* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download 8536 - Ministry of Commerce and Industry
Electric power system wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Three-phase electric power wikipedia , lookup
Phone connector (audio) wikipedia , lookup
Buck converter wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Electronic engineering wikipedia , lookup
Electrical engineering wikipedia , lookup
Power engineering wikipedia , lookup
History of electric power transmission wikipedia , lookup
Electrician wikipedia , lookup
Telecommunications engineering wikipedia , lookup
Ground (electricity) wikipedia , lookup
Surge protector wikipedia , lookup
Electromagnetic compatibility wikipedia , lookup
Fuse (electrical) wikipedia , lookup
Electrical substation wikipedia , lookup
Voltage optimisation wikipedia , lookup
Sound level meter wikipedia , lookup
Stray voltage wikipedia , lookup
Alternating current wikipedia , lookup
Portable appliance testing wikipedia , lookup
Distribution management system wikipedia , lookup
Earthing system wikipedia , lookup
Opto-isolator wikipedia , lookup
Protective relay wikipedia , lookup
National Electrical Code wikipedia , lookup
Industrial and multiphase power plugs and sockets wikipedia , lookup
8536 853610 853620 853630 853641 853649 853650 853661 853669 853690 electrical apparatus for switching etc, n/ov 1000v Fuses, for a Voltage Not Exceeding 1,000v Automatic Circuit Breakers, for a Voltage Not Exceeding 1,000v Other Apparatus for Protecting Electrical Circuits, Not Exceeding 1,000v Relays, for a Voltage Not Exceeding 60v Other Relays, for a Voltage Not Exceeding 1,000v Switches, for a Voltage Not Exceeding 1,000v Lamp-holders, for a Voltage Not Exceeding 1,000v Plugs and Sockets, for a Voltage Not Exceeding 1,000v Other Apparatus for Making Connections to or in Electrical Circuits American Standards ANSI C37.16-2000, Low-Voltage Power Circuit Breakers and AC Power Circuit Protectors, Preferred Ratings, Related Requirements and Application Recommendations for Applies to all low-voltage power circuit breakers and AC power circuit protectors as covered in C37.13, C37.14, C37.17, C37.18, C37.29, C37.50, and C37.52. ANSI C37.17-1997 (R2003), Trip Devices for AC and General Purpose DC Low-Voltage Power Circuit Breakers Pertains to: 1. direct-acting over-current electro-mechanical trip devices 2. direct-acting over-current electronic trip devices 3. reverse-current trip devices 4. undervoltage trip devices ANSI C37.17-1997, Trip Devices for AC and General Purpose DC Low-Voltage Power Circuit Breakers Pertains to direct-acting overcurrent electro-mechanical trip devices; direct-acting overcurrent electronic trip devices; reverse-current trip devices; and undervoltage trip devices. This is the third Public Review for this standard. This standard was previously listed for public review in the January 7, 1994 and the March 3, 1995 issues of Standards Action. It is being resubmitted owing to substantive changes to the text. International Standards ISO ISO 2315:1980 Aircraft - Two- and four-pole sealed electromagnetic relays, 2 A and 3 A - Clearance and fixing dimensions ISO 5066-1:1986 Aircraft - Hermetically sealed monostable electrical relays, 2A and 3A - Part 1: Operating characteristics and test conditions ISO 5066-2:1986 Aircraft - Hermetically sealed monostable electrical relays, 2A and 3A - Part 2: Type approval tests ISO 5866:1983 Aircraft - 2 and 3A plug-in base change-over relays, Type II, with crimped connections - Clearance and fixing dimensions ISO 5867-1:1996 Aircraft - Electromagnetic relays and contactors - Part 1: General requirements ISO 7588-1:1998 Road vehicles - Electrical/electronic switching devices Part 1: Relays and flashers ISO 6550-1:1994 Road vehicles - Sheath-type glow-plugs with conical seating and their cylinder head housing - Part 1: M14 x 1,25 glow-plugs ISO 6550-2:1994 Road vehicles - Sheath-type glow-plugs with conical seating and their cylinder head housing - Part 2: M12 x 1,25 glow-plugs ISO 6550-3:2002 Road vehicles - Sheath-type glow-plugs with conical seating and their cylinder head housing - Part 3: M10 glow-plugs ISO 6550-4:2005 Road vehicles - Sheath-type glow-plugs with conical seating and their cylinder head housing - Part 4: M8 x 1 glow-plugs ISO 7578:2001 Road vehicles - Sheath-type glow-plugs - General requirements and test methods ISO 3189-1:1985 Sockets for wire ropes for general purposes - Part 1: General characteristics and conditions of acceptance ISO 3189-2:1985 Sockets for wire ropes for general purposes - Part 2: Special requirements for sockets produced by forging or machined from the solid ISO 3189-3:1985 Sockets for wire ropes for general purposes - Part 3: Special requirements for sockets produced by casting ISO 7279:1984 Polypropylene (PP) fittings for pipes under pressure Sockets for fusion using heated tools - Metric series Dimensions of sockets ISO 7279:1984 Polypropylene (PP) fittings for pipes under pressure Sockets for fusion using heated tools - Metric series Dimensions of sockets