise in demand of electrical power. To meet this rise, the growth in generation is stability, voltage collapse and grid failure. To provide stable, secure and quality power supply to end users and to utilize available transfer capacities in better way, Flexible AC transmission systems (FACTS) controllers are used to enhance power system stability along with their main application of power flow controlessential, which is not always possible due to various limitations like environmental, financial, resources, land, etc. Expansion of transmission network is always not easy. Due to these problems, the entire power system is operated at its highest capacity which may generate problems of of stability, voltage collapse and grid failure. To provide stable, secure and quality power supply to end users and to utilize available transfer capacities in better way, Flexible AC transmission systems (FACTS) controllers are used to enhance power system stability along with their main application of power flow control In this paper, the design and fabrication of 1- phase fixed capacitor-thyristor controlled reactor (FC- TCR) type SVC based on microcontroller have been developed in the laboratory for Bulp Load Test System.The Static Var Compensator (SVC) is an early generation of FACTS Controllers and a proven technology for voltage stability and power factor correction. The SVC is composed of a fixed capacitor (FC) and a thyristor controlled reactor TCR. This paper deals with the Design, Fabrication and Testing of Microcontroller based SVC along with Automatic Control circuit Hardware. The laboratory setup of the Bulp Load test system with and with out SVC Automatic control circuit have been Developed. SVC is comprised of a thyristor controlled reactor in @IJCTER-2016, All rights Reserved 342 International Journal of Current Trends in Engineering & Research (IJCTER) Volume 02, Issue 04; April – 2016 [Online ISSN 2455–1392] parallel with capacitor. The test results to inject or absorb VArs into the system for maintaining constant voltage profile have been presented in this paper. This fine tuning is accomplished by varying the firing delay angle (α) of the reactor, thus modifying the TCR VArs absorbed. if α = 0 is defined as the zero crossing of the applied voltage, then firing angles will be in the range of (π / 2) ≤ α ≤ π for each half-cycle II. STATIC VAR COMPENSATOR A) Configuration of SVC :SVC provides an excellent source of rapidly controllable reactive shunt compensation for dynamic voltage control through its utilization of high-speed thyristor switching/controlled devices . A SVC is typically made up of coupling transformer, thyristor valves, reactors, capacitance (often tuned for harmonic filtering). b) Advantages of SVC:The main advantage of SVCs over simple mechanically switched compensation schemes is their near-instantaneous response to change in the system voltage. For this reason they are often operated at close to their zero-point in order to maximize the reactive power correction . They are in general cheaper, higher-capacity, faster, and more reliable than dynamic compensation schemes such as synchronous compensators (condensers). In a word: 1) 2) 3) 4) 5) 6) Improved system steady-state stability. Improved system transient stability. Better load division on parallel circuits. Reduced voltage drops in load areas during severe disturbances. Reduced transmission losses. Better adjustment of line loading. In its simplest form, SVC is used as Fixed Capacitor-Thyristor Controlled Reactor (FC-TCR) configuration as shown in Fig. 1. The TCR branch provides continuously controllable reactive power only in the lagging power-factor region. To extend the controllable range to the leading power-factor region, a fixed-capacitor bank is connected in shunt with the TCR. The TCR VAr is rated larger than the fixed capacitor to compensate the capacitive VAr and provide net inductivereactive power should a lagging power-factor operation be desired Fig.1: Configuration of FC-TCR @IJCTER-2016, All rights Reserved 343 International Journal of Current Trends in Engineering & Research (IJCTER) Volume 02, Issue 04; April – 2016 [Online ISSN 2455–1392] The fixed-capacitor banks, generally connected in a star configuration, are split into 3-phase group. Each capacitor consists of a small tuning inductor which is connected in series and tunes the branch to work as a filter for a specific harmonic order. III. HARDWARE IMPLEMENTATION Here the hardware setup is done on medium transmission line model and under variable RL load condition firing angle is set to change the requirement of reactive power injection into the system. The firing angle is generated using microcontroller 89C51 (8051). The pulses are generated based on Zero crossing detector circuit input of ZCD is given to controller based on ZCD output microcontroller generates pulses and that is given to antiparallel connected thyristor with isolation using coupler ICs. In actual single pulse is generated that is inverted and given to second thyristor of same leg with assurance of avoiding short circuit of the thyristor pair leg. Fig.2: Project Block Diagram Experimental setup of the hardware is shown in Fig. is very similar to system with Microcontroller based control of Reactive power, TCR and FC control, Single phase. Load in laboratory setup is chosen as RL load and value of Fixed Capacitor is 2.5mf and inductive load of 40watt, 230V AC ,0.4A,Sending end voltage is set to 230Volt and receiving end voltage is measured for various load condition Voltage regulation is provided by means of a closed-loop controller. SVC control circuit consists following blocks, such as step down/up transformer, rectifier bridge circuit, active power filter, voltage. @IJCTER-2016, All rights Reserved 344 International Journal of Current Trends in Engineering & Research (IJCTER) Volume 02, Issue 04; April – 2016 [Online ISSN 2455–1392] Hardware Circuit Implementation of Automatic Control of Static Var Compensator (SVC) using Micro Controller regulator, gate pulse generating unit (i.e.firing unit)The gating or ‗turn on‘ signal to each thyristor isdelayed by α, the firing or conduction angle, from the zero crossing of the source voltage Fig.3:Hardware implementation of TCR After implementing hardware circuit with full wave bridge rectifier and zero crossing detector using dual operational amplifier output signals are obtained as shown in figure 3 at each zero crossing pulses are generated from operational amplifier the same pulses are given to microcontroller unit and then processed for delay operation for firing of thyristor Ultimately with increase in firing angle current decreases. So the system reactive power can be varied by varying the firing angle α. Fig.4:Comparison of rectifier output with ZCD pulses IV. PERFORMANCE SVC CONTROLLER An SVC is a controlled shunt susceptance (B) as defined by control settings that injects reactive power (Q) into the system based on the square of its terminal voltage. illustrates a TCR SVC, including the operational concept. The control objective of the SVC is to maintain a desired voltage at the high-voltage bus. In the steady-state, the SVC will provide some steady-state control of the voltage to maintain it the high-voltage bus at a pre-defined level. If the high-voltage bus @IJCTER-2016, All rights Reserved 345 International Journal of Current Trends in Engineering & Research (IJCTER) Volume 02, Issue 04; April – 2016 [Online ISSN 2455–1392] begins to fall below its set point range, the SVC will inject reactive power (Qnet) Into thereby increasing the bus voltage back to its net desired voltage level. If bus voltage increases, the SVC will inject less (or TCR will absorb more) reactive power, and the result will be to achieve the desired bus voltage. +Qcap is a fixed capacitance value, therefore the magnitude of reactive power injected into the system, Qnet, is controlled by the magnitude of –Qind reactive power absorbed by the TCR Fig 5.Controlling scheme for SVC branch V. OPERATION OF TCR The fundamental operation of the thyristor valve that controls the TCR is described here. The thyristor is self commutates at every current zero, therefore the current through the reactor is achieved by gating or firing the thyristor at a desired conduction or firing angle with respect to the voltage waveform. The gating or ‗turn on‘ signal to each thyristor is delayed by α, the firing or conduction angle, from the zero crossing of the source voltage as illustrated in . As current lags the voltage across the reactor by 90°, so a firing angle of ninety degrees results in maximum, that is, continuous reactor current. For a firing angle of 180°, the reactor current will be zero. As the thyristor firing angle is increased from 90 towards 180 degrees, the current in the reactor is reduced. Therefore, the firing angle can be in the range of 90° ≤ α ≤ 180° to vary the TCR current from zero to its maximum by phase angle control of the thyristors. The reactor is connected in series with two antiparallel thyristors. The conduction interval is reduced from maximum to zero. In terms of suseptance, ISVC = j BSVCV Where: BSVC = BTCR + B c Bsvc = BL((π-2α-sinα)/π) + B c Where, B c = 1/ Xc BL = 1/XL In terms of reactance, X SVC =XCXTCR/XC+XTCR @IJCTER-2016, All rights Reserved 346 International Journal of Current Trends in Engineering & Research (IJCTER) Volume 02, Issue 04; April – 2016 [Online ISSN 2455–1392] Where, X TCR = π X L /σ- Sinσ X SVC = πXCX L / (XC (σ- Sinσ) - π X L) Where, σ = 2(π- α) XSVC= πXCX L/ XC [(2(π -α)- Sin2σ)- π X L] X SVC =VBus2/ Q SVC QSVC = VBus2 (XC [2π- σ+ Sin2σ] - π X L)/ πXCX L Generally, by changing the firing angle ‗α‘the fundamental reactance X L of the reactor is changed. XL =V/ I FL1 VI. RESULT ANALYSIS So the system reactive power can be varied by varying the firing angle α. Readings are taken for various load condition tabulated and table 1 and table 2 withour SVC and with SVC(variable firing angle α). Table 1: Voltage Variation without SVC Terminal voltage S.No Load current Power Factor Time(ms) Io(Amps) VL (V) Output Power (Watts) 1 195 1.56 0.985 0 299.67 2 197 1.53 0.95 0-1 286.33 3 198 1.47 0.8 1-2 232.84 4 197 1.51 0.929 1.246 276.34 5 197 1.50 0.917 1.253 270.97 Table 2: Voltage Variation with SVC S.No Terminal voltage Load current Power Factor Time(ms) Output Power (Watts) VL (V) Io(Amps) 1 192 1.77 1 0 339.84 2 193 1.67 1 0 322.31 3 195 1.61 1 0 331.95 4 197 1.55 1 0 305.35 5 198 1.53 1 0 302.94 @IJCTER-2016, All rights Reserved 347 International Journal of Current Trends in Engineering & Research (IJCTER) Volume 02, Issue 04; April – 2016 [Online ISSN 2455–1392] VII. CONCLUSION Simulation results are verified using hardware implementation and it is found that FC-TCR is effective compensation technique compare to mechanical operated or other dynamic power flow controllers. Also it is observed that in closed loop system the performance of system improved as well response time of system is very fast Dynamic performance and voltage control analysis will continue to be a very important process to identify system problems and demonstrate the effectiveness of possible solution. REFERENCES [1] [2] [3] [4] [5] [6] K.R. Padiyar, ―FACTS controllers in power transmission and distribution,‖New Age Int. Publisher, 2007 Ghanshyam Vishwakarma, Nitin Saxena ―Enhancement of Voltage Profile using Fixed Capacitor Thyristor Controlled Reactor (FC-TCR)‖International Journal of Electrical, Electronics and computer Engineering 18-22(June 2013) T. Vijaykumar, A.Nirmalkumar ―Experimental Results of Microcontroller Based FC-TSR-TCR Systems‖ International Journal of Electrical and Electronics System Research vol 3 June 2010 Dr. SA Khaparde, Mr. S.M. Brahma, "Flexible AC Transmission System (FACTS): An Overview", Transmission and Distribution in 2000 Technical Conferences February 1996. pp. 1-5 N.G Hingorani & Laszlo Gyugyi, ―Understanding FACTS: concepts and technology of flexible AC transmission System‖, IEEE Press, R.M. Mathur and R.K. Varma, Thyristor-Based FACTS Controllers for Electrical Transmission Systems, IEEE Press and Wiley Interscience, New York, USA, Feb. 2002. @IJCTER-2016, All rights Reserved 348