Download 8536 - Ministry of Commerce and Industry

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Ohm's law wikipedia , lookup

Electric power system wikipedia , lookup

Variable-frequency drive wikipedia , lookup

Three-phase electric power wikipedia , lookup

Phone connector (audio) wikipedia , lookup

Buck converter wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Relay wikipedia , lookup

Electronic engineering wikipedia , lookup

Electrical engineering wikipedia , lookup

Metadyne wikipedia , lookup

Power engineering wikipedia , lookup

History of electric power transmission wikipedia , lookup

Electrician wikipedia , lookup

Telecommunications engineering wikipedia , lookup

Ground (electricity) wikipedia , lookup

Surge protector wikipedia , lookup

Electromagnetic compatibility wikipedia , lookup

Fuse (electrical) wikipedia , lookup

Electrical substation wikipedia , lookup

Voltage optimisation wikipedia , lookup

Sound level meter wikipedia , lookup

Stray voltage wikipedia , lookup

Alternating current wikipedia , lookup

Portable appliance testing wikipedia , lookup

Distribution management system wikipedia , lookup

Earthing system wikipedia , lookup

Opto-isolator wikipedia , lookup

Protective relay wikipedia , lookup

National Electrical Code wikipedia , lookup

Industrial and multiphase power plugs and sockets wikipedia , lookup

Mains electricity wikipedia , lookup

Electrical wiring in the United Kingdom wikipedia , lookup

Transcript
8536
853610
853620
853630
853641
853649
853650
853661
853669
853690
electrical apparatus for switching etc, n/ov 1000v
Fuses, for a Voltage Not Exceeding 1,000v
Automatic Circuit Breakers, for a Voltage Not Exceeding 1,000v
Other Apparatus for Protecting Electrical Circuits, Not Exceeding 1,000v
Relays, for a Voltage Not Exceeding 60v
Other Relays, for a Voltage Not Exceeding 1,000v
Switches, for a Voltage Not Exceeding 1,000v
Lamp-holders, for a Voltage Not Exceeding 1,000v
Plugs and Sockets, for a Voltage Not Exceeding 1,000v
Other Apparatus for Making Connections to or in Electrical Circuits
American Standards
ANSI C37.16-2000, Low-Voltage Power
Circuit Breakers and AC Power Circuit
Protectors, Preferred Ratings, Related
Requirements and Application
Recommendations for
Applies to all low-voltage power circuit breakers
and AC power circuit protectors as covered in
C37.13, C37.14, C37.17, C37.18, C37.29,
C37.50, and C37.52.
ANSI C37.17-1997 (R2003), Trip Devices
for AC and General Purpose DC
Low-Voltage Power Circuit Breakers
Pertains to:
1. direct-acting over-current electro-mechanical
trip devices
2. direct-acting over-current electronic trip
devices
3. reverse-current trip devices
4. undervoltage trip devices
ANSI C37.17-1997, Trip Devices for AC and
General Purpose DC Low-Voltage Power
Circuit Breakers
Pertains to direct-acting overcurrent
electro-mechanical trip devices; direct-acting
overcurrent electronic trip devices;
reverse-current trip devices; and undervoltage
trip devices. This is the third Public Review for
this standard. This standard was previously
listed for public review in the January 7, 1994
and the March 3, 1995 issues of Standards
Action. It is being resubmitted owing to
substantive changes to the text.
International Standards
ISO
ISO 2315:1980
Aircraft - Two- and four-pole sealed electromagnetic
relays, 2 A and 3 A - Clearance and fixing dimensions
ISO 5066-1:1986
Aircraft - Hermetically sealed monostable electrical
relays, 2A and 3A - Part 1: Operating characteristics and
test conditions
ISO 5066-2:1986
Aircraft - Hermetically sealed monostable electrical
relays, 2A and 3A - Part 2: Type approval tests
ISO 5866:1983
Aircraft - 2 and 3A plug-in base change-over relays,
Type II, with crimped connections - Clearance and fixing
dimensions
ISO 5867-1:1996
Aircraft - Electromagnetic relays and contactors - Part 1:
General requirements
ISO 7588-1:1998
Road vehicles - Electrical/electronic switching devices Part 1: Relays and flashers
ISO 6550-1:1994
Road vehicles - Sheath-type glow-plugs with conical
seating and their cylinder head housing - Part 1: M14 x
1,25 glow-plugs
ISO 6550-2:1994
Road vehicles - Sheath-type glow-plugs with conical
seating and their cylinder head housing - Part 2: M12 x
1,25 glow-plugs
ISO 6550-3:2002
Road vehicles - Sheath-type glow-plugs with conical
seating and their cylinder head housing - Part 3: M10
glow-plugs
ISO 6550-4:2005
Road vehicles - Sheath-type glow-plugs with conical
seating and their cylinder head housing - Part 4: M8 x 1
glow-plugs
ISO 7578:2001
Road vehicles - Sheath-type glow-plugs - General
requirements and test methods
ISO 3189-1:1985
Sockets for wire ropes for general purposes - Part 1:
General characteristics and conditions of acceptance
ISO 3189-2:1985
Sockets for wire ropes for general purposes - Part 2:
Special requirements for sockets produced by forging or
machined from the solid
ISO 3189-3:1985
Sockets for wire ropes for general purposes - Part 3:
Special requirements for sockets produced by casting
ISO 7279:1984
Polypropylene (PP) fittings for pipes under pressure Sockets for fusion using heated tools - Metric series Dimensions of sockets