ISO 11446:2004 Road vehicles - Connectors for the electrical connection of towing and towed vehicles - 13-pole connectors for vehicles with 12 V nominal supply voltage ISO 1185:2003 Road vehicles - Connectors for the electrical connection of towing and towed vehicles - 7-pole connector type 24 N (normal) for vehicles with 24 V nominal supply voltage ISO 11992-1:2003 Road vehicles - Interchange of digital information on electrical connections between towing and towed vehicles - Part 1: Physical and data-link layers ISO 11992-2:2003 Road vehicles - Interchange of digital information on electrical connections between towing and towed vehicles - Part 2: Application layer for brakes and running gear ISO 11992-3:2003 Road vehicles - Interchange of digital information on electrical connections between towing and towed vehicles - Part 3: Application layer for equipment other than brakes and running gear ISO 11992-4:2005 Road vehicles - Interchange of digital information on electrical connections between towing and towed vehicles - Part 4: Diagnostics ISO 12098:2004 Road vehicles - Connectors for the electrical connection of towing and towed vehicles - 15-pole connector for vehicles with 24 V nominal supply voltage ISO 1724:2003 Road vehicles - Connectors for the electrical connection of towing and towed vehicles - 7-pole connector type 12 N (normal) for vehicles with 12 V nominal supply voltage ISO 3731:2003 Road vehicles - Connectors for the electrical connection of towing and towed vehicles - 7-pole connector type 24 S (supplementary) for vehicles with 24 V nominal supply voltage ISO 3732:2003 Road vehicles - Connectors for the electrical connection of towing and towed vehicles - 7-pole connector type 12 S (supplementary) for vehicles with 12 V nominal supply voltage ISO 4091:2003 Road vehicles - Connectors for the electrical connection of towing and towed vehicles - Definitions, tests and requirements ISO 4165:2001 Road vehicles - Electrical connections - Double-pole connection ISO 7638-1:2003 Road vehicles - Connectors for the electrical connection of towing and towed vehicles - Part 1: Connectors for braking systems and running gear of vehicles with 24 V nominal supply voltage ISO 7638-2:2003 Road vehicles - Connectors for the electrical connection of towing and towed vehicles - Part 2: Connectors for braking systems and running gear of vehicles with 12 V nominal supply voltage IEC IEC 60050-441 Amd.1 Ed. 2.0 b:2000 "Amendment 1 - International Electrotechnical Vocabulary. Switchgear, controlgear and fuses" IEC 60050-441 Ed. 2.0 t:1984 "International Electrotechnical Vocabulary. Switchgear, controlgear and fuses" IEC 60077-5 Ed. 1.0 b:2003 Railway applications - Electric equipment for rolling stock - Part 5: Electrotechnical components - Rules for HV fuses "Gives additional or amended rules for high voltage fuses as a supplement to those given by IEC 60077-2. States specifically the characteristics of the fuses, their service conditions, the tests to be performed, and the markings. " IEC 60127-1 Ed. 2.0 en:2006 Miniature fuses - Part 1: Definitions for miniature fuses and general requirements for miniature fuse-links "This part of IEC 60127 covers the general requirements and tests applicable to all types of miniature fuse-links (e.g. cartridge fuse-links, sub-miniature fuse-links and universal modular fuse-links) for the protection of electric appliances, electronic equipment and component parts thereof normally intended to be used indoors." IEC 60127-10 Ed. 1.0 b:2001 Miniature fuses - Part 10: User guide for miniature fuses "Relates to miniature fuses for the protection of electric appliances, electronic equipment and component parts thereof, normally intended to be used indoors, as specified in IEC 60127-2, 60127-3 and 60127-4. It relates to fuse-holders for miniature fuse-links according to IEC 60127-6. The object of this guide is to introduce the user to the important properties of miniature fuse-links and fuse-holders for miniature fuses-links and to give some guidance on applying them." IEC 60127-2 Amd.1 Ed. 2.0 b:2003 Amendment 1 - Miniature fuses - Part 2: Cartridge fuse-links IEC 60127-2 Ed. 2.1 b:2003 Miniature fuses - Part 2: Cartridge fuse-links "Relates to special requirements applicable to cartridge fuse-links for miniature fuses with dimensions of 5 mm x 20 mm and 6.3 mm x 32 mm for the protection of electric appliances, electronic equipment and component parts thereof, normally intended for use indoors. " IEC 60127-3 Amd.1 Ed. 2.0 b:1991 Amendment 1 - Miniature fuses - Part 3: Sub-miniature fuse-links IEC 60127-3 Amd.2 Ed. 2.0 b:2002 Amendment 2 - Miniature fuses - Part 3: Sub-miniature fuse-links IEC 60127-3 Ed. 2.0 b:1988 Miniature fuses - Part 3: Sub-miniature fuse-links "This standard relates to special requirements applicable to sub-miniature fuse-links adapted to printed circuits and used for the protection of electric appliances, electronic equipment and component parts thereof, normally intended to be used indoors. This standard also applies to the requirements of