• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Apprentice Electrical Technician Test (ETT) Preparation Guide
Apprentice Electrical Technician Test (ETT) Preparation Guide

... APPRENTICE ELECTRICAL TECHNICIAN TEST (ETT) About the Test There are 40 questions with a maximum time limit of three hours. This is a closed book test and calculators are allowed. Seventy percent (70%) score is required to qualify. Reference Materials ETT test contains questions on the following: ...
Document
Document

2012 42 Spring Wiring Matters
2012 42 Spring Wiring Matters

Annex A (IEEE_1246).
Annex A (IEEE_1246).

tender specifications
tender specifications

... This module represents basic concepts of the Electric Energy high-voltage three-phase transmission lines operation. It simulates a value modifying concentrated parameter line that allows different configurations and consists on three conductor line (R, S, T) and a Neutral or return line (N). Each of ...
Lab 4 Common Base Characteristics of a BJT Transistor
Lab 4 Common Base Characteristics of a BJT Transistor

... (VPS+) for VCC and External Negative Power Supply for VEE. For current measurement, use the External Multimeter provided. ...
Technical Research Paper “Microcontroller based Fault Detector”
Technical Research Paper “Microcontroller based Fault Detector”

SubMonitor Spec Sheet
SubMonitor Spec Sheet

Datasheet - Technobots
Datasheet - Technobots

21.1 Magnets & Magnetic Fields
21.1 Magnets & Magnetic Fields

...  So if you move a magnet near a conductor electric current is generated ...
current = potential difference resistance •1. Find the unknown
current = potential difference resistance •1. Find the unknown

... 15. (a) Draw a circuit with a 10 kO resistor, a cell(battery), an ammeter, and a switch all in series. (b) If the ammeter reads 155 mA what is the potential difference across the cell (battery). ...
DATA SHEET G.1.56.80/12/90°iso
DATA SHEET G.1.56.80/12/90°iso

... Wiring materials are components for the wiring of residual current circuit-breakers, residual current operated and miniature circuitbreakers and D0 switch-disconnectors in industrial, commercial and privately use electrical distribution units. They considerably reduce the installation work. Covers a ...
Ohm`s Law Practice Worksheet Answer Key
Ohm`s Law Practice Worksheet Answer Key

09. Electricity Notes
09. Electricity Notes

R225-60-9
R225-60-9

... the resistive component is available for the control to maintain correct voltage at the load center. If the resistive component is to be used while the negative reactance method of paralleling is used, the resistive settings of all of the regulators being paralleled should be set to the same value. ...
Model Answer
Model Answer

... a) If it is a high-impedance voltmeter. b) If it is a very low impedance ammeter. Solved exactly in lectures; a) Replace the high impedance voltmeter with open circuit b) Replace the very low impedance ammeter with short circuit Write the mesh current equations to find the three line currents then f ...
INTRODUCTION TO OHM`S LAW
INTRODUCTION TO OHM`S LAW

... Ohms law can also be applied in AC circuits.But alternating voltage and currents are always changing. From zero, current and voltage builds up and reach its max peak in the positive value at 90 degrees and then back to zero and again to the negative peak value. In this regard, Its only possible to c ...
How to do the wiring of XM 300C, XD 312:
How to do the wiring of XM 300C, XD 312:

Ohm`s Law Practice Problems (part of 1.2.3) The relationship
Ohm`s Law Practice Problems (part of 1.2.3) The relationship

... The relationship between current, voltage, and resistance within an electrical circuit was developed by Georg Simon Ohm and is known today as Ohm’s law. Ohm’s law states that the direct current flowing in an electric circuit is directly proportional to the voltage applied to the circuit. In other wo ...
Grounding Probe
Grounding Probe

... The Aqua One Grounding Probe will also ground any leaking current resulting from damaged submersed electrical devices. When connected to a power outlet with a safety switch (GFCI or RCD), the grounding probe will trip the circuit if stray current enters the aquarium, eliminating the potentially harm ...
Circuits
Circuits

... be lowered to just 100 Ω, increasing current dramatically • Current in Amps Effect ...
what is that hanging on the pole?
what is that hanging on the pole?

... Regulators maintain the voltage depending on customer demand for electricity. ...
E E 2440 Circuits I
E E 2440 Circuits I

Evolis 24 kV Lateral version
Evolis 24 kV Lateral version

... b IEC 62271-100: high voltage AC circuit breaker b IEC 62271-200 (previously IEC 60298): AC metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV. ...
Unit of Instruction: Electricity
Unit of Instruction: Electricity

... Unit Map ____________________________________________________________________________________________________________ Unit of Instruction: Electricity Learning Target ...
< 1 ... 320 321 322 323 324 325 326 327 328 ... 353 >

Earthing system

In electricity supply systems, an earthing system or grounding system is circuitry which connects parts of the electric circuit with the ground, thus defining the electric potential of the conductors relative to the Earth's conductive surface. The choice of earthing system can affect the safety and electromagnetic compatibility of the power supply. In particular, it affects the magnitude and distribution of short circuit currents through the system, and the effects it creates on equipment and people in the proximity of the circuit. If a fault within an electrical device connects a live supply conductor to an exposed conductive surface, anyone touching it while electrically connected to the earth will complete a circuit back to the earthed supply conductor and receive an electric shock.A protective earth (PE), known as an equipment grounding conductor in the US National Electrical Code, avoids this hazard by keeping the exposed conductive surfaces of a device at earth potential. To avoid possible voltage drop no current is allowed to flow in this conductor under normal circumstances. In the event of a fault, currents will flow that should trip or blow the fuse or circuit breaker protecting the circuit. A high impedance line-to-ground fault insufficient to trip the overcurrent protection may still trip a residual-current device (ground fault circuit interrupter or GFCI in North America) if one is present. This disconnection in the event of a dangerous condition before someone receives a shock, is a fundamental tenet of modern wiring practice and in many documents is referred to as automatic disconnection of supply (ADS). The alternative is defence in depth, where multiple independent failures must occur to expose a dangerous condition - reinforced or double insulation come into this latter category.In contrast, a functional earth connection serves a purpose other than shock protection, and may normally carry current. The most important example of a functional earth is the neutral in an electrical supply system. It is a current-carrying conductor connected to earth, often, but not always, at only one point to avoid flow of currents through the earth. The NEC calls it a groundED supply conductor to distinguish it from the equipment groundING conductor. Other examples of devices that use functional earth connections include surge suppressors and electromagnetic interference filters, certain antennas and measurement instruments.Regulations for earthing system vary considerably among countries and among different parts of electric systems. Most low voltage systems connect one supply conductor to the earth (ground).People use an earthing system mainly for these applications: To protect a structure from lightning strike, directing the lightning through the earthing system and into the ground rod rather than passing through the structure. Part of the safety system of mains electricity, preventing problems associated with floating ground and sky voltage. The most common ground plane for large monopole antenna and some other kinds of radio antenna.Other, less common applications of earthing systems include: single-wire earth return. part of a system that powers small devices from sky voltage. one at each end of a ground dipole ELF antenna.