• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Tips for connecting 24-volt power
Tips for connecting 24-volt power

section 260573 - overcurrent protective device coordination study
section 260573 - overcurrent protective device coordination study

... B. Appropriate motor short-circuit contribution shall be included at the appropriate locations in the system so that the computer calculated values represent the highest short-circuit current the equipment will be subjected to under fault conditions. C. A tabular computer printout shall be included ...
Predicting Circuit Board Hot Spots with Electrothermal
Predicting Circuit Board Hot Spots with Electrothermal

An Introduction to Electical Machinery Safety (Paul
An Introduction to Electical Machinery Safety (Paul

... • A supply disconnecting device must be provided:  For each incoming source of supply to a machine(s) direct connection or via a feeder system - feeder systems include conductor wires, conductor bars, slip-ring assemblies, flexible cable systems (reeled, festooned) or inductive power supply systems ...
Article 555 Marinas and Boatyards
Article 555 Marinas and Boatyards

... Water level isn’t constant. Ocean tides rise and fall, while lakes and rivers vary in depth in response to rain. To provide power to a marina or boatyard, you must allow for these variations in water level between the point of use and the power source. Article 555 addresses this issue. This article ...
701930 Current Probe User’s Manual
701930 Current Probe User’s Manual

... If the wrong instrument or accessories have been delivered, or if some accessories are missing or defective, contact the dealer from which you purchased them. Current Probe (Model 701930) Main Body Accessories • One user’s manual (this document). • Carrying case ...
Ground potential rise influence near HV substations in urban
Ground potential rise influence near HV substations in urban

... the form of the grounding system, tending to become circles at larger distances. Typically the ground potential value decays in radial direction from the zone of the substation, depending on the soil structure and resistivity [7]. However, if the high voltage substation is located in the urban area, ...
EEE- Interview Question with Answers
EEE- Interview Question with Answers

... transformer.In circuit where measurements of high voltage and high current is involved they are used there.Particularly when a measuring device like voltmeter or ammeter is not able to measure such high value of quantity because of large value of torque due to such high value it can damage the measu ...
Haworth Electric Terms
Haworth Electric Terms

... installations. The National Electrical Code (NEC) is the most widely recognized code, and it applies to most installations. Some municipalities, e.g. Chicago, New York, Miami, have their own codes. Since local codes are often more restrictive than the NEC, it’s always important to check their requir ...
The Ideal Transformer Description and Circuit Symbol As with all the
The Ideal Transformer Description and Circuit Symbol As with all the

... in Fig. 7. The problem arises that the aviation authorities would like to see a red light at the top of the tower to warn aircraft. The light can be supplied from the 120-V power mains, but one terminal of the power mains is earth grounded. This is required for safety purposes should there be an ins ...
ACS750xCA-075 - Allegro Microsystems
ACS750xCA-075 - Allegro Microsystems

Evaluation and Practice Test - E Light Safety, Training and
Evaluation and Practice Test - E Light Safety, Training and

... dwelling unit for the electric dryers? The service will be 240V, single phase. There are 14 apartments in the dwelling and each apartment is equipped with a 4.2 kW dryer. A. 24,000 w B. 30,800 W C. 45,000 W D. 70,000 W 11. The outer metal sheath of interlocked MC cable is not listed as an acceptable ...
OPTIMIZATION OF CURRENT MODE LOGIC CIRCUITS
OPTIMIZATION OF CURRENT MODE LOGIC CIRCUITS

... elements allow controlling current gain which is very useful in applications. A novel electronically tunable mixed‐mode biquad filter employs only three multi‐ output current controlled current conveyor trans‐ conductance amplifiers (MO‐CCCCTAs) and two grounded capacitors ...
Advances in Environmental Biology
Advances in Environmental Biology

... Parts of a micro-grid: Micro-grids are islands that are purposefully formed in a facility or in an electricity distribution network and include at least one Distributed Energy Source (DER) and related loads [2]. Micro-grid is a small power network (typically on the scale of a few megawatts or less), ...
Application Note Power Semiconductors
Application Note Power Semiconductors

... + + + If you know one device you know all devices + + + Coming out with a Quad-, Octal- and a 16-fold channel device with identical key features an adjustment to specific ECU needs is easily possible. The devices may be used like a ...
19 OPF Safety Program Manual - Electrical Safety (pdf)
19 OPF Safety Program Manual - Electrical Safety (pdf)