IEC 60127-1. " IEC 60127-4 Ed. 3.0 b:2005 Miniature fuses - Part 4: Universal modular fuse-links (UMF) - Through-hole and surface mount types "This part of IEC 60127 relates to universal modular fuse-links (UMF) for printed circuits and other substrate systems, used for the protection of electric appliances, electronic equipment, and component parts thereof, normally intended to be used indoors. It does not apply to fuse-links for appliances intended to be used under special conditions, such as in a corrosive or explosive atmosphere. This standard applies in addition to the requirements of IEC 60127-1." IEC 60127-5 Ed. 1.0 b:1988 Miniature fuses - Part 5: Guidelines for quality assessment of miniature fuse-links "Gives a guide for tests for assessing the quality of miniature fuse-links other than type tests, for the case where there is no complete agreement between the user and the manufacturer on what such tests should be. " IEC 60127-6 Amd.1 Ed. 1.0 b:1996 Amendment 1 - Miniature fuses - Part 6: Fuse-holders for miniature cartridge fuse-links IEC 60127-6 Amd.2 Ed. 1.0 b:2002 Amendment 2 - Miniature fuses - Part 6: Fuse-holders for miniature cartridge fuse-links IEC 60127-6 Ed. 1.0 b:1994 Miniature fuses - Part 6: Fuse-holders for miniature cartridge fuse-links "Applicable to fuse-holders for miniature cartridge fuse-links according to IEC 60127-2 and sub-miniature fuse-links according to IEC 60127-3 for the protection of electric appliances, electronic equipment and component parts thereof, normally intended for use indoors. Replaces IEC 60257 " IEC 60127-6 Ed. 1.0 b:1994 Miniature fuses - Part 6: Fuse-holders for miniature cartridge fuse-links "Applicable to fuse-holders for miniature cartridge fuse-links according to IEC 60127-2 and sub-miniature fuse-links according to IEC 60127-3 for the protection of electric appliances, electronic equipment and component parts thereof, normally intended for use indoors. Replaces IEC 60257 " IEC 60269-1 Ed. 4.0 b:2006 Low-voltage fuses - Part 1: General requirements "This part of IEC 60269 is applicable to fuses incorporating enclosed current-limiting fuse-links with rated breaking capacities of not less than 6 kA, intended for protecting power-frequency a.c. circuits of nominal voltages not exceeding 1 000 V or d.c. circuits of nominal voltages not exceeding 1 500 V. Subsequent parts of this standard, referred to herein, cover supplementary requirements for such fuses intended for specific conditions of use or applications." IEC 60269-1 Ed. 4.0 b:2006 Low-voltage fuses - Part 1: General requirements "This part of IEC 60269 is applicable to fuses incorporating enclosed current-limiting fuse-links with rated breaking capacities of not less than 6 kA, intended for protecting power-frequency a.c. circuits of nominal voltages not exceeding 1 000 V or d.c. circuits of nominal voltages not exceeding 1 500 V. Subsequent parts of this standard, referred to herein, cover supplementary requirements for such fuses intended for specific conditions of use or applications." IEC 60269-3 Ed. 3.0 b:2006 Low-voltage fuses - Part 3: Supplementary requirements for fuses for use by unskilled persons (fuses mainly for household and similar applications) - Examples of standardized systems of fuses A to F "Fuses for use by unskilled persons according to the following fuse systems comply with all subclauses of IEC 60269-1 and with the requirements laid down in the relevant fuse systems. This standard is divided into six fuse systems, each dealing with a specific example of standardized fuses for use by unskilled persons." IEC 60269-3 Ed. 3.0 b:2006 Low-voltage fuses - Part 3: Supplementary requirements for fuses for use by unskilled persons (fuses mainly for household and similar applications) - Examples of standardized systems of fuses A to F "Fuses for use by unskilled persons according to the following fuse systems comply with all subclauses of IEC 60269-1 and with the requirements laid down in the relevant fuse systems. This standard is divided into six fuse systems, each dealing with a specific example of standardized fuses for use by unskilled persons." IEC 60269-4 Ed. 4.0 b:2006 Low-voltage fuses - Part 4: Supplementary requirements for fuse-links for the protection of semiconductor devices "These supplementary requirements apply to fuse-links for application in equipment containing semiconductor devices for circuits of nominal voltages up to 1 000 V a.c. or 1 500 V d.c. and also, in so far as they are applicable, for circuits of higher nominal voltages." IEC 60282-1 Ed. 6.0 b:2005 High-voltage fuses - Part 1: Current-limiting fuses This part of IEC 60282 applies to all types of high-voltage current-limiting fuses designed for use outdoors or indoors on alternating current systems of 50 Hz and 60 Hz and of rated voltages exceeding 1000 V. IEC 60282-2 Ed. 2.1 b:1997 High-voltage fuses - Part 2: Expulsion fuses "Specifies requirements for expulsion fuses designed for use outdoors or indoors on alternating current systems of 50 Hz and 60 Hz, and of rated voltages