ISO 7279:1984
Polypropylene (PP) fittings for pipes under pressure Sockets for fusion using heated tools - Metric series Dimensions of sockets
ISO 11446:2004
Road vehicles - Connectors for the electrical connection
of towing and towed vehicles - 13-pole connectors for
vehicles with 12 V nominal supply voltage
ISO 1185:2003
Road vehicles - Connectors for the electrical connection
of towing and towed vehicles - 7-pole connector type 24
N (normal) for vehicles with 24 V nominal supply voltage
ISO 11992-1:2003
Road vehicles - Interchange of digital information on
electrical connections between towing and towed
vehicles - Part 1: Physical and data-link layers
ISO 11992-2:2003
Road vehicles - Interchange of digital information on
electrical connections between towing and towed
vehicles - Part 2: Application layer for brakes and
running gear
ISO 11992-3:2003
Road vehicles - Interchange of digital information on
electrical connections between towing and towed
vehicles - Part 3: Application layer for equipment other
than brakes and running gear
ISO 11992-4:2005
Road vehicles - Interchange of digital information on
electrical connections between towing and towed
vehicles - Part 4: Diagnostics
ISO 12098:2004
Road vehicles - Connectors for the electrical connection
of towing and towed vehicles - 15-pole connector for
vehicles with 24 V nominal supply voltage
ISO 1724:2003
Road vehicles - Connectors for the electrical connection
of towing and towed vehicles - 7-pole connector type 12
N (normal) for vehicles with 12 V nominal supply voltage
ISO 3731:2003
Road vehicles - Connectors for the electrical connection
of towing and towed vehicles - 7-pole connector type 24
S (supplementary) for vehicles with 24 V nominal supply
voltage
ISO 3732:2003
Road vehicles - Connectors for the electrical connection
of towing and towed vehicles - 7-pole connector type 12
S (supplementary) for vehicles with 12 V nominal supply
voltage
ISO 4091:2003
Road vehicles - Connectors for the electrical connection
of towing and towed vehicles - Definitions, tests and
requirements
ISO 4165:2001
Road vehicles - Electrical connections - Double-pole
connection
ISO 7638-1:2003
Road vehicles - Connectors for the electrical connection
of towing and towed vehicles - Part 1: Connectors for
braking systems and running gear of vehicles with 24 V
nominal supply voltage
ISO 7638-2:2003
Road vehicles - Connectors for the electrical connection
of towing and towed vehicles - Part 2: Connectors for
braking systems and running gear of vehicles with 12 V
nominal supply voltage
IEC
IEC 60050-441 Amd.1 Ed. 2.0 b:2000 "Amendment 1 - International Electrotechnical
Vocabulary. Switchgear, controlgear and fuses"
IEC 60050-441 Ed. 2.0 t:1984 "International Electrotechnical Vocabulary.
Switchgear, controlgear and fuses"
IEC 60077-5 Ed. 1.0 b:2003 Railway applications - Electric equipment for
rolling stock - Part 5: Electrotechnical components
- Rules for HV fuses
"Gives additional or amended rules for high voltage fuses as a
supplement to those given by IEC 60077-2. States specifically
the characteristics of the fuses, their service conditions, the
tests to be performed, and the markings. "
IEC 60127-1 Ed. 2.0 en:2006 Miniature fuses - Part 1: Definitions for miniature
fuses and general requirements for miniature
fuse-links
"This part of IEC 60127 covers the general requirements and
tests applicable to all types of miniature fuse-links (e.g.
cartridge fuse-links, sub-miniature fuse-links and universal
modular fuse-links) for the protection of electric appliances,
electronic equipment and component parts thereof normally
intended to be used indoors."
IEC 60127-10 Ed. 1.0 b:2001 Miniature fuses - Part 10: User guide for miniature
fuses
"Relates to miniature fuses for the protection of electric
appliances, electronic equipment and component parts
thereof, normally intended to be used indoors, as specified in
IEC 60127-2, 60127-3 and 60127-4. It relates to fuse-holders
for miniature fuse-links according to IEC 60127-6. The object
of this guide is to introduce the user to the important properties
of miniature fuse-links and fuse-holders for miniature
fuses-links and to give some guidance on applying them."
IEC 60127-2 Amd.1 Ed. 2.0 b:2003 Amendment 1 - Miniature fuses - Part 2: Cartridge
fuse-links
IEC 60127-2 Ed. 2.1 b:2003 Miniature fuses - Part 2: Cartridge fuse-links "Relates to special requirements
applicable to cartridge
fuse-links for miniature fuses with dimensions of 5 mm x 20
mm and 6.3 mm x 32 mm for the protection of electric
appliances, electronic equipment and component parts
thereof, normally intended for use indoors. "
IEC 60127-3 Amd.1 Ed. 2.0 b:1991 Amendment 1 - Miniature fuses - Part 3:
Sub-miniature fuse-links
IEC 60127-3 Amd.2 Ed. 2.0 b:2002 Amendment 2 - Miniature fuses - Part 3:
Sub-miniature fuse-links
IEC 60127-3 Ed. 2.0 b:1988 Miniature fuses - Part 3: Sub-miniature fuse-links "This standard relates to
special requirements applicable to
sub-miniature fuse-links adapted to printed circuits and used
