• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
06-Grounding 2003 pre
06-Grounding 2003 pre

Tutorial 4 (Chapter 20: Electric Circuits (Part 2)) Questions
Tutorial 4 (Chapter 20: Electric Circuits (Part 2)) Questions

Do now! - MrSimonPorter
Do now! - MrSimonPorter

... Circuit 2 is now switched on. Circuit 2 may have a large current flowing through it to operate a powerful motor or very bright lights. When the switch is opened the electromagnet releases the rocker arm and the spring moves the contacts apart. Circuit 2 is now switched off. ...
File
File

... In order to roll, a ball must be moving from “high ground” to “low ground”! Ball must move from high potential to low potential!!! ...
Blue Laser Diode NDB7875
Blue Laser Diode NDB7875

... Nichia LDs described in this brochure are intended to be used for ordinary electronic equipment (such as office equipment, communications equipment, measurement instruments and household appliances). Consult Nichia’s sales staff in advance for information on the applications in which exceptional qua ...
PSpiceAssignments1
PSpiceAssignments1

intro to circuits and ohms law
intro to circuits and ohms law

... Electrical The amountPotential of work that can be done by some charge moving in a circuit. Work electrical potential  charge ...
PAT testing of equipment with high leakage current
PAT testing of equipment with high leakage current

... testing equipment must be performed on an annual basis. However the IEE gives guidance in its publication the ‘Code of Practice for In-service Inspection and Testing of Electrical Equipment’ that a system of maintenance including performing such testing on a routine basis may achieve compliance with ...
Transformers
Transformers

... lot of electrical energy while a lamp requires very little. Some devices require different voltages and currents. A computer may require 12 V to operate, so the voltage in your home must be lowered from 120 V to 12 V. Transformers are electromagnetic devices that are used to lower or raise the AC vo ...
Healthcare Isolation Power Systems
Healthcare Isolation Power Systems

Unit 5 Basic Electrical and wiring
Unit 5 Basic Electrical and wiring

... panel. From the panel, the power is distributed to the different circuits throughout the house. ...
LA125-P - RGB Automatyka
LA125-P - RGB Automatyka

ppt - Physics Rocks!
ppt - Physics Rocks!

Chapter 25 Homework - Handout
Chapter 25 Homework - Handout

... - what 2 parameters are equal to each other (in opposite directions)? - as a result of this, does the total impedance go up, down or stay the same at fo? - will the circuit be an RL, RC, or purely L, C, or R circuit? - what will the circuit phase angle equal? - what is the power factor of a series r ...
SANYO Electric Co.,Ltd. Semiconductor Bussiness Headquarters
SANYO Electric Co.,Ltd. Semiconductor Bussiness Headquarters

CN-0098 利用AD5420提供16位、4 mA至20 mA输出简化解决方案
CN-0098 利用AD5420提供16位、4 mA至20 mA输出简化解决方案

... AD5420, a single channel, 16-bit, serial input, 4 mA-to-20 mA current source DAC. This circuit utilizes only the AD5420 product. The only external components needed are decoupling capacitors on the supply pins and reference input and a pull-up resistor for the open-drain FAULT output, which alerts t ...
Reducing high frequency ground currents to zero
Reducing high frequency ground currents to zero

... now virtually useless since PVC is not a conductor. Bonds, where two different types of metal join, corrode. Aged grounds can and will corrode over time. Some cities have already moved to correct these problems. This grounding system specifically targets applications in which three-phase and single ...
TP_101.01_Short Circuit impedance with Midas_1110
TP_101.01_Short Circuit impedance with Midas_1110

Chapter 19 Review Current and Resistance
Chapter 19 Review Current and Resistance

... transmitted over a time of 20 seconds. What is the current over this period? ...
are conductors (metals). Insulators (rubber,
are conductors (metals). Insulators (rubber,

... and closed in describing electrical circuits. ...
Electricity and Circuits Notes
Electricity and Circuits Notes

... Electricity and Circuits Notes Electric Charges What are the three subatomic particles and what are their charges? ...
Ch 10
Ch 10

... Resistance – the ability to impede the flow of electrons in conductors Ohms – the SI unit for electrical resistance; Ω V=IxR Voltage drop = Current x Resistance V=AxΩ Short Circuit – Positive and negative terminal of a dry cell are connected with no load to use the energy as the electrons become mor ...
study guide key
study guide key

... 18. A neutral metal object is touched by a negatively charged object. Where do the electrons travel to and what will the charge of the metal object be? ...
Circuit Breakers - Short Time Delay (STD)
Circuit Breakers - Short Time Delay (STD)

... is to provide protection to circuit components and equipment. A short-time delay (STD) setting on a circuit breaker can negate the function of protecting the circuit components. A low voltage power circuit breaker with a short-time delay and without instantaneous trip, permits a fault to flow for th ...
4. Fault Indicators Fault Indicators
4. Fault Indicators Fault Indicators

... transients during the initiation of the fault are used to detect the direction to the fault in compensated and isolated networks. • Peterson coil acts as high impedance to the transients, making the transients intact, not affected. • E (~voltage) • B (~Current) ...
< 1 ... 316 317 318 319 320 321 322 323 324 ... 353 >

Earthing system

In electricity supply systems, an earthing system or grounding system is circuitry which connects parts of the electric circuit with the ground, thus defining the electric potential of the conductors relative to the Earth's conductive surface. The choice of earthing system can affect the safety and electromagnetic compatibility of the power supply. In particular, it affects the magnitude and distribution of short circuit currents through the system, and the effects it creates on equipment and people in the proximity of the circuit. If a fault within an electrical device connects a live supply conductor to an exposed conductive surface, anyone touching it while electrically connected to the earth will complete a circuit back to the earthed supply conductor and receive an electric shock.A protective earth (PE), known as an equipment grounding conductor in the US National Electrical Code, avoids this hazard by keeping the exposed conductive surfaces of a device at earth potential. To avoid possible voltage drop no current is allowed to flow in this conductor under normal circumstances. In the event of a fault, currents will flow that should trip or blow the fuse or circuit breaker protecting the circuit. A high impedance line-to-ground fault insufficient to trip the overcurrent protection may still trip a residual-current device (ground fault circuit interrupter or GFCI in North America) if one is present. This disconnection in the event of a dangerous condition before someone receives a shock, is a fundamental tenet of modern wiring practice and in many documents is referred to as automatic disconnection of supply (ADS). The alternative is defence in depth, where multiple independent failures must occur to expose a dangerous condition - reinforced or double insulation come into this latter category.In contrast, a functional earth connection serves a purpose other than shock protection, and may normally carry current. The most important example of a functional earth is the neutral in an electrical supply system. It is a current-carrying conductor connected to earth, often, but not always, at only one point to avoid flow of currents through the earth. The NEC calls it a groundED supply conductor to distinguish it from the equipment groundING conductor. Other examples of devices that use functional earth connections include surge suppressors and electromagnetic interference filters, certain antennas and measurement instruments.Regulations for earthing system vary considerably among countries and among different parts of electric systems. Most low voltage systems connect one supply conductor to the earth (ground).People use an earthing system mainly for these applications: To protect a structure from lightning strike, directing the lightning through the earthing system and into the ground rod rather than passing through the structure. Part of the safety system of mains electricity, preventing problems associated with floating ground and sky voltage. The most common ground plane for large monopole antenna and some other kinds of radio antenna.Other, less common applications of earthing systems include: single-wire earth return. part of a system that powers small devices from sky voltage. one at each end of a ground dipole ELF antenna.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report