exceeding 1 000 V. " IEC 60549 Ed. 1.0 b:1976 High-voltage fuses for the external protection of shunt power capacitors Applies to external fuses used with high-voltage capacitors for use on alternating current systems of 50 Hz and 60 Hz. Formulates uniform requirements and test procedures regarding performance and testing of fuses intended to be used for capacitor protection. Lists information to be given to the user. IEC/TR 61818 Ed. 1.0 b:2003 Application guide for low-voltage fuses "This guide for low-voltage fuses shows how current-limiting fuses are easy to apply to protect today's complex and sensitive electronic equipment. It specifically covers low-voltage fuses up to a.c. 1 000 V and d.c. 1 500 V. Provides information on the application of fuses which are not always covered, as well as important facts which are sometimes difficult to locate in standards." IEC 60146-1-1 Ed. 3.0 b:1991 Semiconductor convertors - General requirements and line commutated convertors - Part 1-1: Specifications of basic requirements Part 1-1: Specifications of basic requirements Specifies the requirements for the performance of all electronic power convertors and electronic power switches using controllable and/or non-controllable electronic valves. Specifies the requirements applicable to line commutated convertors for conversion of a.c. power to d.c. power or vice versa including tests and service conditions which influence the basis of rating. IEC 60265-1 Ed. 3.0 b:1998 High-voltage switches - Part 1: Switches for rated voltages above 1 kV and less than 52 kV "Is applicable to three-phase, alternating current switches and switch-disconnectors having making and breaking current ratings, for indoor and outdoor installations, for rated voltages above 1 kV and less than 52 kV and for rated frequencies from 16 2/3 Hz up to and including 60 Hz. This standard is also applicable to the operating devices of these switches and to their auxiliary equipment. " IEC 60265-2 Amd.1 Ed. 1.0 b:1994 Amendment 1 - High-voltage switches. Part 2: High-voltage switches for rated voltages of 52 kV and above IEC 60265-2 Amd.2 Ed. 1.0 b:1998 Amendment 2 - High-voltage switches. Part 2: High-voltage switches for rated voltages of 52 kV and above IEC 60265-2 Ed. 1.0 b:1988 High-voltage switches. Part 2: High-voltage switches for rated voltages of 52 kV and above "Applicable to three-phase alternating-current switches, having making and breaking current ratings, for indoor and outdoor installations, for rated voltages 52 kV and above, and for rated frequencies up to and including 60 Hz. " IEC 60388-1 Ed. 1.0 b:1972 Thermal time delay switches for use in equipment for telecommunications and in electronic applications employing similar techniques. Part 1: General requirements and measuring methods Defines general requirements and measuring methods applicable to thermal time delay switches for use in equipment for telecommunication and in electronic applications employing similar techniques. IEC 60389-1 Amd.1 Ed. 1.0 b:1976 Amendment 1 - Thermostatic switches primarily for use in equipment for telecommunications and in electronic applications employing similar techniques. Part 1: General requirements and measuring methods IEC 60389-1 Ed. 1.0 b:1972 Thermostatic switches primarily for use in equipment for telecommunications and in electronic applications employing similar techniques. Part 1: General requirements and measuring methods "Establishes, for thermostatic switches, uniform requirements for the electrical, thermal, climatic and mechanical properties as well as safety aspects and test methods. " IEC 60669-1 Amd.1 Ed. 3.0 b:1999 Amendment 1 - Switches for household and similar fixed-electrical installations - Part 1: General requirements IEC 60669-1 Amd.2 Ed. 3.0 b:2006 Amendment 2 - Switches for household and similar fixed-electrical installations - Part 1: General requirements IEC 60669-1 Ed. 3.1 b:2000 Switches for household and similar fixed-electrical installations - Part 1: General requirements "Applies to manually operated general purpose switches for a.c. only, with a rated voltage not exceeding 440 V and a rated current not exceeding 63 A. " IEC 60669-2-1 Ed. 4.0 b:2002 Switches for household and similar fixed electrical installations - Part 2-1: Particular requirements Electronic switches Applies to electronic switches and to associated electronic extension units for household and similar fixed electrical installations either indoors or outdoors. IEC 60669-2-2 Ed. 3.0 b:2006 Switches for household and similar fixed electrical installations - Part 2-2: Particular requirements Electromagnetic remote-control switches (RCS) "This part of IEC 60669 applies to electromagnetic remote-control switches (hereinafter referred to as RCS) with a rated voltage not exceeding 440 V and a rated current not exceeding 63 A, intended for household and similar fixed electrical installations, either indoors or outdoors." IEC 60669-2-3 Ed. 3.0 b:2006 Switches for household and similar fixed electrical installations - Part 2-3: Particular