for the protection of electric appliances, electronic equipment
and component parts thereof, normally intended to be used
indoors. This standard also applies to the requirements of IEC
60127-1. "
IEC 60127-4 Ed. 3.0 b:2005 Miniature fuses - Part 4: Universal modular
fuse-links (UMF) - Through-hole and surface
mount types
"This part of IEC 60127 relates to universal modular fuse-links
(UMF) for printed circuits and other substrate systems, used
for the protection of electric appliances, electronic equipment,
and component parts thereof, normally intended to be used
indoors. It does not apply to fuse-links for appliances intended
to be used under special conditions, such as in a corrosive or
explosive atmosphere. This standard applies in addition to the
requirements of IEC 60127-1."
IEC 60127-5 Ed. 1.0 b:1988 Miniature fuses - Part 5: Guidelines for quality
assessment of miniature fuse-links
"Gives a guide for tests for assessing the quality of miniature
fuse-links other than type tests, for the case where there is no
complete agreement between the user and the manufacturer
on what such tests should be. "
IEC 60127-6 Amd.1 Ed. 1.0 b:1996 Amendment 1 - Miniature fuses - Part 6:
Fuse-holders for miniature cartridge fuse-links
IEC 60127-6 Amd.2 Ed. 1.0 b:2002 Amendment 2 - Miniature fuses - Part 6:
Fuse-holders for miniature cartridge fuse-links
IEC 60127-6 Ed. 1.0 b:1994 Miniature fuses - Part 6: Fuse-holders for
miniature cartridge fuse-links
"Applicable to fuse-holders for miniature cartridge fuse-links
according to IEC 60127-2 and sub-miniature fuse-links
according to IEC 60127-3 for the protection of electric
appliances, electronic equipment and component parts
thereof, normally intended for use indoors. Replaces IEC
60257 "
IEC 60127-6 Ed. 1.0 b:1994 Miniature fuses - Part 6: Fuse-holders for
miniature cartridge fuse-links
"Applicable to fuse-holders for miniature cartridge fuse-links
according to IEC 60127-2 and sub-miniature fuse-links
according to IEC 60127-3 for the protection of electric
appliances, electronic equipment and component parts
thereof, normally intended for use indoors. Replaces IEC
60257 "
IEC 60269-1 Ed. 4.0 b:2006 Low-voltage fuses - Part 1: General requirements "This part of IEC 60269 is
applicable to fuses incorporating
enclosed current-limiting fuse-links with rated breaking
capacities of not less than 6 kA, intended for protecting
power-frequency a.c. circuits of nominal voltages not
exceeding 1 000 V or d.c. circuits of nominal voltages not
exceeding 1 500 V. Subsequent parts of this standard,
referred to herein, cover supplementary requirements for such
fuses intended for specific conditions of use or applications."
IEC 60269-1 Ed. 4.0 b:2006 Low-voltage fuses - Part 1: General requirements "This part of IEC 60269 is
applicable to fuses incorporating
enclosed current-limiting fuse-links with rated breaking
capacities of not less than 6 kA, intended for protecting
power-frequency a.c. circuits of nominal voltages not
exceeding 1 000 V or d.c. circuits of nominal voltages not
exceeding 1 500 V. Subsequent parts of this standard,
referred to herein, cover supplementary requirements for such
fuses intended for specific conditions of use or applications."
IEC 60269-3 Ed. 3.0 b:2006 Low-voltage fuses - Part 3: Supplementary
requirements for fuses for use by unskilled
persons (fuses mainly for household and similar
applications) - Examples of standardized systems
of fuses A to F
"Fuses for use by unskilled persons according to the following
fuse systems comply with all subclauses of IEC 60269-1 and
with the requirements laid down in the relevant fuse systems.
This standard is divided into six fuse systems, each dealing
with a specific example of standardized fuses for use by
unskilled persons."
IEC 60269-3 Ed. 3.0 b:2006 Low-voltage fuses - Part 3: Supplementary
requirements for fuses for use by unskilled
persons (fuses mainly for household and similar
applications) - Examples of standardized systems
of fuses A to F
"Fuses for use by unskilled persons according to the following
fuse systems comply with all subclauses of IEC 60269-1 and
with the requirements laid down in the relevant fuse systems.
This standard is divided into six fuse systems, each dealing
with a specific example of standardized fuses for use by
unskilled persons."
IEC 60269-4 Ed. 4.0 b:2006 Low-voltage fuses - Part 4: Supplementary
requirements for fuse-links for the protection of
semiconductor devices
"These supplementary requirements apply to fuse-links for
application in equipment containing semiconductor devices for
circuits of nominal voltages up to 1 000 V a.c. or 1 500 V d.c.
and also, in so far as they are applicable, for circuits of higher
nominal voltages."
IEC 60282-1 Ed. 6.0 b:2005 High-voltage fuses - Part 1: Current-limiting fuses This part of IEC 60282
applies to all types of high-voltage
current-limiting fuses designed for use outdoors or indoors on
alternating current systems of 50 Hz and 60 Hz and of rated
voltages exceeding 1000 V.
IEC 60282-2 Ed. 2.1 b:1997 High-voltage fuses - Part 2: Expulsion fuses "Specifies requirements for
