* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Document
Thermal runaway wikipedia , lookup
Mercury-arc valve wikipedia , lookup
Power inverter wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Electrical substation wikipedia , lookup
Spark-gap transmitter wikipedia , lookup
Stepper motor wikipedia , lookup
Three-phase electric power wikipedia , lookup
History of electric power transmission wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Distribution management system wikipedia , lookup
Electrical ballast wikipedia , lookup
Power electronics wikipedia , lookup
Opto-isolator wikipedia , lookup
Current source wikipedia , lookup
Voltage regulator wikipedia , lookup
Power MOSFET wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Surge protector wikipedia , lookup
Current mirror wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Stray voltage wikipedia , lookup
Voltage optimisation wikipedia , lookup
Buck converter wikipedia , lookup
The main technical parameters of the electrolytic capacitor 1 equivalent series resistance ESR The level of the ESR, and the capacity of the capacitor, the voltage, frequency and temperature ... are related, ESR requirements better. When the rated voltage is fixed, the capacity, the greater the lower the ESR. When the capacity is fixed, choosing varieties of high rated voltage can reduce the ESR. ESR at high frequency, high frequency low ESR, high temperatures also cause increased ESR. Equivalent series resistance ESR many brands can be found from the specification. (2) Leakage Current One can understand that leak! Electrolytic capacitor leakage exists, and this is the physical structure of the decision. Needless to say, the leakage current is of course the smaller the better. The higher the capacitor, the greater leakage current; reduce operating voltage can reduce the leakage current. In turn, choose a higher-pressure varieties will help reduce leakage current. Combination of the above two parameters, under the same conditions of high pressure varieties selected priority is indeed a good way to an easy feasible; reduce resistance, reduce the leakage current, reduce losses and increase life expectancy. A lot of really good, only the price will be higher. There is a saying, both electrolytic capacitors work well below the rated working voltage, because it is not effective enough to sustain electrode with the electrolyte between the depolarization effect, will result in the polarization of the electrolytic capacitor ripple current is reduced, increasing Big ESR, thus premature aging. But the premise of this argument is "far below the rated working voltage", some long-term practical experience integrated view, select the rated voltage of the nominal value 2/3 of the normal operating voltage, it is more reasonable to * a. Amateur circumstances can electrolytic capacitor leakage current general estimate. The same capacity electrolytic capacitor is charged according to the rated withstand voltage, place some time before detecting the voltage drop across the capacitor extent. Voltage drop, the less the smaller the leakage current. 3. The nominal parameters Capacitor case is the value listed on. * Electrostatic capacity, expressed by UF. Not much to say. * Operating voltage (working voltage) referred WV, safety should be the nominal value, ie the application circuit must not exceed this nominal voltage. * Most common temperature of 85 degrees, 105 degrees. High temperature conditions (eg Pure Class A amplifier) should preferably 105 degrees nominal. Generally a high temperature coefficient is preferably other parameters to improve performance a positive help. 4 Dissipation factor dissipation factor (DF) Sometimes DF values expressed by the loss angle tan. DF value is high or low, and the temperature, capacity, voltage, frequency ...... have a relationship; when the capacity is the same, the higher the pressure the lower the value of DF. The higher the frequency the higher the DF value, the higher the temperature the higher the DF values. DF values are generally not indicated on the capacitor or specifications described above. Select a capacitor in the DIY, you can select a higher priority to pressure, such as when the operating voltage of 45V, the 50V's not very reasonable. Although the use of 50V withstand voltage from the normal work there is nothing wrong, but the lack of DF values on a number of considerations. Use 63V or 71V breakdown voltage will have better performance. Of course, no matter how high the price on uneconomical. 5 Ripple Current Irac Ripple current filter circuit for stone, it is a very important parameter. Ripple Current Irac is as high as possible. His low working frequency, the higher the frequency the greater Irac, the lower the frequency the smaller Irac. The traditional think we need at low frequencies can have a high ripple current, in order to get a good high-current discharge characteristics, so that the low-frequency more solid and full flexibility, and good driving characteristics control; actually high at high frequencies ripple current on the positive tone was also very helpful, you can make a better high-frequency extension and reduced roughness.