Safety First!
Safety First!
•
T0A6
A good way to guard against electrical shock at your station:
• Use three-wire cords and plugs for all AC powered equipment;
• Connect all AC powered station equipment to a common safety ground;
Safety First!
• Use a circuit protected by a ground-fault interrupter.
•
T0A3
The green wire in a three-wire electrical AC plug is safety ground.
Hot (Live)
Neutral
Ground
AC Line Connections
Safety First!
•
•
A fuse or circuit breaker in series with the AC "hot" conductor is safety
equipment that should always be included in home-built equipment that is
powered from 120V AC power circuits.
T0A4 The purpose of a fuse in an electrical circuit is to interrupt power in
case of overload.
T0A13
Slow-Blow fuse
Automobile fuse
Place the fuses as close to the battery as possible
Fuses
Safety First!
•
•
It is unwise to install a 20-ampere fuse in the place of a 5-ampere
fuse because excessive current could cause a fire.
T0A12 The kind of hazard that might exist in a power supply when it is
turned off and disconnected is that you might receive an electric shock
from stored charge in large capacitors.
T0A5
Charges stored
from capacitors
can HURT !
Filter Capacitors
Safety First!
A commonly accepted value for the lowest voltage that can cause a
dangerous electric shock is 30 volts.
•
T0A1
•
T0A2
Current flowing through the body cause a health hazard:
 By heating tissue;
 It disrupts the electrical functions of cells;
 It causes involuntary muscle contractions.
•
One way to recharge a 12-volt lead-acid station battery if the
commercial power is out is to connect the battery to a car's battery and
run the engine.
T0A8
Safety First!
If a lead-acid storage battery is charged or discharged too quickly
it could overheat and give off flammable gas or explode
•
T0A10
•
T0A9
•
T0B4
A hazard is presented by a conventional 12-volt storage battery with
its explosive gas that can collect if not properly vented.
Looking for and staying clear of any overhead electrical wires is an
important safety precaution to observe when putting up an antenna
tower.
• Overhead electrical wires carry more than 120 VAC
• Use common sense and think safety first
• Have help, don’t work alone
Safety First!
•
The minimum safe distance to allow from a power line when
installing an antenna so that if the antenna falls unexpectedly, no part
of it can come closer than 10 feet to the power wires.
T0B6
• This is a ‘minimum’ distance
• Keep away from all wires
•
You should avoid attaching an antenna to a utility pole as the
antenna could contact high-voltage power wires.
T0B9
• And it may be illegal to do
Safety First!
•
Putting on a climbing harness and safety glasses is a good
precaution to observe before climbing an antenna tower.
T0B2
Climbing
Harness
Safety
Glasses
And
Hard Hat
Safety First!
•
T0B3
It is never safe to climb a tower without a helper or observer.
• Never work on a tower without a helper
•
An important safety rule to remember when using a crank-up tower
is that this type of tower must never be climbed unless it is in the fully
retracted position.
T0B7
• Think weight overload and never climb a cranked up tower
• T0B11 Grounding requirements for an amateur radio tower or antenna
are established by local electrical codes
• Always wear hard hat and safety glasses
• Check local codes before putting up an antenna
•
Proper grounding method for a tower is to have separate eight-foot
long ground rods for each tower leg, bonded to the tower and each
other.
T0B8
Safety First!
•
T4A8
A Flat strap conductor is best to use for RF grounding.
• Offers best surface area
• Bleed off static and minimize ground currents
• Straps usually are 3 inches wide
• Folding okay to snake down to a healthy ground rod
Copper Foil Ground Strap Provides
Good Surface Area Ground
Safety First!
•
•
•
A good practice when installing ground wires on a tower for
lightning protection is to ensure that connections are short and direct.
T0B10 Concerning grounding conductors used for lightning protection,
sharp bends must be avoided.
T0A7 Precautions should be taken when installing devices for lightning
protection in a coaxial cable feedline by grounding all of the protectors
to a common plate which is in turn connected to an external ground.
