• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
HI-102 Guide for the Installation, Operation, and Maintenance of
HI-102 Guide for the Installation, Operation, and Maintenance of

... value shown on the nameplate. The coil insulation has been carefully selected and made with thermally upgraded materials to ensure long life at the rated temperature and 30 ambient. Overloads in excess of the rating can be tolerated if accompanied by longer periods of light loading. Severe and prol ...
inductance of coaxial cable
inductance of coaxial cable

... As can be seen from the Table, the formula (12) only gives orientational values of the cable inductance because when it was being derived a constant current density in the cross-section of conductors was assumed and part of the magnetic flux was neglected so that also the dependence on f is vague. T ...
Form B - PowerStream
Form B - PowerStream

Electrical Hazards and Arc Flash Awareness
Electrical Hazards and Arc Flash Awareness

... and knowledgeable of the construction and operation of equipment or a specific work method and be trained to recognize and avoid the electrical hazards that might be present with respect to that equipment or work method. • One who has skills and knowledge related to the construction and operation of ...
Inter-system Ground Noise: Causes and Effects
Inter-system Ground Noise: Causes and Effects

... connected to all exposed exterior metal parts on the computer equipment. The grounding connection provided at the wall receptacle is connected within the building to copper water pipes and/or structural metal parts of the building. The purpose of this arrangement is to protect the user from electric ...
LA-601-VL - ROHM Co., Ltd.
LA-601-VL - ROHM Co., Ltd.

... No technical content pages of this document may be reproduced in any form or transmitted by any means without prior permission of ROHM CO.,LTD. The contents described herein are subject to change without notice. The specifications for the product described in this document are for reference only. Up ...
Document
Document

... The low-voltage winding of a standard distribution transformer connected to a single-phase circuit is normally made with two equal coils. These sections are arranged so that they may be connected in series or parallel. ...
WLTS Hand-Held Test Set
WLTS Hand-Held Test Set

... Verify connections to external air-core neutral current sensors in 4-wire residual applications and iron-core ground CTs (current transformers) in MDGF or other directly ground-sensed applications. ...
LCM-40(DA), LCM-60(DA) installation manual
LCM-40(DA), LCM-60(DA) installation manual

... Use suitable mounting tools to do the wiring and mounting (see 5) Use a MCB (miniature circuit breaker) with an adequate current rating to protect the lighting system (see 6) ...
LA-601AB
LA-601AB

... No technical content pages of this document may be reproduced in any form or transmitted by any means without prior permission of ROHM CO.,LTD. The contents described herein are subject to change without notice. The specifications for the product described in this document are for reference only. Up ...
User`s Manual(current)
User`s Manual(current)

... Use suitable mounting tools to do the wiring and mounting (see 5) Use a MCB (miniature circuit breaker) with an adequate current rating to protect the lighting system (see 6) ...
Modeling Current Transformer (CT) Saturation for Detailed
Modeling Current Transformer (CT) Saturation for Detailed

... Problem  Since the new design includes three potential transformers with neutral grounded, we could not connect directly to the existing synchronizer system. The existing system is based on phase B at ground potential and common to all the units, whereas the units with the new protection design wi ...
EDS 08-0136 LV Network Design - Document Library
EDS 08-0136 LV Network Design - Document Library

ERMCO Components
ERMCO Components

... not have interrupting rating. They are coordinated to operate at high current levels that are typical of a transformer failure. When a transformer failure occurs, the Isolation Link will melt so that the opened primary circuit of a faulted transformer cannot be reenergized by the line crew. The isol ...
Bonding and Installation Requirements for CSST Gas Piping Systems.
Bonding and Installation Requirements for CSST Gas Piping Systems.

80-6420-10/Rev. A/12-98 - GE Healthcare Life Sciences
80-6420-10/Rev. A/12-98 - GE Healthcare Life Sciences

ISNS3371_041707_bw
ISNS3371_041707_bw

... System of AC electricity in the US cycles the current from positive to negative and back to positive 60 times a second - 60 Hz. Standard household wiring design has two 120 volt "hot" wires and a neutral which is at ground potential - two 120 volt wires are obtained by grounding the centertap of the ...
Evaluates:  MAX3535E MAX3535E Evaluation Kit General Description Features
Evaluates: MAX3535E MAX3535E Evaluation Kit General Description Features