expulsion fuses designed for use
outdoors or indoors on alternating current systems of 50 Hz
and 60 Hz, and of rated voltages exceeding 1 000 V. "
IEC 60549 Ed. 1.0 b:1976 High-voltage fuses for the external protection of
shunt power capacitors
Applies to external fuses used with high-voltage capacitors for
use on alternating current systems of 50 Hz and 60 Hz.
Formulates uniform requirements and test procedures
regarding performance and testing of fuses intended to be
used for capacitor protection. Lists information to be given to
the user.
IEC/TR 61818 Ed. 1.0 b:2003 Application guide for low-voltage fuses "This guide for low-voltage fuses
shows how current-limiting
fuses are easy to apply to protect today's complex and
sensitive electronic equipment. It specifically covers
low-voltage fuses up to a.c. 1 000 V and d.c. 1 500 V.
Provides information on the application of fuses which are not
always covered, as well as important facts which are
sometimes difficult to locate in standards."
IEC 60146-1-1 Ed. 3.0 b:1991 Semiconductor convertors - General requirements
and line commutated convertors - Part 1-1:
Specifications of basic requirements
Part 1-1: Specifications of basic requirements Specifies the
requirements for the performance of all electronic power
convertors and electronic power switches using controllable
and/or non-controllable electronic valves. Specifies the
requirements applicable to line commutated convertors for
conversion of a.c. power to d.c. power or vice versa including
tests and service conditions which influence the basis of rating.
IEC 60265-1 Ed. 3.0 b:1998 High-voltage switches - Part 1: Switches for rated
voltages above 1 kV and less than 52 kV
"Is applicable to three-phase, alternating current switches and
switch-disconnectors having making and breaking current
ratings, for indoor and outdoor installations, for rated voltages
above 1 kV and less than 52 kV and for rated frequencies from
16 2/3 Hz up to and including 60 Hz. This standard is also
applicable to the operating devices of these switches and to
their auxiliary equipment. "
IEC 60265-2 Amd.1 Ed. 1.0 b:1994 Amendment 1 - High-voltage switches. Part 2:
High-voltage switches for rated voltages of 52 kV
and above
IEC 60265-2 Amd.2 Ed. 1.0 b:1998 Amendment 2 - High-voltage switches. Part 2:
High-voltage switches for rated voltages of 52 kV
and above
IEC 60265-2 Ed. 1.0 b:1988 High-voltage switches. Part 2: High-voltage
switches for rated voltages of 52 kV and above
"Applicable to three-phase alternating-current switches, having
making and breaking current ratings, for indoor and outdoor
installations, for rated voltages 52 kV and above, and for rated
frequencies up to and including 60 Hz. "
IEC 60388-1 Ed. 1.0 b:1972 Thermal time delay switches for use in equipment
for telecommunications and in electronic
applications employing similar techniques. Part 1:
General requirements and measuring methods
Defines general requirements and measuring methods
applicable to thermal time delay switches for use in equipment
for telecommunication and in electronic applications employing
similar techniques.
IEC 60389-1 Amd.1 Ed. 1.0 b:1976 Amendment 1 - Thermostatic switches primarily
for use in equipment for telecommunications and
in electronic applications employing similar
techniques. Part 1: General requirements and
measuring methods
IEC 60389-1 Ed. 1.0 b:1972 Thermostatic switches primarily for use in
equipment for telecommunications and in
electronic applications employing similar
techniques. Part 1: General requirements and
measuring methods
"Establishes, for thermostatic switches, uniform requirements
for the electrical, thermal, climatic and mechanical properties
as well as safety aspects and test methods. "
IEC 60669-1 Amd.1 Ed. 3.0 b:1999 Amendment 1 - Switches for household and
similar fixed-electrical installations - Part 1:
General requirements
IEC 60669-1 Amd.2 Ed. 3.0 b:2006 Amendment 2 - Switches for household and
similar fixed-electrical installations - Part 1:
General requirements
IEC 60669-1 Ed. 3.1 b:2000 Switches for household and similar fixed-electrical
installations - Part 1: General requirements
"Applies to manually operated general purpose switches for
a.c. only, with a rated voltage not exceeding 440 V and a rated
current not exceeding 63 A. "
IEC 60669-2-1 Ed. 4.0 b:2002 Switches for household and similar fixed electrical
installations - Part 2-1: Particular requirements Electronic switches
Applies to electronic switches and to associated electronic
extension units for household and similar fixed electrical
installations either indoors or outdoors.
IEC 60669-2-2 Ed. 3.0 b:2006 Switches for household and similar fixed electrical
installations - Part 2-2: Particular requirements Electromagnetic remote-control switches (RCS)
"This part of IEC 60669 applies to electromagnetic
remote-control switches (hereinafter referred to as RCS) with a
rated voltage not exceeding 440 V and a rated current not
exceeding 63 A, intended for household and similar fixed
electrical installations, either indoors or outdoors."