requirements Time-delay switches (TDS) "This part of IEC 60669 applies to time-delay switches (hereinafter referred to as TDS) with a rated voltage not exceeding 440 V and a rated current not exceeding 63 A, intended for household and similar fixed electrical installations, either indoors or outdoors, operated by hand and/or by remote control. " IEC 60669-2-4 Ed. 1.0 b:2004 Switches for household and similar fixed electrical installations - Part 2-4: Particular requirements Isolating switches "This part of IEC 60669 applies to manually operated general purpose isolating switches with a rated voltage not exceeding 440 V and a rated current not exceeding 125 A, intended for household and similar fixed electrical installations, either indoors or outdoors. " IEC 61020-6-2 Ed. 1.0 b:1994 "Electromechanical switches for use in electronic equipment - Part 6: Sectional specification for sensitive switches - Section 2: Detail specification for one pole, unsealed subminiature sensitive switches, 250 V maximum, 5 A maximum electrical rating" IEC 61058-1 Amd.1 Ed. 3.0 b:2001 Amendment 1 - Switches for appliances - Part 1: General requirements IEC 61058-1 Ed. 3.1 b:2001 Switches for appliances - Part 1: General requirements "Applies to switches for appliances actuated by hand, by foot or by other human activity for use in, on or with appliances and other equipment for household and similar purposes, with a rated voltage not exceeding 440 V and a rated current not exceeding 63 A. Also covers the indirect actuation of the switch when the function of the actuating member is provided by a part of an appliance or equipment. Replaces IEC 60328 (1972)." IEC 61058-2-1 Amd.1 Ed. 1.0 b:1995 Amendment 1 - Switches for appliances - Part 2-1: Particular requirements for cord switches IEC 61058-2-1 Ed. 1.0 b:1992 Switches for appliances - Part 2-1: Particular requirements for cord switches "Applies to cord switches for appliances actuated by hand, by foot or by other human activity for use in, on or with appliances and other equipment for household and similar purposes, with a rated voltage not exceeding 250 V and a rated current not exceeding 16 A. " IEC 61058-2-4 Amd.1 Ed. 1.0 b:2003 Amendment 1 - Switches for appliances - Part 2-4: Particular requirements for independently mounted switches IEC 61058-2-4 Ed. 1.1 b:2003 Switches for appliances - Part 2-4: Particular requirements for independently mounted switches "Applies to independently mounted switches for appliances actuated by hand, by foot or by other human activity for use with appliances and other equipment for household and similar purposes, with a rated voltage not exceeding 440 V and a rated current not exceeding 63 A." IEC 61058-2-5 Ed. 1.0 b:1994 Switches for appliances - Part 2-5: Particular requirements for change-over selectors "Applies to change-over selectors for appliances actuated by hand, by foot or by other human activity for use in, on, or with appliances and other equipment for household and similar purposes, with a rated voltage not exceeding 440 V and a rated current not exceeding 63 A." IEC 60050-446 Ed. 1.0 t:1983 International Electrotechnical Vocabulary. Electrical relays IEC 60255-11 Ed. 1.0 b:1979 Electrical relays - Part 11: Interruptions to and alternating component (ripple) in d.c. auxiliary energizing quantity of measuring relays IEC 60255-12 Ed. 1.0 b:1980 Electrical relays - Part 12: Directional relays and power relays with two input energizing quantities Specifies performance requirements for the subfamily as shown in the title. This publication forms part of a series dealing with measuring relays with more than one input energizing quantity and for which IEC 60255-6 gives the general requirements. IEC 60255-13 Ed. 1.0 b:1980 Electrical relays - Part 13: Biased (percentage) differential relays Specifies performance requirements for the subfamily. Forms part of a series dealing with measuring relays with more than one input energizing quantity and for which IEC 60255-6 gives the general requirements. IEC 60255-16 Ed. 1.0 b:1982 Electrical relays - Part 16: Impedance measuring relays Specifies the general requirements for impedance measuring relays. Covers test methods and methods of presenting relay characteristics and performance. IEC 60255-21-1 Ed. 1.0 b:1988 "Electrical relays - Part 21: Vibration, shock, bump and seismic tests on measuring relays and protection equipment - Section One: Vibration tests (sinusoidal)" "This part includes two types of vibration tests: the vibration response test and the vibration endurance test, and is generally based upon IEC 68-2-6. The requirements are applicable only to measuring relays and protection equipment in a new condition. The tests specified are type tests. " IEC 60255-21-2 Ed. 1.0 b:1988 "Electrical relays - Part 21: Vibration, shock, bump and seismic tests on measuring relays and protection equipment - Section Two: Shock and bump tests" "This standard includes two types of tests: -the shock test (on energized and non-energized specimen), -the bump test (on non-energized specimen). These