• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Displacement Current 2.
Displacement Current 2.

... An example illustrating the need for the displacement current arises in connection with capacitors with no medium between the plates. Consider the charging capacitor in the figure. The capacitor is in a circuit that transfers charge (on a wire external to the capacitor) from the [top] plate to the [ ...
The Rotating Magnetic Field Oscillator System for
The Rotating Magnetic Field Oscillator System for

... To simplify the discussion of the experimental system, unless stated otherwise, the following discussion applies to one tank circuit (i.e. one antenna system which contains two antennas). A 1:1 transformer electrically isolates the current source from the tank circuit. On the primary side of the tra ...
Man-1027
Man-1027

8.7 Separation of grounding conductors
8.7 Separation of grounding conductors

... It is required to carry normal load current continuously as well as abnormal or short-circuit current for short intervals, as specified. It is also required to open or close circuits either when negligible current is broken or made, or when no significant change in the voltage across the terminals o ...
(6) Apparatus for Class II and Class III Locations
(6) Apparatus for Class II and Class III Locations

... raceway, cable tray or cable along with nonincendive field wiring circuits when installed as long as : 1. Conductors are within a grounded metal shield OR 2. Conductors of each circuit have insulation with min thickness of .25mm b) In enclosures, conductors of IS circuits shall be secured so that an ...
Ambiguity of the Peak Power Rating of TVS Devices
Ambiguity of the Peak Power Rating of TVS Devices

Negative-Sequence Impedance Directional Element
Negative-Sequence Impedance Directional Element

... positive-sequence quantities are those present during balanced, three-phase conditions. Positivesequence quantities makeup the normal voltages and currents observed on power systems during typical, steady-state conditions. Negative-sequence quantities are a measure of the amount of unbalance existin ...
Seismic Evidence
Seismic Evidence

... – Recall also that the mantle is molten, which gives it great pressure and temperature. – Given these lines of thought, it is not hard to see how the continents, already floating on the magma which is at great pressures, could be forced apart at certain areas where perhaps the crust was weaker or co ...
A Sub 1-V Constant Gm–C Switched
A Sub 1-V Constant Gm–C Switched

... For best performance, the input differential pair of the operational amplifier should not only be the same type as and , but it should operate at a current density equal to the geometric mean of the current densities of and . If this is – characteristic will occur regarddone, then a constant less of ...
Limited Availability Product
Limited Availability Product

- American Champion Aircraft
- American Champion Aircraft

Domestic Electrical Appliances
Domestic Electrical Appliances

installer manual
installer manual

... Electric fences shall be installed and operated so that they cause no electrical hazard to persons, animals or their surroundings. Electric fence constructions which are likely to lead to the entanglement of animals or persons shall be avoided. An electric fence shall not be supplied from two differ ...
(MR15 Regulations)II Mid Examination
(MR15 Regulations)II Mid Examination

... 26. Bandwidth is defined as the range of frequencies within which the power delivered to R is a) equal to half power at resonance b) less than half the power at resonance c) greater than half power at resonance d) None. 27 . When a pure Lc parallel circuit is in resonance, the circuit condition can ...
Electric and Magnetic Power - Everything You Need to Succeed 4th
Electric and Magnetic Power - Everything You Need to Succeed 4th

... is called an electric field. Electric fields cannot be seen. Scientists show electric fields by drawing lines coming from an object. An electric field has the most strength when it is closest to a charged object. It loses strength as it gets farther away from the charged object. Negative electric fi ...
Document
Document

... As the current increases, the magnetic flux through a loop due to this current also increases The increasing flux induces an emf that opposes the current As the magnitude of the current increases, the rate of increase lessens and hence the induced ...
Zetex - AN46 - Zetex` current monitors with PolySwitchŽ overcurrent
Zetex - AN46 - Zetex` current monitors with PolySwitchŽ overcurrent

... PolySwitch overcurrent device PolySwitch PPTC (Polymeric Positive temperature Coefficient) devices are protection devices for circuits, often called resettable fuses. They are placed in circuit as a series element; allowing current to flow into a circuit under normal operation and protect a circuit ...
question bank
question bank