T0A11
• Good for nearby lightning strikes
• Direct hits, forget it, kiss everything goodbye for good
•
Members of a tower work team should wear a hard hat and safety
glasses at all times when any work is being done on the tower.
T0B1
• On ground or up the tower
• Wear hard hat and safety glasses
Safety First!
•
T0B5
The purpose of a gin pole is to lift tower sections or antennas.
Gin Pole
Safety First!
•
Factors affecting the RF exposure of people near an amateur
station antenna:
T0C4
 Frequency and power level of the RF field
 Distance from the antenna to a person
 Radiation pattern of the antenna
Controlled
Uncontrolled
Safety First!
•
•
•
Exposure limits vary with frequency because the human body
absorbs more RF energy at some frequencies than at others.
T0C2 With 3.5 MHz, 50 MHz, 440 MHz, and 1296 MHz; a 50 MHz
frequency has the lowest Maximum Permissible Exposure limit.
T0C3 The maximum power level that an amateur radio station may use
at VHF frequencies before an RF exposure evaluation is required is 50
watts PEP at the antenna.
T0C5
Never stand in front of a microwave feedhorn
antenna. On transmit, it radiates a
concentrated beam of RF energy.
Safety First!
•
T0C1
VHF and UHF radio signals are non-ionizing radiation.
• Quite different from X-ray, gamma ray, and ultra violet radiation
•
Acceptable methods to determine that your station complies with
FCC RF exposure regulations:
T0C6
 By calculation based on FCC OET Bulletin 65
 By calculation based on computer modeling
 By measurement of field strength using calibrated equipment
•
An action amateur operators might take to prevent exposure to RF
radiation in excess of FCC-supplied limits is to relocate antennas.
T0C8
The safest place to mount the
mobile antenna for minimum RF
exposure is on the metal roof as
shown.
Safety First!
•
•
•
To make sure your station stays in compliance with RF safety
regulations, re-evaluate the station whenever an item of equipment is
changed.
T0C11 When referring to RF exposure, "duty cycle" is the ratio of "on-air"
time to total operating time of a transmitted signal.
T0C10 Duty cycle is one of the factors used to determine safe RF
radiation exposure levels because it affects the average exposure of
people to radiation.
T0C9
Safety First!
•
If a person accidentally touched your antenna while you were
transmitting they might receive a painful RF burn.
T0C7
• Accidentally or on purpose, depending on the power too.
Be sure to place your antennas where
no one can touch them. All antennas,
not just the mobile ones.
Element 2 Technician Class Question
Pool
Safety First!
Valid July 1, 2010
Through
June 30, 2014
T0A06
What is a good way to guard against electrical
shock at your station?
A. Use three-wire cords and plugs for all AC
powered equipment
B. Connect all AC powered station equipment
to a common safety ground
C. Use a circuit protected by a ground-fault
interrupter
D. All of these choices are correct
T0A03
What is connected to the green wire in a
three-wire electrical AC plug?
A.
B.
C.
D.
Neutral
Hot
Safety ground
The white wire
What safety equipment should always be
included in home-built equipment that is
powered from 120V AC power circuits?
T0A13
A. A fuse or circuit breaker in series with the AC
"hot" conductor
B. An AC voltmeter across the incoming power
source
C. An inductor in series with the AC power source
D. A capacitor across the AC power source
T0A04
What is the purpose of a fuse in an
electrical circuit?
A. To prevent power supply ripple from
damaging a circuit
B. To interrupt power in case of overload
C. To limit current to prevent shocks
D. All of these choices are correct
T0A05
Why is it unwise to install a 20-ampere fuse
in the place of a 5-ampere fuse?
A. The larger fuse would be likely to blow
because it is rated for higher current
B. The power supply ripple would greatly
increase
C. Excessive current could cause a fire
D. All of these choices are correct
What kind of hazard might exist in a power
supply when it is turned off and disconnected?