requirements are applicable only to measuring relays and protection equipment in a new condition. " IEC 60255-21-3 Ed. 1.0 b:1993 "Electrical relays - Part 21: Vibration, shock, bump and seismic tests on measuring relays and protection equipment - Section 3: Seismic tests" "Specifies the vibration, shock, bump and seismic tests applicable to electromechanical and static measuring relays and protection equipment, with or without output contacts. " IEC 60255-22-1 Ed. 2.0 b:2005 Electrical relays - Part 22-1: Electrical disturbance tests for measuring relays and protection equipment - 1 MHz burst immunity tests "Specifies the general requirements for 1 MHz burst immunity tests for measuring relays and protection equipment for power system protection, including the control, monitoring and process interface equipment used with those systems. Is to be used in conjunction with IEC 61000-4-12." IEC 60255-22-2 Ed. 2.0 b:1996 Electrical relays - Part 22: Electrical disturbance tests for measuring relays and protection equipment - Section 2: Electrostatic discharge tests Specifies general requirements for electrostatic discharge tests of static measuring relays and protection equipment. Is based on IEC 1000-4-2 and refers to that standard where applicable. IEC 60255-22-3 Ed. 2.0 b:2000 Electrical relays - Part 22-3: Electrical disturbance tests for measuring relays and protection equipment - Radiated electromagnetic field disturbance tests "Specifies the general requirements for radiated electromagnetic field disturbance tests for measuring relays and protection equipment for power system protection, including the control, monitoring and process interface equipment used with those systems. Is based on IEC 61000-4-3." IEC 60255-22-4 Ed. 2.0 b:2002 Electrical relays - Part 22-4: Electrical disturbance tests for measuring relays and protection equipment - Electrical fast transient/burst immunity test "Specifies the general requirements for electrical fast transient immunity tests for measuring relays and protection equipment for power system protection, including the control, monitoring and process interface equipment used with these systems. Is based on IEC 61000-4-4. " IEC 60255-22-5 Ed. 1.0 b:2002 Electrical relays - Part 22-5: Electrical disturbance tests for measuring relays and protection equipment - Surge immunity test "Specifies the general requirements for surge tests for measuring relays and protection equipment for power system protection, including the control, monitoring and process interface equipment used with these systems. Is based on IEC 61000-4-5." IEC 60255-22-6 Ed. 1.0 b:2001 Electrical relays - Part 22-6: Electrical disturbance tests for measuring relays and protection equipment - Immunity to conducted disturbances induced by radio frequency fields "Specifies the general requirements for conducted disturbances induced by electromagnetic fields for measuring relays and protection equipment for power system protection, including the control, monitoring and process interface equipment used with those systems." IEC 60255-22-7 Ed. 1.0 b:2003 Electrical relays - Part 22-7: Electrical disturbance tests for measuring relays and protection equipment - Power frequency immunity tests "Specifies general requirements for power frequency immunity tests for measuring relays and protection equipment for power system protection, including the control, monitoring and process interface equipment used with those systems. The objective of the tests is to confirm that the equipment under test will operate correctly when energised and subjected to short duration, conducted, common and differential mode power frequency disturbances. Is based on IEC 61000-4-16." IEC 60255-24 Ed. 1.0 b:2001 Electrical relays - Part 24: Common format for transient data exchange (COMTRADE) for power systems Defines a format for files containing transient waveform and event data collected from power systems or power system models. Applies to files stored on physical media such as digital hard drives and diskettes. IEC 60255-25 Ed. 1.0 b:2000 Electrical relays - Part 25: Electromagnetic emission tests for measuring relays and protection equipment "Specifies the general requirements for the measurement of radio-frequency emissions emanating from measuring relays and protection equipment for power system protection, including the control, monitoring and process interface equipment used with such systems. Is based on CISPR 22." IEC 60255-26 Ed. 1.0 b:2004 Electrical relays - Part 26: Electromagnetic compatibility requirements for measuring relays and protection equipment "Specifies the requirements for electromagnetic compatibility for measuring relays and protection equipment. Is applicable to measuring relays and protection equipment for power system protection, including the control, monitoring and process interface equipment used with those systems." IEC 60255-3 Ed. 2.0 b:1989 Electrical relays - Part 3: Single input energizing quantity measuring relays with dependent or independent time Definitions. Standard values