IEC 60669-2-3 Ed. 3.0 b:2006 Switches for household and similar fixed electrical
installations - Part 2-3: Particular requirements Time-delay switches (TDS)
"This part of IEC 60669 applies to time-delay switches
(hereinafter referred to as TDS) with a rated voltage not
exceeding 440 V and a rated current not exceeding 63 A,
intended for household and similar fixed electrical installations,
either indoors or outdoors, operated by hand and/or by remote
control. "
IEC 60669-2-4 Ed. 1.0 b:2004 Switches for household and similar fixed electrical
installations - Part 2-4: Particular requirements Isolating switches
"This part of IEC 60669 applies to manually operated general
purpose isolating switches with a rated voltage not exceeding
440 V and a rated current not exceeding 125 A, intended for
household and similar fixed electrical installations, either
indoors or outdoors. "
IEC 61020-6-2 Ed. 1.0 b:1994 "Electromechanical switches for use in electronic
equipment - Part 6: Sectional specification for
sensitive switches - Section 2: Detail specification
for one pole, unsealed subminiature sensitive
switches, 250 V maximum, 5 A maximum electrical
rating"
IEC 61058-1 Amd.1 Ed. 3.0 b:2001 Amendment 1 - Switches for appliances - Part 1:
General requirements
IEC 61058-1 Ed. 3.1 b:2001 Switches for appliances - Part 1: General
requirements
"Applies to switches for appliances actuated by hand, by foot
or by other human activity for use in, on or with appliances and
other equipment for household and similar purposes, with a
rated voltage not exceeding 440 V and a rated current not
exceeding 63 A. Also covers the indirect actuation of the
switch when the function of the actuating member is provided
by a part of an appliance or equipment. Replaces IEC 60328
(1972)."
IEC 61058-2-1 Amd.1 Ed. 1.0 b:1995 Amendment 1 - Switches for appliances - Part 2-1:
Particular requirements for cord switches
IEC 61058-2-1 Ed. 1.0 b:1992 Switches for appliances - Part 2-1: Particular
requirements for cord switches
"Applies to cord switches for appliances actuated by hand, by
foot or by other human activity for use in, on or with appliances
and other equipment for household and similar purposes, with
a rated voltage not exceeding 250 V and a rated current not
exceeding 16 A. "
IEC 61058-2-4 Amd.1 Ed. 1.0 b:2003 Amendment 1 - Switches for appliances - Part 2-4:
Particular requirements for independently mounted
switches
IEC 61058-2-4 Ed. 1.1 b:2003 Switches for appliances - Part 2-4: Particular
requirements for independently mounted switches
"Applies to independently mounted switches for appliances
actuated by hand, by foot or by other human activity for use
with appliances and other equipment for household and similar
purposes, with a rated voltage not exceeding 440 V and a
rated current not exceeding 63 A."
IEC 61058-2-5 Ed. 1.0 b:1994 Switches for appliances - Part 2-5: Particular
requirements for change-over selectors
"Applies to change-over selectors for appliances actuated by
hand, by foot or by other human activity for use in, on, or with
appliances and other equipment for household and similar
purposes, with a rated voltage not exceeding 440 V and a
rated current not exceeding 63 A."
IEC 60050-446 Ed. 1.0 t:1983 International Electrotechnical Vocabulary.
Electrical relays
IEC 60255-11 Ed. 1.0 b:1979 Electrical relays - Part 11: Interruptions to and
alternating component (ripple) in d.c. auxiliary
energizing quantity of measuring relays
IEC 60255-12 Ed. 1.0 b:1980 Electrical relays - Part 12: Directional relays and
power relays with two input energizing quantities
Specifies performance requirements for the subfamily as
shown in the title. This publication forms part of a series
dealing with measuring relays with more than one input
energizing quantity and for which IEC 60255-6 gives the
general requirements.
IEC 60255-13 Ed. 1.0 b:1980 Electrical relays - Part 13: Biased (percentage)
differential relays
Specifies performance requirements for the subfamily. Forms
part of a series dealing with measuring relays with more than
one input energizing quantity and for which IEC 60255-6 gives
the general requirements.
IEC 60255-16 Ed. 1.0 b:1982 Electrical relays - Part 16: Impedance measuring
relays
Specifies the general requirements for impedance measuring
relays. Covers test methods and methods of presenting relay
characteristics and performance.
IEC 60255-21-1 Ed. 1.0 b:1988 "Electrical relays - Part 21: Vibration, shock, bump
and seismic tests on measuring relays and
protection equipment - Section One: Vibration
tests (sinusoidal)"
"This part includes two types of vibration tests: the vibration
response test and the vibration endurance test, and is
generally based upon IEC 68-2-6. The requirements are
applicable only to measuring relays and protection equipment
in a new condition. The tests specified are type tests. "
IEC 60255-21-2 Ed. 1.0 b:1988 "Electrical relays - Part 21: Vibration, shock, bump
and seismic tests on measuring relays and
protection equipment - Section Two: Shock and
bump tests"
"This standard includes two types of tests: -the shock test (on
