Electrical ballast wikipedia , lookup

Ohm's law wikipedia , lookup

History of electric power transmission wikipedia , lookup

Coilgun wikipedia , lookup

Power engineering wikipedia , lookup

Pulse-width modulation wikipedia , lookup

Power inverter wikipedia , lookup

Three-phase electric power wikipedia , lookup

Stray voltage wikipedia , lookup

Commutator (electric) wikipedia , lookup

Current source wikipedia , lookup

Rectifier wikipedia , lookup

Schmitt trigger wikipedia , lookup

Resistive opto-isolator wikipedia , lookup

Brushless DC electric motor wikipedia , lookup

Electrification wikipedia , lookup

Voltage regulator wikipedia , lookup

Electric machine wikipedia , lookup

Mains electricity wikipedia , lookup

Power electronics wikipedia , lookup

Opto-isolator wikipedia , lookup

Voltage optimisation wikipedia , lookup

Buck converter wikipedia , lookup

Electric motor wikipedia , lookup

Alternating current wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Dynamometer wikipedia , lookup

AC motor wikipedia , lookup

Induction motor wikipedia , lookup

Stepper motor wikipedia , lookup

Brushed DC electric motor wikipedia , lookup

Variable-frequency drive wikipedia , lookup

Transcript
Islamic University of Gaza
Electric Machine Lab
Faculty of Engineering
Eng. Omar A. Qarmout
Eng. Amani S. Abu Reyala
Electrical Engineering department
Experiment DIRECT CURRENT MOTORS
SEPARATELY EXITED, SHUNT AND COMPOUND CONNECTION
7
INTRODUCTION
The dc motor is the machine that converts the electric energy into mechanical energy, in other
meaning, it is considered a voltage to speed converter figure 7.1 (a, b) and a current to torque
converter figure 7.1 (c, d).
(a) DC Motor as a Voltage-to-Speed Converter
(c) DC Generator as a Torque-to-Current Converter
(b) Output Speed versus Voltage
(d) Output Torque versus Current
Figure 7.1: DC Motor
When the output current increases the output speed decreases under fixed input voltage since there is
an internal resistance n the armature
which consume part from the input voltage Figure 7.2.
& ; So when increase
decreases and the speed decreases.
(a) Simplified Equivalent Circuit of a DC Motor
(b) Speed Versus Current Characteristic of a
Separately-Excited DC Motor (Fixed Voltage)
Figure 7.2: The Effect of Increasing the Input Current on the Output Speed in the DC Motor
The magnet of the generator is electrical magnet which depends on its field current. The properties of
the DC Motor are changed with changing the field current figure 7.3.
Figure 7.3: Decreasing Current
below its Nominal Value Increases
and Decreases
There are four connecting methods for the DC Motor one needs external voltage for the magnet coil
and the other three depend on the input voltage of the motor. The relation between the output torque
and the output speed is different from one to another Figure 7.4.
Figure 7.4: Torque versus Speed Characteristics of Various DC Generators.
PART1: SEPARATELY EXITED DC MOTOR AND FIELD CURRENT EFFECTS
ƒ OBJECTIVE:
After completing this part, you will be familiar with:
‐ The relation between the input voltage and the output speed of the DC Motor.
‐ The relation between the input current and the output torque of the DC Motor.
‐ The relation between the output speed and the input current.
‐ The effects of the magnetic current on the characteristics of the DC Motor.
ƒ INTRODUCTION:
At first a separated source will be used to obtain the current in the magnetic circuit of the stator that
is the magnetic circuit is not connected electrically with input of the DC Motor so it's not affected
with the changing of the input current of the DC Motor and has approximately constant current.
The armature resistance
of the DC Motor will be measured. It is not possible to measure the
armature resistance
directly with a conventional ohmmeter because the non-linear characteristic
is too small. The general method used to
of the motor brushes causes incorrect results when
determine the armature resistance
consists in connecting a dc power source to the motor armature
and measuring the voltage required to produce nominal current flow in the armature windings. Power
is not connected to the stator electromagnet to ensure that the motor does not turn, thus
equals
zero. The ratio of the armature voltage
to the armature current yields the armature resistance
directly or the slope of the relation between the voltage and current.
(a) Separately-Excited DC Motor Coupled to a Dynamometer
(b) Separated Magnetic Circuit
Figure 7.5: Separately-Excited DC Motor.
PRACTICAL 7.1.A: MEASURING THE ARMATURE RESISTANCE
ƒ PROCEDURE:
1- Ensure that the power supply (unit 8821-25) is switched off. Then connect the circuit shown
in Figure 7.5.
2- Let the Magnetic circuit open.
3- Increase the input voltage according to Table 7.1.
0
10
20
30
40
Input Voltage
Input Current Table 7.1
4- Draw the graph of the relation between input voltage and input current.
5- Calculate the slope which is the armature resistance of the DC Motor.
