• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Slajd 1
Slajd 1

File
File

... A clothes dryer in a home has a power of 4,500 watts and runs on a special 220-volt household circuit. a. What is the current through the dryer? b. What is the resistance of the dryer? c. How many kilowatt-hours of electricity are used by the dryer if it is used for 4 hours in one week? d. How much ...
intro to electrical safety pt 2
intro to electrical safety pt 2

... to evolve exponentially, but the standards for safe design and routine safety verification lagged behind the need. In the four decades since then, medical devices that diagnose and treat disease, or assist with treatment have advanced dramatically in complexity and number, and standards have been wr ...
Student Handout #2 Extract - AS 440-221, Safe Laboratory
Student Handout #2 Extract - AS 440-221, Safe Laboratory

... body is insulated from the ground. The skin offers about the only resistance presented by the human body to the flow of current. When the skin is dry, it may present from 100,000 to as much as 600,000 ohms resistance, depending upon its thickness (0.015 to 0.025 inches) and on other personal factors ...
Chapter 19: Electric Charges and Currents
Chapter 19: Electric Charges and Currents

... charge, moving charge operate gauge (also in ovens and gas furnaces) ...
University of Bejaia 2nd year Technology Lecture two: Electric circuit
University of Bejaia 2nd year Technology Lecture two: Electric circuit

Understanding the Differences Between Bonding, Grounding, and
Understanding the Differences Between Bonding, Grounding, and

series rated combinations
series rated combinations

... (a) electrical equipment required to interrupt fault currents shall have ratings sufficient for the voltage employed and for the fault current that is available at the terminals; and (b) electrical equipment required to interrupt current at other than fault levels shall have ratings sufficient for t ...
2008 26 Spring Wiring Matters
2008 26 Spring Wiring Matters

... circuit are liable to come into contact, either intentionally or fortuitously with the exposed-conductive-parts of other circuits, protection against electric shock no longer depends solely on protection by electrical separation but on the protective provisions to which the latter exposedconductive- ...
Grounding and Bonding in Boats and Marinas
Grounding and Bonding in Boats and Marinas

... to prevent personal injury and fire. Since it’s not a perfect world, we must accept some of the corrosion-related concerns that stem from providing for a safe marine environment. Accepting this, there are many options out there for addressing these concerns to protect a boat from underwater corrosio ...
Grounding and Bonding in Boats and Marinas
Grounding and Bonding in Boats and Marinas

Introduction
Introduction

Reigh Walling Commen.. - pes-psrc
Reigh Walling Commen.. - pes-psrc

... Z1L1=R1L1+jX1L1 Z0L1=R0L1+jX0L1 Z1L2=R1L2+jX1L2 Z0L2=R0L2+jX0L2 Impedances from the wind farm to the point of interconnection are provided by the project proponent. If prefault power flow conditions are important to the fault study, these shall be provided to the project proponent. In addition to th ...
Document
Document

Basic Circuits Notes
Basic Circuits Notes

... Voltmeter – meter used to measure the voltage (the change in electric potential from one side of a resistor to the other or from one place in a circuit to another place in the circuit). Because you are measuring the difference in electric potential between two locations (even if it is just from ...
Problem 1 Find out how much power the 2 A source delivers to the
Problem 1 Find out how much power the 2 A source delivers to the

...   ELEC 300 — Linear Circuits: II — Spring 2017  ...
(a) (i) Define electromotive force (emf ) of a battery. (1 mark) (ii
(a) (i) Define electromotive force (emf ) of a battery. (1 mark) (ii

Electric Circuits
Electric Circuits

Photovoltaic Checklist
Photovoltaic Checklist

I PN = 200 A Current Transducer LA 200-P
I PN = 200 A Current Transducer LA 200-P

WORK EDUCATION PROJECT
WORK EDUCATION PROJECT

EM_Jeopardy
EM_Jeopardy

... charged objects. ...
CN-0009 利用AD5662 DAC实现4 mA至20 mA过程控制环路
CN-0009 利用AD5662 DAC实现4 mA至20 mA过程控制环路

... 5 V reference, and the circuit requires no external trims because of the tight initial output voltage tolerance of the ADR02 and the low supply current of both the AD8627 and the AD5662. The limits on the allowable loop power supply are set by the ADR02 minimum input voltage (7 V) and maximum input ...
KRIWAN presents new solutions for current and
KRIWAN presents new solutions for current and

... About KRIWAN Industrie-Elektronik GmbH & Kriwan Americas KRIWAN has specialized in protecting industrial machines and systems from overload and downtime for nearly 50 years. Today, KRIWAN is the world market leader in electronics and sensor technology for refrigerant compressors, temperature sensor ...
Advanced VLSI Design - Washington State University
Advanced VLSI Design - Washington State University

... • In active mode, low-VT MOSFET’s achieve high speed. • In standby mode when St'by signal is high, high-VT MOSFET’s in series to normal logic circuits cut off leakage current. ...
< 1 ... 319 320 321 322 323 324 325 326 327 ... 353 >

Earthing system

In electricity supply systems, an earthing system or grounding system is circuitry which connects parts of the electric circuit with the ground, thus defining the electric potential of the conductors relative to the Earth's conductive surface. The choice of earthing system can affect the safety and electromagnetic compatibility of the power supply. In particular, it affects the magnitude and distribution of short circuit currents through the system, and the effects it creates on equipment and people in the proximity of the circuit. If a fault within an electrical device connects a live supply conductor to an exposed conductive surface, anyone touching it while electrically connected to the earth will complete a circuit back to the earthed supply conductor and receive an electric shock.A protective earth (PE), known as an equipment grounding conductor in the US National Electrical Code, avoids this hazard by keeping the exposed conductive surfaces of a device at earth potential. To avoid possible voltage drop no current is allowed to flow in this conductor under normal circumstances. In the event of a fault, currents will flow that should trip or blow the fuse or circuit breaker protecting the circuit. A high impedance line-to-ground fault insufficient to trip the overcurrent protection may still trip a residual-current device (ground fault circuit interrupter or GFCI in North America) if one is present. This disconnection in the event of a dangerous condition before someone receives a shock, is a fundamental tenet of modern wiring practice and in many documents is referred to as automatic disconnection of supply (ADS). The alternative is defence in depth, where multiple independent failures must occur to expose a dangerous condition - reinforced or double insulation come into this latter category.In contrast, a functional earth connection serves a purpose other than shock protection, and may normally carry current. The most important example of a functional earth is the neutral in an electrical supply system. It is a current-carrying conductor connected to earth, often, but not always, at only one point to avoid flow of currents through the earth. The NEC calls it a groundED supply conductor to distinguish it from the equipment groundING conductor. Other examples of devices that use functional earth connections include surge suppressors and electromagnetic interference filters, certain antennas and measurement instruments.Regulations for earthing system vary considerably among countries and among different parts of electric systems. Most low voltage systems connect one supply conductor to the earth (ground).People use an earthing system mainly for these applications: To protect a structure from lightning strike, directing the lightning through the earthing system and into the ground rod rather than passing through the structure. Part of the safety system of mains electricity, preventing problems associated with floating ground and sky voltage. The most common ground plane for large monopole antenna and some other kinds of radio antenna.Other, less common applications of earthing systems include: single-wire earth return. part of a system that powers small devices from sky voltage. one at each end of a ground dipole ELF antenna.