• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Smart Ground Test Report Springfield Energy
Smart Ground Test Report Springfield Energy

... This report describes the ground tests and analysis of the Springfield Power Station. The objective of the test and analysis was to evaluate the plant grounding system with respect to safety performance, and transfer voltage to control circuits and if necessary, to recommend grounding design enhance ...
FINAL POWER AMPLIFIER OVERVIEW FUNCTIONAL
FINAL POWER AMPLIFIER OVERVIEW FUNCTIONAL

Kirchoff`s Laws
Kirchoff`s Laws

... the 25,000 µF (0.025 F) capacitor similar to the one shown below and the Tektronix power supply with 5 V. ...
Three-Dimensional Animations of Power
Three-Dimensional Animations of Power

KD2004-CF20A
KD2004-CF20A

... POS terminals, Label printers, CAT terminals, Multi-purpose small-sized printers zFeatures 1) Using a special compact partial glaze and new heating element structure, achieves high-speed printing at 150 mm/s. 2) The use of the highly-durable conductive protective film has improved countermeasures ag ...
IMPORTANT SAFETY INSTRUCTION IF 1638 Solar Recombiner, Array Fuse, Disconnect Box
IMPORTANT SAFETY INSTRUCTION IF 1638 Solar Recombiner, Array Fuse, Disconnect Box

... Surge Protective Device (Thermally Protected) for PV applications The Surge-Trap PV provides advanced overvoltage protection to photovoltaic systems, which does not require additional over-current protection due its high short circuit withstand. ...
LEAK CURRENT HiTESTER ST5540/ST5541
LEAK CURRENT HiTESTER ST5540/ST5541

ixrfd631 - IXYS Colorado
ixrfd631 - IXYS Colorado

... method of achieving this low impedance is to bypass the power supply at the driver with a capacitance value much larger than the load capacitance. Usually, this is achieved by placing two or three different types of bypassing capacitors, with complementary impedance curves, very close to the driver ...
Low-current sensing circuit and topology for portable gamma
Low-current sensing circuit and topology for portable gamma

... configurations require the low sense current to pass through a MOSFET. When a very low current passes through a MOSFET whose internal noise is greater than the original signal, the original signal is hidden within the noise and it is therefore difficult to determine whether the measured output is th ...
Experiment 5 Arithmetic Logic Unit (ALU)
Experiment 5 Arithmetic Logic Unit (ALU)

Kostakis-etal-EST2017-Fast-acting-protection-as-a-key-enabler
Kostakis-etal-EST2017-Fast-acting-protection-as-a-key-enabler

PowerPoint Ch 32
PowerPoint Ch 32

... © 2005 Pearson Prentice Hall This work is protected by United States copyright laws and is provided solely for the use of instructors in teaching their courses and assessing student learning. Dissemination or sale of any part of this work (including on the World Wide Web) will destroy the integrity ...
Guide to the electrical parameter classifications of IEC 60950 and
Guide to the electrical parameter classifications of IEC 60950 and

Experiment: Faraday Ice Pail
Experiment: Faraday Ice Pail

... This lab consists of three main parts. In each you will set up a circuit and measure voltage and current while the battery periodically turns on and off. In the last two parts you are encouraged to develop your own methodology for measuring the resistance and inductance of the coil on the AC/DC Elec ...
Contents - Siemens
Contents - Siemens

... very long distances and to distribute it regionally into the load centres. The term “medium voltage” has been established as a result of the various high-voltage levels which have developed in the field of power transmission and distribution. Power station locations follow the availability of primary ...
PSS15S92F6-AG
PSS15S92F6-AG

... It is recommended to insert a Zener diode D1(24V/1W) between each pair of control supply terminals to prevent surge destruction. To prevent surge destruction, the wiring between the smoothing capacitor and the P, N1 terminals should be as short as possible. Generally a 0.1-0.22μF snubber capacitor C ...
Monday, Oct. 3, 2005 - UTA HEP WWW Home Page
Monday, Oct. 3, 2005 - UTA HEP WWW Home Page

... – The voltage – The resistance of the wire to the flow of electrons • Just like gunk in water pipe slows down water flow • Electrons are slowed down due to interactions with the atoms of the wire ...
Intrinsically Safe Product Handbook
Intrinsically Safe Product Handbook