... The MAX3535E integrates a primary-side controller and H-bridge drivers. The device contains an on-board oscillator, protection circuitry, and internal FET drivers to provide up to 500mW of power to the primary of transformer T1. The MAX3535E driver slew rate is reconfigured using jumper JU2 on the E ...
Operator Manual - Nu
Operator Manual - Nu

... indirect contact with protection wire if not in the piece to be weld. - If earthing is deliberately made on the workpiece by means of the protection wire, the connection must be as direct as possible, with the wire having a section at least equal to the welding return current wire and connected to t ...
CosmicRay Instrumentation in the First U. S. Earth Satellite
CosmicRay Instrumentation in the First U. S. Earth Satellite

... beta be greater than thirty-six, and that the difference in beta for the two transistors be less than five. It is possible to substitute Philco surface barrier type 2;\;496 transistors in this circuit, but their characteristics are somewhat more marginal. In addition to the checks prescribed above f ...
LIGHTNING THEORY – Explanations
LIGHTNING THEORY – Explanations

... generators. It has been found that there is a substantial quantity of voltage spikes and disturbances related to unstable wind conditions. Wind gusts can burst from 0 to 60 mph in less than one minute causing voltage spikes on the power grid. Surge Protective Devices (SPDs) should be utilized protec ...
Power System 1 EEE 3231 Transmission Line
Power System 1 EEE 3231 Transmission Line

... • The per-unit value of any quantity is defined as the ratio of the quantity to its base value expressed as a decimal. • The ratio in per cent is 100 times the value in per unit. • The per-unit method has an advantage over the per cent method because the product of two quantities expressed in per un ...
MCB, RCCB - Mitsubishi Electric
MCB, RCCB - Mitsubishi Electric

IFDR Scope and Requirement Comments
IFDR Scope and Requirement Comments

TB6551FAG Application Note
TB6551FAG Application Note

... in this document, and related hardware, software and systems (collectively "Product") without notice.  This document and any information herein may not be reproduced without prior written permission from TOSHIBA. Even with TOSHIBA's written permission, reproduction is permissible only if reproducti ...
< 1 ... 170 171 172 173 174 175 176 177 178 ... 353 >

Earthing system

In electricity supply systems, an earthing system or grounding system is circuitry which connects parts of the electric circuit with the ground, thus defining the electric potential of the conductors relative to the Earth's conductive surface. The choice of earthing system can affect the safety and electromagnetic compatibility of the power supply. In particular, it affects the magnitude and distribution of short circuit currents through the system, and the effects it creates on equipment and people in the proximity of the circuit. If a fault within an electrical device connects a live supply conductor to an exposed conductive surface, anyone touching it while electrically connected to the earth will complete a circuit back to the earthed supply conductor and receive an electric shock.A protective earth (PE), known as an equipment grounding conductor in the US National Electrical Code, avoids this hazard by keeping the exposed conductive surfaces of a device at earth potential. To avoid possible voltage drop no current is allowed to flow in this conductor under normal circumstances. In the event of a fault, currents will flow that should trip or blow the fuse or circuit breaker protecting the circuit. A high impedance line-to-ground fault insufficient to trip the overcurrent protection may still trip a residual-current device (ground fault circuit interrupter or GFCI in North America) if one is present. This disconnection in the event of a dangerous condition before someone receives a shock, is a fundamental tenet of modern wiring practice and in many documents is referred to as automatic disconnection of supply (ADS). The alternative is defence in depth, where multiple independent failures must occur to expose a dangerous condition - reinforced or double insulation come into this latter category.In contrast, a functional earth connection serves a purpose other than shock protection, and may normally carry current. The most important example of a functional earth is the neutral in an electrical supply system. It is a current-carrying conductor connected to earth, often, but not always, at only one point to avoid flow of currents through the earth. The NEC calls it a groundED supply conductor to distinguish it from the equipment groundING conductor. Other examples of devices that use functional earth connections include surge suppressors and electromagnetic interference filters, certain antennas and measurement instruments.Regulations for earthing system vary considerably among countries and among different parts of electric systems. Most low voltage systems connect one supply conductor to the earth (ground).People use an earthing system mainly for these applications: To protect a structure from lightning strike, directing the lightning through the earthing system and into the ground rod rather than passing through the structure. Part of the safety system of mains electricity, preventing problems associated with floating ground and sky voltage. The most common ground plane for large monopole antenna and some other kinds of radio antenna.Other, less common applications of earthing systems include: single-wire earth return. part of a system that powers small devices from sky voltage. one at each end of a ground dipole ELF antenna.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report