T0A12
A. Static electricity could damage the
grounding system
B. Circulating currents inside the
transformer might cause damage
C. The fuse might blow if you remove the
cover
D. You might receive an electric shock from
stored charge in large capacitors
Which is a commonly accepted value for
the lowest voltage that can cause a
dangerous electric shock?
T0A01
A.
B.
C.
D.
12 volts
30 volts
120 volts
300 volts
T0A02
A.
B.
C.
D.
How does current flowing through the body
cause a health hazard?
By heating tissue
It disrupts the electrical functions of cells
It causes involuntary muscle contractions
All of these choices are correct
T0A08
What is one way to recharge a 12-volt leadacid station battery if the commercial
power is out?
A. Cool the battery in ice for several hours
B. Add acid to the battery
C. Connect the battery to a car's battery and
run the engine
D. All of these choices are correct
What can happen if a lead-acid storage battery is
charged or discharged too quickly?
T0A10
A. The battery could overheat and give off
flammable gas or explode
B. The voltage can become reversed
C. The “memory effect” will reduce the
capacity of the battery
D. All of these choices are correct
T0A09
What kind of hazard is presented by a
conventional 12-volt storage battery?
A. It emits ozone which can be harmful to the
atmosphere
B. Shock hazard due to high voltage
C. Explosive gas can collect if not properly
vented
D. All of these choices are correct
T0B04
Which of the following is an important
safety precaution to observe when putting
up an antenna tower?
A. Wear a ground strap connected to your
wrist at all times
B. Insulate the base of the tower to avoid
lightning strikes
C. Look for and stay clear of any overhead
electrical wires
D. All of these choices are correct
What is the minimum safe distance from a power
line to allow when installing an antenna?
T0B06
A. Half the width of your property
B. The height of the power line above
ground
C. 1/2 wavelength at the operating
frequency
D. So that if the antenna falls unexpectedly,
no part of it can come closer than 10 feet
to the power wires
T0B09
Why should you avoid attaching an antenna
to a utility pole?
A. The antenna will not work properly
because of induced voltages
B. The utility company will charge you an
extra monthly fee
C. The antenna could contact high-voltage
power wires
D. All of these choices are correct
T0B02
What is a good precaution to observe
before climbing an antenna tower?
A. Make sure that you wear a grounded wrist
strap
B. Remove all tower grounding connections
C. Put on a climbing harness and safety
glasses
D. All of the these choices are correct
Under what circumstances is it safe to climb a
tower without a helper or observer?
T0B03
A. When no electrical work is being
performed
B. When no mechanical work is being
performed
C. When the work being done is not more
than 20 feet above the ground
D. Never
T0B07
Which of the following is an important
safety rule to remember when using a
crank-up tower?
A. This type of tower must never be painted
B. This type of tower must never be grounded
C. This type of tower must never be climbed unless
it is in the fully retracted position
D. All of these choices are correct
Which of the following establishes grounding
requirements for an amateur radio tower or antenna?
T0B11
A.
B.
C.
D.
FCC Part 97 Rules
Local electrical codes
FAA tower lighting regulations
Underwriters Laboratories' recommended
practices
What is considered to be a proper grounding
method for a tower?
T0B08
A. A single four-foot ground rod, driven into
the ground no more than 12 inches from
the base
B. A ferrite-core RF choke connected
between the tower and ground
C. Separate eight-foot long ground rods for
each tower leg, bonded to the tower and
each other
D. A connection between the tower base and
a cold water pipe
T4A08
Which type of conductor is best to use for
RF grounding?
A.
B.
C.
D.
Round stranded wire
Round copper-clad steel wire
Twisted-pair cable
Flat strap
Which of the following is good practice when
installing ground wires on a tower for lightning protection?
T0A11
A. Put a loop in the ground connection to prevent
water damage to the ground system
B. Make sure that all bends in the ground wires are
clean, right angle bends
C. Ensure that connections are short and direct
D. All of these choices are correct
Which of the following is true concerning
grounding conductors used for lightning protection?