energized and non-energized specimen), -the bump test (on
non-energized specimen). These requirements are applicable
only to measuring relays and protection equipment in a new
condition. "
IEC 60255-21-3 Ed. 1.0 b:1993 "Electrical relays - Part 21: Vibration, shock, bump
and seismic tests on measuring relays and
protection equipment - Section 3: Seismic tests"
"Specifies the vibration, shock, bump and seismic tests
applicable to electromechanical and static measuring relays
and protection equipment, with or without output contacts. "
IEC 60255-22-1 Ed. 2.0 b:2005 Electrical relays - Part 22-1: Electrical disturbance
tests for measuring relays and protection
equipment - 1 MHz burst immunity tests
"Specifies the general requirements for 1 MHz burst immunity
tests for measuring relays and protection equipment for power
system protection, including the control, monitoring and
process interface equipment used with those systems. Is to be
used in conjunction with IEC 61000-4-12."
IEC 60255-22-2 Ed. 2.0 b:1996 Electrical relays - Part 22: Electrical disturbance
tests for measuring relays and protection
equipment - Section 2: Electrostatic discharge
tests
Specifies general requirements for electrostatic discharge
tests of static measuring relays and protection equipment. Is
based on IEC 1000-4-2 and refers to that standard where
applicable.
IEC 60255-22-3 Ed. 2.0 b:2000 Electrical relays - Part 22-3: Electrical disturbance
tests for measuring relays and protection
equipment - Radiated electromagnetic field
disturbance tests
"Specifies the general requirements for radiated
electromagnetic field disturbance tests for measuring relays
and protection equipment for power system protection,
including the control, monitoring and process interface
equipment used with those systems. Is based on IEC
61000-4-3."
IEC 60255-22-4 Ed. 2.0 b:2002 Electrical relays - Part 22-4: Electrical disturbance
tests for measuring relays and protection
equipment - Electrical fast transient/burst
immunity test
"Specifies the general requirements for electrical fast transient
immunity tests for measuring relays and protection equipment
for power system protection, including the control, monitoring
and process interface equipment used with these systems. Is
based on IEC 61000-4-4. "
IEC 60255-22-5 Ed. 1.0 b:2002 Electrical relays - Part 22-5: Electrical disturbance
tests for measuring relays and protection
equipment - Surge immunity test
"Specifies the general requirements for surge tests for
measuring relays and protection equipment for power system
protection, including the control, monitoring and process
interface equipment used with these systems. Is based on IEC
61000-4-5."
IEC 60255-22-6 Ed. 1.0 b:2001 Electrical relays - Part 22-6: Electrical disturbance
tests for measuring relays and protection
equipment - Immunity to conducted disturbances
induced by radio frequency fields
"Specifies the general requirements for conducted
disturbances induced by electromagnetic fields for measuring
relays and protection equipment for power system protection,
including the control, monitoring and process interface
equipment used with those systems."
IEC 60255-22-7 Ed. 1.0 b:2003 Electrical relays - Part 22-7: Electrical disturbance
tests for measuring relays and protection
equipment - Power frequency immunity tests
"Specifies general requirements for power frequency immunity
tests for measuring relays and protection equipment for power
system protection, including the control, monitoring and
process interface equipment used with those systems. The
objective of the tests is to confirm that the equipment under
test will operate correctly when energised and subjected to
short duration, conducted, common and differential mode
power frequency disturbances. Is based on IEC 61000-4-16."
IEC 60255-24 Ed. 1.0 b:2001 Electrical relays - Part 24: Common format for
transient data exchange (COMTRADE) for power
systems
Defines a format for files containing transient waveform and
event data collected from power systems or power system
models. Applies to files stored on physical media such as
digital hard drives and diskettes.
IEC 60255-25 Ed. 1.0 b:2000 Electrical relays - Part 25: Electromagnetic
emission tests for measuring relays and protection
equipment
"Specifies the general requirements for the measurement of
radio-frequency emissions emanating from measuring relays
and protection equipment for power system protection,
including the control, monitoring and process interface
equipment used with such systems. Is based on CISPR 22."
IEC 60255-26 Ed. 1.0 b:2004 Electrical relays - Part 26: Electromagnetic
compatibility requirements for measuring relays
and protection equipment
"Specifies the requirements for electromagnetic compatibility
for measuring relays and protection equipment. Is applicable to
measuring relays and protection equipment for power system
protection, including the control, monitoring and process
interface equipment used with those systems."
IEC 60255-3 Ed. 2.0 b:1989 Electrical relays - Part 3: Single input energizing
quantity measuring relays with dependent or