...  Understand that surge suppressors only protect the items plugged into it, not back along the circuit into which it is connected.  Multiple plug outlets must be plugged directly into mounted electrical receptacles; they cannot be chained together.  Ensure that all power strips and extension cords ...
lecture notes from ECS303
lecture notes from ECS303

... Like electric current, a constant voltage is called a DC voltage and is represented by V , whereas a sinusoidally time-varying voltage is called an AC voltage and is represented by v. A dc voltage is commonly produced by a battery; ac voltage is produced by an electric generator. Current and voltage ...
All About Energy!! - SRP: Salt River Project power and water
All About Energy!! - SRP: Salt River Project power and water

... SAFETY NOTE ...
File - Shaw STEM Lab
File - Shaw STEM Lab

Circuit Breaker Box – Main Panel
Circuit Breaker Box – Main Panel

SEMI STEP: Introduction to SEMI S2-0706
SEMI STEP: Introduction to SEMI S2-0706

EMC and variable speed drives
EMC and variable speed drives

... The fundamental global standard in the field is CISPR11, also known as EN55011. This standard is applicable in all countries to so called ISM equipment = equipment or appliances designed to generate and use locally radio frequency energy for industrial, scientific, medical, domestic or similar purp ...
3.4 Poloidal Field Power Supply Systems for the EAST Steady State
3.4 Poloidal Field Power Supply Systems for the EAST Steady State

... quenching protection, and two explosive breakers (EB) are as stand-by switches. 3.4.5 PF Power Supply Control System The local control system of PF power supply provides the routine control, real-time control, communication of control data, a timing system for precise control of event initiation, an ...
ECP 11-0308 DUOBIAS Biased Differential
ECP 11-0308 DUOBIAS Biased Differential

Industrial Automation System
Industrial Automation System

... operating characteristics and sometimes multiple operating coils are used to protect electrical circuits from overload or faults; in modern electric power systems these functions are performed by digital instruments still called "protective relays". (Figure. 9 shows CONNECT WELL 8 channel, 5A, coil- ...
< 1 ... 152 153 154 155 156 157 158 159 160 ... 353 >

Earthing system

In electricity supply systems, an earthing system or grounding system is circuitry which connects parts of the electric circuit with the ground, thus defining the electric potential of the conductors relative to the Earth's conductive surface. The choice of earthing system can affect the safety and electromagnetic compatibility of the power supply. In particular, it affects the magnitude and distribution of short circuit currents through the system, and the effects it creates on equipment and people in the proximity of the circuit. If a fault within an electrical device connects a live supply conductor to an exposed conductive surface, anyone touching it while electrically connected to the earth will complete a circuit back to the earthed supply conductor and receive an electric shock.A protective earth (PE), known as an equipment grounding conductor in the US National Electrical Code, avoids this hazard by keeping the exposed conductive surfaces of a device at earth potential. To avoid possible voltage drop no current is allowed to flow in this conductor under normal circumstances. In the event of a fault, currents will flow that should trip or blow the fuse or circuit breaker protecting the circuit. A high impedance line-to-ground fault insufficient to trip the overcurrent protection may still trip a residual-current device (ground fault circuit interrupter or GFCI in North America) if one is present. This disconnection in the event of a dangerous condition before someone receives a shock, is a fundamental tenet of modern wiring practice and in many documents is referred to as automatic disconnection of supply (ADS). The alternative is defence in depth, where multiple independent failures must occur to expose a dangerous condition - reinforced or double insulation come into this latter category.In contrast, a functional earth connection serves a purpose other than shock protection, and may normally carry current. The most important example of a functional earth is the neutral in an electrical supply system. It is a current-carrying conductor connected to earth, often, but not always, at only one point to avoid flow of currents through the earth. The NEC calls it a groundED supply conductor to distinguish it from the equipment groundING conductor. Other examples of devices that use functional earth connections include surge suppressors and electromagnetic interference filters, certain antennas and measurement instruments.Regulations for earthing system vary considerably among countries and among different parts of electric systems. Most low voltage systems connect one supply conductor to the earth (ground).People use an earthing system mainly for these applications: To protect a structure from lightning strike, directing the lightning through the earthing system and into the ground rod rather than passing through the structure. Part of the safety system of mains electricity, preventing problems associated with floating ground and sky voltage. The most common ground plane for large monopole antenna and some other kinds of radio antenna.Other, less common applications of earthing systems include: single-wire earth return. part of a system that powers small devices from sky voltage. one at each end of a ground dipole ELF antenna.