• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Times-Protect Brochure
Times-Protect Brochure

... When lightning strikes the tower, the shield and center conductor at the antenna are simultaneously elevated in potential. Since there is more surface area on the shield, the propagation velocity will be faster, and high frequencies will not be as attenuated as on the slower propagating center condu ...
OTB1C0DM9LP - Schneider Electric
OTB1C0DM9LP - Schneider Electric

... I/O distributed module OTB - CANopen bus 0..1000 m ...
Earth Resistance and Resistivity Tester
Earth Resistance and Resistivity Tester

Industrial Power System Design in a Utility Environment
Industrial Power System Design in a Utility Environment

... the geographic diversity of the loads, would make volt- requirements. Another concern is storm and ice damage. Central age drop and loss on medium- or low-voltage service Oklahoma has the most extreme meteorological condiunacceptably high. The total connected load is approximately 20 MW. The tions i ...
Man-1128
Man-1128

... The mains wiring should be as short as is practical with no excess lengths or larger loops and be separated from all extra low voltage wiring such as 24V supply wiring and battery leads. Ensure that all wires are fitted into the terminals without any exposed lengths or strands which may give rise to ...
Protection of Control Circuit Transformers for applications in North
Protection of Control Circuit Transformers for applications in North

Study paper on Lightning and surge protection in Telecom Networks
Study paper on Lightning and surge protection in Telecom Networks

... have a relatively low energy absorbing capability. Voltages can be clamped to less than twice the normal operation voltage. If current impulses remain within the device ratings, life expectancy is exceptionally long. If component ratings are exceeded, the diode may fail as a permanent short circuit; ...
Guide to Low Voltage Circuit-Breakers Standards
Guide to Low Voltage Circuit-Breakers Standards

... characteristics of low voltage circuit-breakers for use in industrial and household and similar installations, which fall within the wide scope of BEAMA’s Industrial & Single Phase Product Group. BEAMA’s Industrial & Single Phase Product Group comprises major UK manufacturing companies in this field ...
The History of Electricity
The History of Electricity

An auto-scaling wide dynamic range current to frequency converter
An auto-scaling wide dynamic range current to frequency converter

RIS P01 insulation status relay - ZAM
RIS P01 insulation status relay - ZAM

The Fundamentals of Three-Phase Power Measurements
The Fundamentals of Three-Phase Power Measurements

Laws of Magnetism Magnetic forces Magnetic deflection of electrons
Laws of Magnetism Magnetic forces Magnetic deflection of electrons

Alternating current
Alternating current

... Review ...
24DC/URD3/4X1/2X2/3
24DC/URD3/4X1/2X2/3

... For PSR applications, only yellow PSR-TBUS connectors (Order No. 2890425) may be used. Connection with another T-BUS is not permitted. Devices may only be mounted on/removed from the T-BUS when the power is switched off. A T-BUS unit can contain a basic device (PSR-...-SDC...) and a maximum of 10 ex ...
STK554U3xx Series Application Note
STK554U3xx Series Application Note

Power Supply, DMM, Breadboard, and Multisim
Power Supply, DMM, Breadboard, and Multisim

... The Display Limit button allows you to set a specific voltage or current limit. o This feature is especially important for limiting the maximum current output from the power supply. The current limit should always be set at or below 100mA for safety. ...
MAX4789–MAX4794 200mA/250mA/300mA Current
MAX4789–MAX4794 200mA/250mA/300mA Current

SERIES AND PARALLEL CONNECTED DIODES Series Configuration
SERIES AND PARALLEL CONNECTED DIODES Series Configuration

... V-I characteristics show that the diodes have different blocking voltages. In forward biased state, the voltage drop and the forward current would be same on the diodes. While in the reverse biased the blocking voltage is different as the diodes have to carry the same leakage current. This problem ...
Zero-Sequence Harmonics Current Minimization Using Zero
Zero-Sequence Harmonics Current Minimization Using Zero

... the total harmonic current to zero, realize the purposes of realtime compensation harmonic current[1][2][12]. Its performance advantages: -with adaptive function; -can also achieve the harmonic and reactive power compensation; -Because it can track power grid’s frequency changes, so it is not affect ...
Short-circuit current ratings 3MB
Short-circuit current ratings 3MB

... • NEC® Article 100 Definition • Highest current an OVERCURRENT DEVICE (fuse or circuit breaker) is rated to safely interrupt. • Self protection rating only ...
CTcircuitsAnsb
CTcircuitsAnsb

LCM-40(DA), LCM-60(DA) installation manual
LCM-40(DA), LCM-60(DA) installation manual

... ‧Use suitable mounting tools to do the wiring and mounting (see 5) ‧Use a MCB (miniature circuit breaker) with an adequate current rating to protect the lighting system (see 6) ...
Voltmeters and ammeters are used to measure voltage and current
Voltmeters and ammeters are used to measure voltage and current

... The two crucial characteristics of any galvanometer are itsresistance and its current sensitivity. Current sensitivity is the current that gives a full-scale deflection of the galvanometer's needle -- in other words, the maximum current that the instrument can measure. For example, a galvanometer w ...
EASA Weekend Technician Class 9
EASA Weekend Technician Class 9

< 1 ... 172 173 174 175 176 177 178 179 180 ... 353 >

Earthing system

In electricity supply systems, an earthing system or grounding system is circuitry which connects parts of the electric circuit with the ground, thus defining the electric potential of the conductors relative to the Earth's conductive surface. The choice of earthing system can affect the safety and electromagnetic compatibility of the power supply. In particular, it affects the magnitude and distribution of short circuit currents through the system, and the effects it creates on equipment and people in the proximity of the circuit. If a fault within an electrical device connects a live supply conductor to an exposed conductive surface, anyone touching it while electrically connected to the earth will complete a circuit back to the earthed supply conductor and receive an electric shock.A protective earth (PE), known as an equipment grounding conductor in the US National Electrical Code, avoids this hazard by keeping the exposed conductive surfaces of a device at earth potential. To avoid possible voltage drop no current is allowed to flow in this conductor under normal circumstances. In the event of a fault, currents will flow that should trip or blow the fuse or circuit breaker protecting the circuit. A high impedance line-to-ground fault insufficient to trip the overcurrent protection may still trip a residual-current device (ground fault circuit interrupter or GFCI in North America) if one is present. This disconnection in the event of a dangerous condition before someone receives a shock, is a fundamental tenet of modern wiring practice and in many documents is referred to as automatic disconnection of supply (ADS). The alternative is defence in depth, where multiple independent failures must occur to expose a dangerous condition - reinforced or double insulation come into this latter category.In contrast, a functional earth connection serves a purpose other than shock protection, and may normally carry current. The most important example of a functional earth is the neutral in an electrical supply system. It is a current-carrying conductor connected to earth, often, but not always, at only one point to avoid flow of currents through the earth. The NEC calls it a groundED supply conductor to distinguish it from the equipment groundING conductor. Other examples of devices that use functional earth connections include surge suppressors and electromagnetic interference filters, certain antennas and measurement instruments.Regulations for earthing system vary considerably among countries and among different parts of electric systems. Most low voltage systems connect one supply conductor to the earth (ground).People use an earthing system mainly for these applications: To protect a structure from lightning strike, directing the lightning through the earthing system and into the ground rod rather than passing through the structure. Part of the safety system of mains electricity, preventing problems associated with floating ground and sky voltage. The most common ground plane for large monopole antenna and some other kinds of radio antenna.Other, less common applications of earthing systems include: single-wire earth return. part of a system that powers small devices from sky voltage. one at each end of a ground dipole ELF antenna.