independent time
Definitions. Standard values relating to energizing quantities
influencing quantities. Fundamental characteristics relating to
temperature rises and behaviour in service. Accuracy
requirements relating to the characteristic quantity and
specified times. Mechanical and electrical requirements.
Markings and data. Methods of measurement.
IEC 60255-5 Ed. 2.0 b:2000 Electrical Relays - Part 5: Insulation coordination
for measuring relays and protection equipment Requirements and tests
Lays down general requirements for the insulation coordination
of measuring relays and protection equipment. Gives guidance
for the selection of clearances and creepage distances and
other aspects related to the insulation of measuring relays and
protection equipment; specifies requirements for voltage tests
and insulation resistance measurement.
IEC 60255-6 Ed. 2.0 b:1988 Electrical relays - Part 6: Measuring relays and
protection equipment
This standard specifies the general performance requirements
of all electrical measuring relays and protection equipment
used in the electrotechnical fields covered by the IEC.
Supersedes IEC 60255-6 (1978) and its first supplement
60255-6 A (1980).
IEC 60255-8 Ed. 2.0 b:1990 Electrical relays - Part 8: Thermal electrical relays This edition supersedes the
first edition of IEC 60255-8 (1978)
and IEC 60255-17 (1982). Applies to dependent specified time
electrical measuring relays which protect equipment from
electrical thermal damage by the measurement of current
flowing in protected equipment. States the particular
requirements for thermal electrical relays. Is to be read in
conjunction with higher level documents in the IEC 60255
series.
IEC 60309-1 Amd.1 Ed. 4.0 b:2005 "Amendment 1 - Plugs, socket-outlets and
couplers for industrial purposes - Part 1: General
requirements "
IEC 60309-1 Ed. 4.1 b:2005 "Plugs, socket-outlets and couplers for industrial
purposes - Part 1: General requirements"
"This standard applies to plugs and socket-outlets, cable
couplers and appliance couplers, with a rated operating
voltage not exceeding 690 V d.c. or a.c. and 500 Hz a.c., and
a rated current not exceeding 250 A, primarily intended for
industrial use, either indoors or outdoors."
IEC 60309-2 Amd.1 Ed. 4.0 b:2005 "Amendment 1 - Plugs, socket-outlets and
couplers for industrial purposes - Part 2:
Dimensional interchangeability requirements for
pin and contact-tube accessories "
IEC 60309-2 Ed. 4.1 b:2005 "Plugs, socket-outlets and couplers for industrial
purposes - Part 2: Dimensional interchangeability
requirements for pin and contact-tube
accessories"
"This standard applies to plugs and socket-outlets, cable
couplers and appliance couplers with a rated operating voltage
not exceeding 690 V, 500 Hz and a rated current not
exceeding 125 A, primarily intended for industrial use, either
indoors or outdoors. "
IEC 60309-4 Ed. 1.0 b:2006 "Plugs, socket-outlets and couplers for industrial
purposes - Part 4: Switched socket-outlets and
connectors with or without interlock "
"This part of IEC 60309 applies to self-contained products that
combine within a single enclosure, a socket-outlet or connector
according to IEC 60309-1 or IEC 60309-2 and a switching
device, with a rated operating voltage not exceeding 690 V d.c.
or a.c. and 500 Hz , and a rated current not exceeding 250 A,
primarily intended for industrial use, either indoors or
outdoors."
IEC 60884-1 Amd.1 Ed. 3.0 b:2006 Amendment 1 - Plugs and socket-outlets for
household and similar purposes - Part 1: General
requirements
IEC 60884-1 Ed. 3.1 b:2006 Plugs and socket-outlets for household and similar
purposes - Part 1: General requirements
"This part of IEC 60884 applies to plugs and fixed or portable
socket-outlets for a.c. only, with or without earthing contact,
with a rated voltage greater than 50 V but not exceeding 440 V
and a rated current not exceeding 32 A, intended for
household and similar purposes, either indoors or outdoors."
IEC 60884-2-1 Ed. 2.0 b:2006 Plugs and socket-outlets for household and similar
purposes - Part 2-1: Particular requirements for
fused plugs
"This part of IEC 60884 applies to fused plugs, where the
fuses are primarily intended to protect the flexible cable or
cord. These fuses are not intended to protect appliances or
parts of them against overload. "
IEC 60884-2-2 Ed. 2.0 b:2006 Plugs and socket-outlets for household and similar
purposes - Part 2-2: Particular requirements for
socket-outlets for appliances
"This part of IEC 60884 applies to socket-outlets for a.c. only,
with or without earthing contact, with a rated voltage not
exceeding 250 V and a rated current not exceeding 16 A,
which are integrated or intended to be incorporated in or fixed
to appliances, hereafter referred to as socket-outlets for
appliances."
IEC 60884-2-3 Ed. 2.0 b:2006 Plugs and socket-outlets for household and similar
purposes - Part 2-3: Particular requirements for
switched socket-outlets without interlock for fixed
installations
"This part of IEC 60884 applies to switched socket-outlets
without interlock, for fixed installation, for a.c. only, with or