6- Switch off the power supply.
PRACTICAL 7.1.B: OUTPUT SPEED VERSUS INPUT VOLTAGE CHARACTERISTIC
ƒ PROCEDURE:
1- Make the necessary connecting between the Dynamometer and the Data Acquisition Interface
in order to receive the result on the computer.
2- Set the LOAD CONTROL knob to the MIN. position (fully CCW).
3- On the DC Motor set the Field Rheostat so that the field current is 190 .
4- On power supply, increase the input voltage of the DC Motor 10% and measure the speed in
every time according to (table 7.2).
Voltage (V)
10%
20%
30%
40%
50%
60%
70%
80%
90% 100%
Speed (r/min)
Table 7.2
5- Turn of the power supply after finishing recording.
6- Draw the graph of the output speed as function of input voltage (what do you observe from
the resulting graph? Why?) then determined the value of from the slope.
PRACTICAL 7.1.C: OUTPUT TORQUE VERSUS CURRENT CHARACTERISTIC
ƒ PROCEDURE:
1- Turn on the power supply then adjust the input voltage to reach the speed to 1500 r/min.
2- In the Metering window, record the dc motor output torque T, armature voltage EA ,
armature current IA , field current IF , and speed n (indicated by meters T, E1, I1, I2, and n,
respectively) in the Data Table. On the Prime Mover / Dynamometer, set the DISPLAY
switch to the TORQUE (T) position then adjust the LOAD CONTROL knob so that the
torque indicated on the module display increases by 0.2 . (2.0
. ) increments up
to 2.0 . (18.0 . ). For each torque setting, readjust the voltage control knob of
the Power Supply so that the armature voltage EA remains equal to the value recorded in
the previous step, then record the data in table 7.3.
Input
Voltage
Output
Torque
.
0.0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
Input
Current
Field
Current
Output
Speed
/
Calculate
d Speed
Input
Power
Output
Power
2
Efficiency
/60
1500
Table 7.3
3- Turn off the power supply.
4- Draw the graph of the output torque as function of input current (what do you observe
from the slope.
from the resulting graph? Why?) Then determined the value of
PRACTICAL 7.1.D: OUTPUT SPEED VERSUS INPUT CURRENT CHARACTERISTIC
1- From table 7.3 draw the graph of the output speed as function of input current.
2- To explain the reason of decreasing the speed with increasing the input current at constant
for every result then calculate the speed input voltage calculate
.
PRACTICAL 7.1.E: OUTPUT TORQUE VERSUS OUTPUT SPEED AND POWER
1- Draw the graph of the output torque as function of output speed from table 7.3.
2- Calculate the input and output power of the DC Motor to determine its efficiency.
PRACTICAL 7.1.F: THE EFFECTS OF CHANGING THE FIELD CURRENT ON THE DC
MOTOR CHARACTERISTIC
1234-
Turn on the power supply.
On the DC Motor set the Field Rheostat so that the field current is 145
Repeat PRACTICAL 6.1.B, (what is happened to ?).
Repeat PRACTICAL 6.1.C, (what is happened to ?)
.
PART2: SERIES, SHUNT AND COMPOUND DC MOTOR
ELEMENTS
ƒ OBJECTIVE:
After completing this part, you will also be able to demonstrate the main operating characteristics
of series, shunt, and compound motors.
ƒ INTRODUCTION:
The series motor is a motor in which the field electromagnet is a series winding connected series
with the armature as shown in Figure 7.6. The strength of the field electromagnet, therefore,
varies as the armature current varies. As a result, and vary when the armature current
varies. Figure 7.6 shows the speed versus torque characteristic of a series motor when the
armature voltage is fixed. This characteristic shows that the speed decreases non-linearly as the
torque increases, i.e. as the armature current increases.
Figure 7.6: Series Motor and its Speed versus Torque Characteristic.
The shunt motor is a motor in which the field electromagnet is a shunt winding connected in parallel
with the armature, both being connected to the same dc voltage source as shown in Figure 7.7. For a
fixed armature voltage, constants
and are fixed, and the speed versus torque characteristic is
very similar to that obtained with a separately-excited dc motor powered by a fixed-voltage dc
source, as shown in Figure 7.7. As in a separately-excited dc motor, the characteristics ( and ) of
a shunt motor can be changed by varying the field current with a rheostat. However, it is difficult to
change the speed of a shunt motor by changing the armature voltage, because this changes the field
current, and thereby, the motor characteristics, in a way that opposes speed change.
Figure 7.7: Shunt Motor and its Characteristics.
It is possible to combine shunt and series windings to obtain a particular speed versus torque
characteristic. For example, to obtain the characteristic of decreasing speed when the motor torque
increases, a series winding can be connected in series with the armature so that the magnetic flux it
produces adds with the magnetic flux produced by a shunt winding. As a result, the magnetic flux
increases automatically with increasing armature current. This type of dc motor is referred to as a