T0B10
A. Only non-insulated wire must be used
B. Wires must be carefully routed with precise
right-angle bends
C. Sharp bends must be avoided
D. Common grounds must be avoided
T0A07
Which of these precautions should be taken when
installing devices for lightning protection in a coaxial cable feedline?
A. Include a parallel bypass switch for each protector so
that it can be switched out of the circuit when running
high power
B. Include a series switch in the ground line of each
protector to prevent RF overload from inadvertently
damaging the protector
C. Keep the ground wires from each protector separate and
connected to station ground
D. Ground all of the protectors to a common plate which is
in turn connected to an external ground
T0B01
When should members of a tower work
team wear a hard hat and safety glasses?
A. At all times except when climbing the
tower
B. At all times except when belted firmly to
the tower
C. At all times when any work is being done
on the tower
D. Only when the tower exceeds 30 feet in
height
T0B05
A.
B.
C.
D.
What is the purpose of a gin pole?
To temporarily replace guy wires
To be used in place of a safety harness
To lift tower sections or antennas
To provide a temporary ground
T0C04
A.
B.
C.
D.
What factors affect the RF exposure of
people near an amateur station antenna?
Frequency and power level of the RF field
Distance from the antenna to a person
Radiation pattern of the antenna
All of these choices are correct
T0C05
Why do exposure limits vary with frequency?
A. Lower frequency RF fields have more
energy than higher frequency fields
B. Lower frequency RF fields do not
penetrate the human body
C. Higher frequency RF fields are transient in
nature
D. The human body absorbs more RF energy
at some frequencies than at others
Which of the following frequencies has the lowest
Maximum Permissible Exposure limit?
T0C02
A.
B.
C.
D.
3.5 MHz
50 MHz
440 MHz
1296 MHz
T0C03
What is the maximum power level that an amateur
radio station may use at VHF frequencies
before an RF exposure evaluation is required?
A.
B.
C.
D.
1500 watts PEP transmitter output
1 watt forward power
50 watts PEP at the antenna
50 watts PEP reflected power
T0C01
What type of radiation are VHF and UHF
radio signals?
A.
B.
C.
D.
Gamma radiation
Ionizing radiation
Alpha radiation
Non-ionizing radiation
T0C06
Which of the following is an acceptable method to
determine that your station complies with FCC RF
exposure regulations?
A. By calculation based on FCC OET Bulletin
65
B. By calculation based on computer
modeling
C. By measurement of field strength using
calibrated equipment
D. All of these choices are correct
T0C08
Which of the following actions might amateur
operators take to prevent exposure to RF radiation
in excess of FCC-supplied limits?
A.
B.
C.
D.
Relocate antennas
Relocate the transmitter
Increase the duty cycle
All of these choices are correct
T0C09
How can you make sure your station stays
in compliance with RF safety regulations?
A. By informing the FCC of any changes made in
your station
B. By re-evaluating the station whenever an item
of equipment is changed
C. By making sure your antennas have low SWR
D. All of these choices are correct
T0C11
What is meant by "duty cycle" when
referring to RF exposure?
A. The difference between lowest usable
output and maximum rated output power
of a transmitter
B. The difference between PEP and average
power of an SSB signal
C. The ratio of "on-air" time to total operating
time of a transmitted signal
D. The amount of time the operator spends
transmitting
T0C10
Why is duty cycle one of the factors
used to determine safe RF radiation
exposure levels?
A. It affects the average exposure of people
to radiation
B. It affects the peak exposure of people to
radiation
C. It takes into account the antenna feedline
loss
D. It takes into account the thermal effects of
the final amplifier
T0C07
What could happen if a person
accidentally touched your antenna
while you were transmitting?
A. Touching the antenna could cause
television interference
B. They might receive a painful RF burn
C. They might develop radiation poisoning
D. All of these choices are correct