• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Cooper-Bussmann-CCP-Customer-Training
Cooper-Bussmann-CCP-Customer-Training

complete-electricity-topic
complete-electricity-topic

Protection Fundamentals - Levine Lectronics and Lectric
Protection Fundamentals - Levine Lectronics and Lectric

... against risks involved if protection is not sufficient and not enough redundancy. • Primary objectives is to have faulted zone’s primary protection operate first, but if there are protective relays failures, some form of backup protection is provided. ...
AN2132
AN2132

... The VBAT value must be chosen taking into account the absolute maximum ratings of the device (VBTOT = 90 V). VBTOT = (VBAT + VPOS) = 90 V must not be exceeded. When ring mode is selected through the control interface, the VBAT voltage is increased by an internal circuit from it’s active level to a p ...
Dec 2003 Single IC Monitors Redundant -48V Supplies and Fuses without Precision External Components
Dec 2003 Single IC Monitors Redundant -48V Supplies and Fuses without Precision External Components

... If a fuse opens or the supply fails entirely, then all indicators for that supply indicate a warning. Figure 2 shows a slightly different approach. Each RTN pin in this case is wired to the combined return point. One LTC1921 is used for each supply. The circuit, while using essentially the same comp ...
Slides
Slides

3B2-Expt-B-Rev
3B2-Expt-B-Rev

Diathermy
Diathermy

White Paper on Secure Integrated Circuits and Systems Project
White Paper on Secure Integrated Circuits and Systems Project

Electricity Training Course
Electricity Training Course

... Chapter 1 - Electrical Safety Objectives:  Identify the types of accidents caused by electric shock.  Describe the effects on the human body of electric shock at different current levels.  Explain proper precautions against electric shock.  Identify electrical hazards related to: fuses and circu ...
Investigation 10
Investigation 10

... Does the amount of current coming from a battery seem to depend on the number of bulbs in the circuit and how they are connected? YES! ...
Transmission and Distribution 10EE53
Transmission and Distribution 10EE53

Electrical Fundamentals
Electrical Fundamentals

ElEctrical SafEty
ElEctrical SafEty

... from a circuit to a ground and shuts the current off. It measures the difference between current flowing to an electrical device and current returning from the device. It trips in as little as 1/40th of a second when it senses a difference of 5mA For example, if there is a short (current leakage) in ...
Report/Proposal/EOI Template (MS Office 2007 format)
Report/Proposal/EOI Template (MS Office 2007 format)

Verification of Ohm`s Law, Kirchoff`s Voltage Law and Kirchoff`s
Verification of Ohm`s Law, Kirchoff`s Voltage Law and Kirchoff`s

... All of the percent errors for the calculated versus measured resistance were less than eight percent. The errors appeared to increase as the resistor number increased (i.e. R1, R2 etc.). This was probably due to error accumulation in the calculations. Slight errors such as rounding in intermediate c ...
Transformer Through Faults
Transformer Through Faults

... From Reference 3 - IEEE C37-013 being evenly distributed events where one out of every three (or two out of every six) occurs evenly or randomly across the phases. In the real world case it was observed through the historic records that the failed phase had been subjected to multiple faults that inv ...
AP2552-53(A) - Diodes Incorporated
AP2552-53(A) - Diodes Incorporated

... Under-Voltage Lockout (UVLO) Whenever the input voltage falls below UVLO threshold (~2.5V), the power switch is turned off. This facilitates the design of hot-insertion systems where it is not possible to turn off the power switch before input power is removed. ...
PR570TRN
PR570TRN

... International Electrotechnical Commission (IEC) standard is 700 a ...
Experiment 2: Kirchhoff`s Law and Superposition Theorem
Experiment 2: Kirchhoff`s Law and Superposition Theorem

Technical Information Generator
Technical Information Generator

The ME118 SN754410 Dual 1A H-Bridge Module
The ME118 SN754410 Dual 1A H-Bridge Module

Elec201
Elec201

Transformer - KFUPM Faculty List
Transformer - KFUPM Faculty List

... The single-phase loads are taken care of by the three line-to-neutral circuits. An attempt is invariably made to distribute the single-phase loads almost equally among three-phases.(4:256) ...
auto transformer
auto transformer

< 1 ... 155 156 157 158 159 160 161 162 163 ... 353 >

Earthing system

In electricity supply systems, an earthing system or grounding system is circuitry which connects parts of the electric circuit with the ground, thus defining the electric potential of the conductors relative to the Earth's conductive surface. The choice of earthing system can affect the safety and electromagnetic compatibility of the power supply. In particular, it affects the magnitude and distribution of short circuit currents through the system, and the effects it creates on equipment and people in the proximity of the circuit. If a fault within an electrical device connects a live supply conductor to an exposed conductive surface, anyone touching it while electrically connected to the earth will complete a circuit back to the earthed supply conductor and receive an electric shock.A protective earth (PE), known as an equipment grounding conductor in the US National Electrical Code, avoids this hazard by keeping the exposed conductive surfaces of a device at earth potential. To avoid possible voltage drop no current is allowed to flow in this conductor under normal circumstances. In the event of a fault, currents will flow that should trip or blow the fuse or circuit breaker protecting the circuit. A high impedance line-to-ground fault insufficient to trip the overcurrent protection may still trip a residual-current device (ground fault circuit interrupter or GFCI in North America) if one is present. This disconnection in the event of a dangerous condition before someone receives a shock, is a fundamental tenet of modern wiring practice and in many documents is referred to as automatic disconnection of supply (ADS). The alternative is defence in depth, where multiple independent failures must occur to expose a dangerous condition - reinforced or double insulation come into this latter category.In contrast, a functional earth connection serves a purpose other than shock protection, and may normally carry current. The most important example of a functional earth is the neutral in an electrical supply system. It is a current-carrying conductor connected to earth, often, but not always, at only one point to avoid flow of currents through the earth. The NEC calls it a groundED supply conductor to distinguish it from the equipment groundING conductor. Other examples of devices that use functional earth connections include surge suppressors and electromagnetic interference filters, certain antennas and measurement instruments.Regulations for earthing system vary considerably among countries and among different parts of electric systems. Most low voltage systems connect one supply conductor to the earth (ground).People use an earthing system mainly for these applications: To protect a structure from lightning strike, directing the lightning through the earthing system and into the ground rod rather than passing through the structure. Part of the safety system of mains electricity, preventing problems associated with floating ground and sky voltage. The most common ground plane for large monopole antenna and some other kinds of radio antenna.Other, less common applications of earthing systems include: single-wire earth return. part of a system that powers small devices from sky voltage. one at each end of a ground dipole ELF antenna.