relating to energizing quantities influencing quantities. Fundamental characteristics relating to temperature rises and behaviour in service. Accuracy requirements relating to the characteristic quantity and specified times. Mechanical and electrical requirements. Markings and data. Methods of measurement. IEC 60255-5 Ed. 2.0 b:2000 Electrical Relays - Part 5: Insulation coordination for measuring relays and protection equipment Requirements and tests Lays down general requirements for the insulation coordination of measuring relays and protection equipment. Gives guidance for the selection of clearances and creepage distances and other aspects related to the insulation of measuring relays and protection equipment; specifies requirements for voltage tests and insulation resistance measurement. IEC 60255-6 Ed. 2.0 b:1988 Electrical relays - Part 6: Measuring relays and protection equipment This standard specifies the general performance requirements of all electrical measuring relays and protection equipment used in the electrotechnical fields covered by the IEC. Supersedes IEC 60255-6 (1978) and its first supplement 60255-6 A (1980). IEC 60255-8 Ed. 2.0 b:1990 Electrical relays - Part 8: Thermal electrical relays This edition supersedes the first edition of IEC 60255-8 (1978) and IEC 60255-17 (1982). Applies to dependent specified time electrical measuring relays which protect equipment from electrical thermal damage by the measurement of current flowing in protected equipment. States the particular requirements for thermal electrical relays. Is to be read in conjunction with higher level documents in the IEC 60255 series. IEC 60309-1 Amd.1 Ed. 4.0 b:2005 "Amendment 1 - Plugs, socket-outlets and couplers for industrial purposes - Part 1: General requirements " IEC 60309-1 Ed. 4.1 b:2005 "Plugs, socket-outlets and couplers for industrial purposes - Part 1: General requirements" "This standard applies to plugs and socket-outlets, cable couplers and appliance couplers, with a rated operating voltage not exceeding 690 V d.c. or a.c. and 500 Hz a.c., and a rated current not exceeding 250 A, primarily intended for industrial use, either indoors or outdoors." IEC 60309-2 Amd.1 Ed. 4.0 b:2005 "Amendment 1 - Plugs, socket-outlets and couplers for industrial purposes - Part 2: Dimensional interchangeability requirements for pin and contact-tube accessories " IEC 60309-2 Ed. 4.1 b:2005 "Plugs, socket-outlets and couplers for industrial purposes - Part 2: Dimensional interchangeability requirements for pin and contact-tube accessories" "This standard applies to plugs and socket-outlets, cable couplers and appliance couplers with a rated operating voltage not exceeding 690 V, 500 Hz and a rated current not exceeding 125 A, primarily intended for industrial use, either indoors or outdoors. " IEC 60309-4 Ed. 1.0 b:2006 "Plugs, socket-outlets and couplers for industrial purposes - Part 4: Switched socket-outlets and connectors with or without interlock " "This part of IEC 60309 applies to self-contained products that combine within a single enclosure, a socket-outlet or connector according to IEC 60309-1 or IEC 60309-2 and a switching device, with a rated operating voltage not exceeding 690 V d.c. or a.c. and 500 Hz , and a rated current not exceeding 250 A, primarily intended for industrial use, either indoors or outdoors." IEC 60884-1 Amd.1 Ed. 3.0 b:2006 Amendment 1 - Plugs and socket-outlets for household and similar purposes - Part 1: General requirements IEC 60884-1 Ed. 3.1 b:2006 Plugs and socket-outlets for household and similar purposes - Part 1: General requirements "This part of IEC 60884 applies to plugs and fixed or portable socket-outlets for a.c. only, with or without earthing contact, with a rated voltage greater than 50 V but not exceeding 440 V and a rated current not exceeding 32 A, intended for household and similar purposes, either indoors or outdoors." IEC 60884-2-1 Ed. 2.0 b:2006 Plugs and socket-outlets for household and similar purposes - Part 2-1: Particular requirements for fused plugs "This part of IEC 60884 applies to fused plugs, where the fuses are primarily intended to protect the flexible cable or cord. These fuses are not intended to protect appliances or parts of them against overload. " IEC 60884-2-2 Ed. 2.0 b:2006 Plugs and socket-outlets for household and similar purposes - Part 2-2: Particular requirements for socket-outlets for appliances "This part of IEC 60884 applies to socket-outlets for a.c. only, with or without earthing contact, with a rated voltage not exceeding 250 V and a rated current not exceeding 16 A, which are integrated or intended to be incorporated in or fixed to appliances, hereafter referred to as socket-outlets for appliances." IEC 60884-2-3 Ed. 2.0 b:2006 Plugs and socket-outlets for household and similar purposes - Part 2-3: Particular requirements for switched socket-outlets without interlock for fixed installations "This part of IEC 60884 applies to switched socket-outlets without interlock, for fixed installation, for a.c. only, with or