cumulative compound motor because the magnetic fluxes produced by the series and shunt windings
add together. Shunt and series windings can also be connected so that the magnetic fluxes subtract
from each other. This connection produces a differential compound motor, which is rarely used
because the motor becomes unstable when the armature current increases. Figure 7.8 shows a
compound motor and its speed versus torque characteristic (cumulative compound).
Figure 7.8: Compound Motor and its Speed versus Torque Characteristic.
PRACTICAL 7.2.A: SERIES DC MOTOR CHARACTERISTICS
1- Ensure that the power supply (unit 8821-25) is switched off.
2- Make the needed change on the previous connection to get the connection in figure 7.9.
Figure 7.9: Series Motor Coupled to a Dynamometer.
3- In the Metering window, record the dc motor output torque T, armature voltage EA , armature
current IA , and speed n (indicated by meters T, E1, I1, and n, respectively) in the Data Table.
On the Prime Mover / Dynamometer, set the DISPLAY switch to the TORQUE (T) position
then adjust the LOAD CONTROL knob so that the torque indicated on the module display
increases by 0.2 . (2.0
. ) increments up to 2.0 . (18.0 . ). For each torque
setting, readjust the voltage control knob of the Power Supply so that the armature voltage EA
remains equal to the value recorded in the previous step, then record the data in table 7.3.
4- Draw the graph of the output torque as function of output speed
PRACTICAL 7.2.B: SHUNT DC MOTOR CHARACTERISTICS
1- Ensure that the power supply (unit 8821-25) is switched off.
2- Make the needed change on the previous connection to get the connection in figure 7.10.
Figure 7.10: Shunt Motor Coupled to a Dynamometer.
3- In the Metering window, record the dc motor output torque T, armature voltage EA , armature
current IA , field current IF , and speed n (indicated by meters T, E1, I1, I2, and n, respectively)
in the Data Table. On the Prime Mover / Dynamometer, set the DISPLAY switch to the
TORQUE (T) position then adjust the LOAD CONTROL knob so that the torque indicated
on the module display increases by 0.2 .
(2.0
. ) increments up to 2.0 .
(18.0 . ). For each torque setting, readjust the voltage control knob of the Power Supply
so that the armature voltage EA remains equal to the value recorded in the previous step, then
record the data in table 7.3.
4- Draw the graph of the output torque as function of output speed.
PRACTICAL 7.2.C: CUMULATIVE COMPOUND DC MOTOR
1- Ensure that the power supply (unit 8821-25) is switched off.
2- Make the needed change on the previous connection to get the connection in figure 7.9.
Figure 7.6: Cumulative Compound DC Motor Coupled to a Dynamometer.
3- Repeat 3, 4 from PRACTICAL 7.2.B.
4- Compare between the result on 7.1.E, 7.2.A, 7.2.B and 7.2.C.
PRACTICAL ASPECTS:
‐
‐
‐
The series motor provides a strong starting torque and a wide range of operating speeds
when it is supplied by a fixed-voltage dc source. However, the speed, torque, and
armature current depend on the mechanical load applied to the motor. Also, the series
motor has non-linear operating characteristics as suggested by the speed versus torque
relationship. As a result, it is difficult to operate a series motor at a constant speed when
the mechanical load fluctuates. Furthermore, the armature current must be limited to
prevent damages to the motor when it is starting (when power is applied to the motor).
Finally, a series motor must never run with no-mechanical load because the speed
increases to a very-high value which can damage the motor (motor runaway.)
Today, series motors can operate with fixed-voltage power sources, for example,
automobile starting motors; or with variable-voltage power sources, for example, traction
systems.
The main advantage of a shunt motor is the fact that only a single fixed-voltage dc source
is required to supply power to both the armature and the shunt winding. Also, speed
varies little as the mechanical load varies. However, a shunt motor has a limited speed
range because speed cannot be easily varied by varying the armature voltage.
Furthermore, the armature current must be limited to prevent damage to the motor when it
is starting (when power is applied to the motor). Finally, when the shunt winding opens
accidentally, the field current IF becomes zero, the motor speed increases rapidly, and
motor runaway occurs as suggested by the speed versus field current characteristic.
The main feature of cumulative compound motor characteristics is that the motor speed
varies little and linearly as the torque varies. On the other hand, the series motor
characteristic is non linear and shows that the motor speed varies a lot (wide range of
operating speed) as the torque varies. Finally, the characteristic of a cumulative
compound motor is a compromise of the series and shunt motor characteristics. It
provides the compound motor with a fairly wide range of operating speed, but the speed
does not vary linearly as the torque varies.