• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Superconducting IR magnets (F.S.Chen)
Superconducting IR magnets (F.S.Chen)

... • The grounding resistances of all coils were far less than requirement (20Mohm). ...
No Slide Title
No Slide Title

... • High-frequency currents can be measured with thermocouple meters. • Digital capacitance meters measure the time required to charge the capacitor. • Digital inductance meters measure the inductor’s cemf. • Wattmeters measure true power. • Impedance can be measured by the equivalentresistance method ...
Digital Multimeter Instruction Manual UTLDM1 English
Digital Multimeter Instruction Manual UTLDM1 English

High-Powered Output Devices
High-Powered Output Devices

... • Allows isolation between power ground and logic ground. • Discrete, direct-microcontroller circuits mix grounds and can suffer from noise. ...
Using a circuit-driven approach to teach printed
Using a circuit-driven approach to teach printed

... Moderate current-carrying paths, like the path from the MOSFET’s gate driver to the MOSFET’s gate, also warrant some attention because of their peak switching current characteristics. The issues that apply to high current, fast-switching paths also apply to moderate current-carrying paths, but in a ...
ground_talk
ground_talk

... coordinate along the wire. ...
RL circuit
RL circuit

... LC circuit is an idealization of the real world Every real circuit has a non-zero resistance value Resistance in a circuit can be regarded to in a similar way as friction in a mechanical setup In comparison to LC circuit: inductor stores less energy than initially stored in capacitor due to i2R loss ...
Class 8 - Generation Technology ~EMD 1305
Class 8 - Generation Technology ~EMD 1305

section 264313 - surge protection for low
section 264313 - surge protection for low

Fuses - Time Delay
Fuses - Time Delay

... Permit the Use of Smaller and Less Costly Switches ...
2. about the power-tek generator
2. about the power-tek generator

... The POWER-TEK is a sophisticated electronic device and should be treated accordingly. When selecting the operating environment for the POWER-TEK, don’t think of it in the same terms as other equipment that works with it, e.g. batteries, diesel generators, motor generators, washing machines, etc. It ...
KD3418211827
KD3418211827

... technique, have been developed. The complete comparison between the proposed and standard configurations has been carried out in this work. Compared to the conventional topology, the proposed system permits to reduce the rectifier switch currents, the THD of the grid current and to increase the faul ...
Interface Protection for HDMI
Interface Protection for HDMI

... ESD pulses directly into ground, and positive pulses back to ground through a zener diode. Each of the signal lines exposed to the HDMI connector are protected in this manner. All of these clamps are further prevented from providing a DC backdrive path through a blocking circuit from the biasing sup ...
Device circuit breakers
Device circuit breakers

Trouble - MacMate
Trouble - MacMate

... disconnection of the blocking capacitor in a speaker, corrosion of a switch in a manual station, failure of a photo-receptor in a smoke detector Device inoperable yet not cause a trouble condition. Only caught during a regular, periodic inspection. ...
Faraday`s Law
Faraday`s Law

... ammeter, the ammeter deflects as shown, indicating that a current is induced in the loop. (b) When the magnet is held stationary, there is no induced current in the loop, even when the magnet is inside the loop. (c) When the magnet is moved away • from the loop, the ammeter deflects in the opposite ...
Sepam 1000 - Schneider Electric Belgique
Sepam 1000 - Schneider Electric Belgique

PSCH20PP
PSCH20PP

... order for charge to flow in a conducting wire, the wire must be connected to a complete loop that includes a source of electrical energy.  Charges flow from areas of high potential energy to areas of lower potential energy. Potential difference is the difference in electrical potential energy betw ...
ASE 112 Electrical Fundamentals
ASE 112 Electrical Fundamentals

... Condition Statement: Unless otherwise indicated, evaluation of student’s attainment of objectives is based on knowledge gained from this course. Specifications may be in the form of, but not limited to, cognitive skills diagnostic instruments, manufacturer’s specifications, technical orders, regulat ...
Electricity - Evergreen State College Archives
Electricity - Evergreen State College Archives