without earthing contact, with a rated voltage not exceeding 440 V and a rated current not exceeding 32A, intended for household and similar purposes, either indoors or outdoors." IEC 60884-2-4 Ed. 2.0 b:1999 Plugs and socket-outlets for household and similar purposes - Part 2-4: Particular requirements for plugs and socket-outlets for SELV "Applies to plugs, fixed or portable socket-outlets, and to socket-outlets for appliances with d.c. or a.c. (50/60 Hz) SELV with rated current of 16 A. " IEC 60884-2-5 Ed. 1.0 b:1995 Plugs and socket-outlets for household and similar purposes - Part 2: Particular requirements for adaptors "This standard applies to shuttered and non-shuttered, fused and non-fused adaptors for a.c. only. " IEC 60884-2-6 Ed. 1.0 b:1997 Plugs and socket-outlets for household and similar purposes - Part 2-6: Particular requirements for switched socket-outlets with interlock for fixed electrical installations "Applies to switched socket-outlets with interlock for a.c. only, for fixed electrical installations, with or without earthing contact, with rated voltage above 50 V but not exceeding 440 V and a rated current not exceeding 32 A, intended for household and similar purposes, either indoors or outdoors." IEC 60906-1 Ed. 1.0 b:1986 IEC system of plugs and socket-outlets for household and similar purposes - Part 1: Plugs and socket-outlets 16 A 250 V a.c. "Applies to the IEC System of plugs and socket-outlets rated 16 A 250 V a.c. for household and similar purposes for the connection of equipment to distribution systems having nominal voltages between 200 V and 250 V a.c., in so far as dimensional requirements are concerned. The object of this part is to provide a standard for a safe, compact and practical IEC 250 V system of plugs and socket-outlets that could be accepted by many countries as their national standard, now or in in the near future. It is therefore recommended that any country in need of a new or replacement system for the nominal voltage range 200 V to 250 V a.c. adopt this standard as its only national standard. " IEC 60906-2 Ed. 2.0 b:1997 IEC system of plugs and socket-outlets for household and similar purposes - Part 2: Plugs and socket-outlets 15 A 125 V a.c. "Applies to the IEC system of plugs and socket-outlets rated 15 A 125 V a.c. for household and similar purposes for the connection of equipment to distribution systems having nominal voltages between 100 V and 125 V a.c. in so far as dimensional requirements are concerned. The object of this part is to provide a standard for a safe, compact and practical IEC 125 V system of plugs and socket-outlets that could be accepted by many countries as their national standard, now or in in the near future. It is therefore recommended that any country in need of a new or replacement system for the nominal voltage range 100 V to 125 V a.c. adopt this standard as its only national standard." IEC 60906-3 Ed. 1.0 b:1994 "IEC System of plugs and socket-outlets for household and similar purposes - Part 3: SELV plugs and socket-outlets, 16 A 6V, 12 V, 24 V, 48 V, a.c. and d.c." "Applies to the IEC SELV System of plugs, fixed and portable socket-outlets and to socket-outlets for appliances rated 16 A 6 V, 12 V, 24V, 48 V a.c. and d.c., intended for household and similar purposes, either indoors or outdoors." IEC 62196-1 Ed. 1.0 b:2004 "Plugs, socket-outlets, vehicle couplers and vehicle inlets - Conductive charging of electric vehicles - Part 1: Charging of electric vehicles up to 250 A a.c. and 400 A d.c." "This part of IEC 62196 is applicable to plugs, socket-outlets, connectors, inlets and cable assemblies for electric vehicles, intended for use in conductive charging systems which incorporate control means, with a rated operating voltage not exceeding: 690 V a.c., 50 - 60 Hz, at a rated current not exceeding 250 A; 600 V d.c., at a rated current not exceeding 400 A. " IEC/TR 60083 Ed. 5.0 b:2006 Plugs and socket-outlets for domestic and similar general use standardized in member countries of IEC "The object of this technical report is to give general information about the systems of plugs and socket-outlets for household and similar purposes which are used in the IEC countries. The report only contains National Systems which are commonly used in homes and offices. It is therefore limited to systems for a.c. with a rated voltage above 50 V but not exceeding 440 V, intended for household and similar purposes, either indoors or outdoors. The report only contains systems for which standard sheets have been published in a National Standard, which may be a National Standard of the country itself or any other IEC member country" IECEE CEE-7 Ed. 2.0 b:1963 Specification for plugs and socket-outlets for domestic and similar purpose "This CEE 7 publication originally published as the 2nd edition on 1963-05 also contains Modification 1 (1973-08), Modification 2 (1974-06), Modification 3 (1975-09) and Modification 4 (1983-03). Please note that this standard shall not be used alone, it is to be used in addition to IEC 60884-1."