... common mode disturbances, commonly associated with lightning strikes and power system earth faults and a secondary metal-oxide varistor clamping stages across the signal lines. This combination provides very robust surge protection with high transient suppression and low let-through voltages where n ...
Embedded System - 123SeminarsOnly.com
Embedded System - 123SeminarsOnly.com

design of vco using current mode logic with low supply
design of vco using current mode logic with low supply

... in oscillation frequency to the percentage change in supply voltage. Supply sensitivity decreases with increase in frequency. At higher operating frequencies, sensitivity falls below zero to a negative value[1]. LC Oscillator based VCO has high frequency and phase stability but harder to integrate i ...
Open Circuit Test of a Single Phase Transformer jXm
Open Circuit Test of a Single Phase Transformer jXm

MAX1693/(MAX1693H)/MAX1694 USB Current-Limited Switches with Fault Blanking General Description
MAX1693/(MAX1693H)/MAX1694 USB Current-Limited Switches with Fault Blanking General Description

... returns to its high-impedance state. In the MAX1694, any overcurrent longer than 10ms will latch the switch open and set FAULT low. The latch is cleared by cycling the ON input or by powering up the device again. This feature saves power by preventing the device from thermally cycling on and off in ...
Physics 09-Electric Circuits (2016)
Physics 09-Electric Circuits (2016)

Marine Electrical Check List
Marine Electrical Check List

LED lighting surge protection - International Show Caves Association
LED lighting surge protection - International Show Caves Association

... Power surge occurring during a thunderstorm is caused by direct, nearby or even distant lightning strike. Direct or nearby lightning strike is a discharge into the lightning conductor (if existing) of a building (administration, box office) or into the conducting electrical elements entering the bu ...
< 1 ... 169 170 171 172 173 174 175 176 177 ... 353 >

Earthing system

In electricity supply systems, an earthing system or grounding system is circuitry which connects parts of the electric circuit with the ground, thus defining the electric potential of the conductors relative to the Earth's conductive surface. The choice of earthing system can affect the safety and electromagnetic compatibility of the power supply. In particular, it affects the magnitude and distribution of short circuit currents through the system, and the effects it creates on equipment and people in the proximity of the circuit. If a fault within an electrical device connects a live supply conductor to an exposed conductive surface, anyone touching it while electrically connected to the earth will complete a circuit back to the earthed supply conductor and receive an electric shock.A protective earth (PE), known as an equipment grounding conductor in the US National Electrical Code, avoids this hazard by keeping the exposed conductive surfaces of a device at earth potential. To avoid possible voltage drop no current is allowed to flow in this conductor under normal circumstances. In the event of a fault, currents will flow that should trip or blow the fuse or circuit breaker protecting the circuit. A high impedance line-to-ground fault insufficient to trip the overcurrent protection may still trip a residual-current device (ground fault circuit interrupter or GFCI in North America) if one is present. This disconnection in the event of a dangerous condition before someone receives a shock, is a fundamental tenet of modern wiring practice and in many documents is referred to as automatic disconnection of supply (ADS). The alternative is defence in depth, where multiple independent failures must occur to expose a dangerous condition - reinforced or double insulation come into this latter category.In contrast, a functional earth connection serves a purpose other than shock protection, and may normally carry current. The most important example of a functional earth is the neutral in an electrical supply system. It is a current-carrying conductor connected to earth, often, but not always, at only one point to avoid flow of currents through the earth. The NEC calls it a groundED supply conductor to distinguish it from the equipment groundING conductor. Other examples of devices that use functional earth connections include surge suppressors and electromagnetic interference filters, certain antennas and measurement instruments.Regulations for earthing system vary considerably among countries and among different parts of electric systems. Most low voltage systems connect one supply conductor to the earth (ground).People use an earthing system mainly for these applications: To protect a structure from lightning strike, directing the lightning through the earthing system and into the ground rod rather than passing through the structure. Part of the safety system of mains electricity, preventing problems associated with floating ground and sky voltage. The most common ground plane for large monopole antenna and some other kinds of radio antenna.Other, less common applications of earthing systems include: single-wire earth return. part of a system that powers small devices from sky voltage. one at each end of a ground dipole ELF antenna.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report