Vital Relays and Timers Ansaldo STS USA (Formerly known as Union Switch & Signal) Rev. 4-11 Electronic Relay Reset Module ASTS USA’s Electronic Relay Reset Module supports the PV250E and TRU-III units in MicroLok II cab signal track circuit applications that do not incorporate a Track Relay. Using an output of this module, the PV-250E or TRU-III can provide a direct input to MicroLok II for train detection, or use an ASTS USA PN-150B vital relay for this purpose. LEDs on the Reset Module show the on/off state of its output. Description In MicroLok II-controlled cab signal applications, steady energy is restored to track circuit from logic involving sequential track circuit occupancy. On/off coding is generally in the range of 50 to 420 CPM, which is too fast for MicroLok II to recognize and assert its application logic. When a cab signal track circuit has been shunted without a train progressing from one track circuit to another, the Reset Module (responding to a PV-250E or TRU-III output) is used to provide an input to MicroLok Advantages (cont’d) II to initiate logic and restore steady energy. The Capable of driving inputs to two redundant Reset Module’s output is designed to drive two MicroLok II units. MicroLok II logic controller input circuits in parallel for redundant systems. Unit easily mounted and wired. The module’s output voltage turn-on time is 2 to 4 seconds after the input starts coding. Turn-off time is LEDs indicate status of outputs. 9 to 13 seconds after the input stops coding. The No calibrations or maintenance required. Module is tested to insure an operating range from 36 to 450 CPM. It will not deliver an output much beyond Built-in short circuit and reversed battery protection. this range. The Reset Module is housed in a compact plastic case designed for rack mounting via a standard DIN rail. All power and data wiring is terminated on the front of the unit with scew-clasped terminals. Red and green status LEDs are provided on the front of the unit. The normal state of the Reset Module output is off with the green LED lit. The red LED lights when the input signal is coded and the output is turned on. This state only persists for about 20 seconds until the MicroLok II unit turns off the cab code rate. Specifications Connections: 3 connector plugs with 4screw terminals each: 1 for input, 1 for battery, 1 for output Input Voltage Range: Terminals 1-4: 10V to 16.2V steady DC or a square wave at cab signal code rate. Minimum of +10V (0 to peak) at proper code frequency required to produce output. The Reset Module is designed to withstand a continuous short circuit condition or accidental reversal of battery connections. Advantages Provides input to initiate MicroLok II logic and restore steady energy condition. Input Current Range: 3.3 to 10 mA over input voltage range Input Frequency Range: 36 to 450 CPM or 0.60 to 7.50 Hz Supports PV-250E relay and TRU-III track resonant units in MicroLok II applications. To order, call 1-800-652-7276 e-mail: [email protected] www.ansaldo-sts.com p. 1 Electronic Relay Reset Module (Formerly known as Union Switch & Signal) Rev. 4-11 Typical Reset Module Application with Redundant MicroLok II Units Specifications (cont’d) Input Voltage Isolation: 2000 Vrms between input terminals and battery/output terminals Batt. Input Voltage Range: 12 Vdc to 16.2 Vdc, less than 1 V(p-p) ripple Ext. Batt. Input Protection: Battery line surge protection device Int. Batt. Input Protection: Built-in Battery Input Current: Output Load: 20 Ma (approx.) with 1500 ohm load connected to output 1500 ohms impedance or higher Output Voltage: @1500 ohms: Output voltage approx. 1V less than input battery voltage. @min. 12V battery: 11V output voltage @max.2V battery: 15.0V output voltage Rec. Wire Sizes: Input: #22 AWG or heavier Battery: #22 AWG or heavier Output: #22 AWG or heavier o o Operating Temp. Range: -40 to +70 C Ordering and Additional Information Refer to ordering Tabulation on catalog page 3 for Electronic Relay Reset Module part number. For additional technical details, request ASTS USA Service Manual SM-8A1.0001 Contact your ASTS Account Executive or any required product application information. , p. 2 Electronic Relay Reset Module (Formerly known as Union Switch & Signal) Rev. 4-11 Reset Module Design and Dimensions Ordering Information Order No. N34801901 Description Electronic Relay Reset Module MicroLok® is a registered trademark of Ansaldo STS USA, Inc. , p. 3 , p. 4