... 55. A straight conductor of circular x-section carries a current. Which one of the following statements is true in this regard? (a) No force acts on the conductor at any point. (b) An axial force acts on the conductor tending to increase its length. (c) A radial force acts towards the axis tending t ...
ACS752SCA-100 - Digi-Key
ACS752SCA-100 - Digi-Key

OPA129 Difet Ultra-Low Bias Current OPERATIONAL AMPLIFIER
OPA129 Difet Ultra-Low Bias Current OPERATIONAL AMPLIFIER

... input bias current can be achieved without resorting to small-geometry FETs or CMOS designs which can suffer from much larger offset voltage, voltage noise, drift, and poor power-supply rejection. The OPA129 special pinout eliminates leakage current that occurs with other op amps. Pins 1 and 4 have ...
triggering boards for thyristors
triggering boards for thyristors

999502- How To Eliminate Engine Noises-Amps
999502- How To Eliminate Engine Noises-Amps

Welcome to the new GE PowerPoint template!
Welcome to the new GE PowerPoint template!

... • Heat losses are present in Rectifier and Inverter ...
Impact of Bonding Requirements for CSST on LP
Impact of Bonding Requirements for CSST on LP

TRANSPORT CANADA Regulator Load Calculations AIRPORTS
TRANSPORT CANADA Regulator Load Calculations AIRPORTS

... change to a lower drop. The designer should consult with the CCR and electronic component manufacturer to determine if there are compatibility issues to consider. 8.5.7 Circuit stability and loading on circuits with signs. 8.5.7.1 Some airside signs may contain a saturable transformer that ensure a ...
< 1 ... 150 151 152 153 154 155 156 157 158 ... 353 >

Earthing system

In electricity supply systems, an earthing system or grounding system is circuitry which connects parts of the electric circuit with the ground, thus defining the electric potential of the conductors relative to the Earth's conductive surface. The choice of earthing system can affect the safety and electromagnetic compatibility of the power supply. In particular, it affects the magnitude and distribution of short circuit currents through the system, and the effects it creates on equipment and people in the proximity of the circuit. If a fault within an electrical device connects a live supply conductor to an exposed conductive surface, anyone touching it while electrically connected to the earth will complete a circuit back to the earthed supply conductor and receive an electric shock.A protective earth (PE), known as an equipment grounding conductor in the US National Electrical Code, avoids this hazard by keeping the exposed conductive surfaces of a device at earth potential. To avoid possible voltage drop no current is allowed to flow in this conductor under normal circumstances. In the event of a fault, currents will flow that should trip or blow the fuse or circuit breaker protecting the circuit. A high impedance line-to-ground fault insufficient to trip the overcurrent protection may still trip a residual-current device (ground fault circuit interrupter or GFCI in North America) if one is present. This disconnection in the event of a dangerous condition before someone receives a shock, is a fundamental tenet of modern wiring practice and in many documents is referred to as automatic disconnection of supply (ADS). The alternative is defence in depth, where multiple independent failures must occur to expose a dangerous condition - reinforced or double insulation come into this latter category.In contrast, a functional earth connection serves a purpose other than shock protection, and may normally carry current. The most important example of a functional earth is the neutral in an electrical supply system. It is a current-carrying conductor connected to earth, often, but not always, at only one point to avoid flow of currents through the earth. The NEC calls it a groundED supply conductor to distinguish it from the equipment groundING conductor. Other examples of devices that use functional earth connections include surge suppressors and electromagnetic interference filters, certain antennas and measurement instruments.Regulations for earthing system vary considerably among countries and among different parts of electric systems. Most low voltage systems connect one supply conductor to the earth (ground).People use an earthing system mainly for these applications: To protect a structure from lightning strike, directing the lightning through the earthing system and into the ground rod rather than passing through the structure. Part of the safety system of mains electricity, preventing problems associated with floating ground and sky voltage. The most common ground plane for large monopole antenna and some other kinds of radio antenna.Other, less common applications of earthing systems include: single-wire earth return. part of a system that powers small devices from sky voltage. one at each end of a ground dipole ELF antenna.