without earthing contact, with a rated voltage not exceeding
440 V and a rated current not exceeding 32A, intended for
household and similar purposes, either indoors or outdoors."
IEC 60884-2-4 Ed. 2.0 b:1999 Plugs and socket-outlets for household and similar
purposes - Part 2-4: Particular requirements for
plugs and socket-outlets for SELV
"Applies to plugs, fixed or portable socket-outlets, and to
socket-outlets for appliances with d.c. or a.c. (50/60 Hz) SELV
with rated current of 16 A. "
IEC 60884-2-5 Ed. 1.0 b:1995 Plugs and socket-outlets for household and similar
purposes - Part 2: Particular requirements for
adaptors
"This standard applies to shuttered and non-shuttered, fused
and non-fused adaptors for a.c. only. "
IEC 60884-2-6 Ed. 1.0 b:1997 Plugs and socket-outlets for household and similar
purposes - Part 2-6: Particular requirements for
switched socket-outlets with interlock for fixed
electrical installations
"Applies to switched socket-outlets with interlock for a.c. only,
for fixed electrical installations, with or without earthing
contact, with rated voltage above 50 V but not exceeding 440
V and a rated current not exceeding 32 A, intended for
household and similar purposes, either indoors or outdoors."
IEC 60906-1 Ed. 1.0 b:1986 IEC system of plugs and socket-outlets for
household and similar purposes - Part 1: Plugs
and socket-outlets 16 A 250 V a.c.
"Applies to the IEC System of plugs and socket-outlets rated
16 A 250 V a.c. for household and similar purposes for the
connection of equipment to distribution systems having
nominal voltages between 200 V and 250 V a.c., in so far as
dimensional requirements are concerned. The object of this
part is to provide a standard for a safe, compact and practical
IEC 250 V system of plugs and socket-outlets that could be
accepted by many countries as their national standard, now or
in in the near future. It is therefore recommended that any
country in need of a new or replacement system for the
nominal voltage range 200 V to 250 V a.c. adopt this standard
as its only national standard. "
IEC 60906-2 Ed. 2.0 b:1997 IEC system of plugs and socket-outlets for
household and similar purposes - Part 2: Plugs
and socket-outlets 15 A 125 V a.c.
"Applies to the IEC system of plugs and socket-outlets rated
15 A 125 V a.c. for household and similar purposes for the
connection of equipment to distribution systems having
nominal voltages between 100 V and 125 V a.c. in so far as
dimensional requirements are concerned. The object of this
part is to provide a standard for a safe, compact and practical
IEC 125 V system of plugs and socket-outlets that could be
accepted by many countries as their national standard, now or
in in the near future. It is therefore recommended that any
country in need of a new or replacement system for the
nominal voltage range 100 V to 125 V a.c. adopt this standard
as its only national standard."
IEC 60906-3 Ed. 1.0 b:1994 "IEC System of plugs and socket-outlets for
household and similar purposes - Part 3: SELV
plugs and socket-outlets, 16 A 6V, 12 V, 24 V, 48
V, a.c. and d.c."
"Applies to the IEC SELV System of plugs, fixed and portable
socket-outlets and to socket-outlets for appliances rated 16 A
6 V, 12 V, 24V, 48 V a.c. and d.c., intended for household and
similar purposes, either indoors or outdoors."
IEC 62196-1 Ed. 1.0 b:2004 "Plugs, socket-outlets, vehicle couplers and
vehicle inlets - Conductive charging of electric
vehicles - Part 1: Charging of electric vehicles up
to 250 A a.c. and 400 A d.c."
"This part of IEC 62196 is applicable to plugs, socket-outlets,
connectors, inlets and cable assemblies for electric vehicles,
intended for use in conductive charging systems which
incorporate control means, with a rated operating voltage not
exceeding: 690 V a.c., 50 - 60 Hz, at a rated current not
exceeding 250 A; 600 V d.c., at a rated current not exceeding
400 A. "
IEC/TR 60083 Ed. 5.0 b:2006 Plugs and socket-outlets for domestic and similar
general use standardized in member countries of
IEC
"The object of this technical report is to give general
information about the systems of plugs and socket-outlets for
household and similar purposes which are used in the IEC
countries. The report only contains National Systems which
are commonly used in homes and offices. It is therefore limited
to systems for a.c. with a rated voltage above 50 V but not
exceeding 440 V, intended for household and similar
purposes, either indoors or outdoors. The report only contains
systems for which standard sheets have been published in a
National Standard, which may be a National Standard of the
country itself or any other IEC member country"
IECEE CEE-7 Ed. 2.0 b:1963 Specification for plugs and socket-outlets for
domestic and similar purpose
"This CEE 7 publication originally published as the 2nd edition
on 1963-05 also contains Modification 1 (1973-08),
Modification 2 (1974-06), Modification 3 (1975-09) and
Modification 4 (1983-03). Please note that this standard shall
not be used alone, it is to be used in addition to IEC 60884-1."