... and the constant has units of Nm2/c2. When charged particles move we get a current. Solid materials can be divided into one of four categories based on how easy it is for a current to exist; conductors, insulators, semiconductors, and superconductors. Superconductors are a class of materials that ha ...
PV Commissioning forms - Sustainable Technologies Evaluation
PV Commissioning forms - Sustainable Technologies Evaluation

Electrical measurement safety
Electrical measurement safety

... wiring and transformers (less than an ohm on a 480 V ac circuit) • Once an arc begins, it feeds off any matter in its path and vaporizes it ...
INSTRUCTION MANUAL OPTICAL INTERFACE UNIT (CROSS
INSTRUCTION MANUAL OPTICAL INTERFACE UNIT (CROSS

050 Electronic Tuning Fork Example Project
050 Electronic Tuning Fork Example Project

... To find values for RA and RB I need to consider what preferred values are available. I chose a 3.6kΩ resistor for RA, which then left me with RB as 20kΩ. I connected up these values to my astable circuit and connected a digital frequency meter to the output. When I connected the battery, the frequen ...
Unit 4F Circuits and conductors Science Year 4
Unit 4F Circuits and conductors Science Year 4

... This unit builds on children’s previous practical experience of making circuits and extends their understanding of circuits, conductors and insulators and the need for a complete circuit in order for a device to work. Children are introduced to ways in which they can vary the current in a circuit. E ...
< 1 ... 159 160 161 162 163 164 165 166 167 ... 353 >

Earthing system

In electricity supply systems, an earthing system or grounding system is circuitry which connects parts of the electric circuit with the ground, thus defining the electric potential of the conductors relative to the Earth's conductive surface. The choice of earthing system can affect the safety and electromagnetic compatibility of the power supply. In particular, it affects the magnitude and distribution of short circuit currents through the system, and the effects it creates on equipment and people in the proximity of the circuit. If a fault within an electrical device connects a live supply conductor to an exposed conductive surface, anyone touching it while electrically connected to the earth will complete a circuit back to the earthed supply conductor and receive an electric shock.A protective earth (PE), known as an equipment grounding conductor in the US National Electrical Code, avoids this hazard by keeping the exposed conductive surfaces of a device at earth potential. To avoid possible voltage drop no current is allowed to flow in this conductor under normal circumstances. In the event of a fault, currents will flow that should trip or blow the fuse or circuit breaker protecting the circuit. A high impedance line-to-ground fault insufficient to trip the overcurrent protection may still trip a residual-current device (ground fault circuit interrupter or GFCI in North America) if one is present. This disconnection in the event of a dangerous condition before someone receives a shock, is a fundamental tenet of modern wiring practice and in many documents is referred to as automatic disconnection of supply (ADS). The alternative is defence in depth, where multiple independent failures must occur to expose a dangerous condition - reinforced or double insulation come into this latter category.In contrast, a functional earth connection serves a purpose other than shock protection, and may normally carry current. The most important example of a functional earth is the neutral in an electrical supply system. It is a current-carrying conductor connected to earth, often, but not always, at only one point to avoid flow of currents through the earth. The NEC calls it a groundED supply conductor to distinguish it from the equipment groundING conductor. Other examples of devices that use functional earth connections include surge suppressors and electromagnetic interference filters, certain antennas and measurement instruments.Regulations for earthing system vary considerably among countries and among different parts of electric systems. Most low voltage systems connect one supply conductor to the earth (ground).People use an earthing system mainly for these applications: To protect a structure from lightning strike, directing the lightning through the earthing system and into the ground rod rather than passing through the structure. Part of the safety system of mains electricity, preventing problems associated with floating ground and sky voltage. The most common ground plane for large monopole antenna and some other kinds of radio antenna.Other, less common applications of earthing systems include: single-wire earth return. part of a system that powers small devices from sky voltage. one at each end of a ground dipole ELF antenna.