• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
AC Interference on Pipeline from Power Line Fault
AC Interference on Pipeline from Power Line Fault

... • AC corrosion can be controlled in part by optimizing CP levels – not too little, not too much, just enough. ...
Section G7: Computer Simulation of Op-Amp Circuits
Section G7: Computer Simulation of Op-Amp Circuits

... op-amp circuits using PSpice. Once again, Spice (in all its incarnations) is the industry standard and seems to be the software of choice for our class. Generally, if you are comfortable with what’s truly going on with your device, circuit or system, it’s not too painful to use various simulators. I ...
AC / DC Power Supply Choices and Safety for
AC / DC Power Supply Choices and Safety for

... hoses attached to a water main. Some hoses are bigger than others to accommodate a greater flow (current) at a particular pressure (voltage). If your timing building requirements for power were simply tapped into a much larger “hose” servicing the power needs of a lift, if the lift suddenly shuts of ...
to the Basic Electricity Quiz
to the Basic Electricity Quiz

... 2. A green wire fastened to metal parts of equipment means ______.  the metal parts are electrically connected  the metal parts are part of the fan circuits  the equipment and parts are environmentally safe  none of the answers provided ...
Magnetism - WordPress.com
Magnetism - WordPress.com

What is PCB
What is PCB

... The inductance of a trace may be signifigant. For power connections, a shunt capacitor is added to counter the series inductance of a long trace. A capacitor has a low AC impedance source A 100nF capacitor is often used along with a larger capacitor. 100 nF ceramics have very low impedance at higher ...
2013 46 Spring Wiring Matters
2013 46 Spring Wiring Matters

... subject. The author describes the effects of open-circuit PEN/CEN conductors but fails to mention the effects of high resistances in these conductors – especially the failure or malfunction of highercurrent equipment due to volts drop across the high resistance. I have experienced several such situa ...
generator set synchroning with and running in parallel with the
generator set synchroning with and running in parallel with the

... The end result is that the generator set will now be the only power source connected to the load. ...
CA132045EN/ Old 240-93
CA132045EN/ Old 240-93

... is operating in delayed mode, the ASL reclaim time may extend by up to 15% while for instantaneous tripping operation at lower values of current near the pick-up value, reclaim times will be reduced. For details see Performance Characteristics. For these reasons it is recommended that the maximum re ...
Selecting cables and fuses Lesson Element
Selecting cables and fuses Lesson Element

AN INTELLIGENT HOT-SWAP CONTROLLER FOR ATCA FRU
AN INTELLIGENT HOT-SWAP CONTROLLER FOR ATCA FRU

... plugged into the backplane, a fuse might open. This is because the board is designed to operate without interruption, even If one of the fuses is open. It is difficult to detect a fuse failure and the operator will only detect one when both fuses are open, at which time it could be too late to maint ...
Open-circuit Test
Open-circuit Test

Lesson 2: Electrical Resistance
Lesson 2: Electrical Resistance

... - The electrical resistance of an object depends on the resistivity of the material it is made from; its physical measurements (cross-sectional area and length); and its temperature. Be able to - Calculate electrical resistance; resistivity; length; or cross-sectional area of an object. - Select gra ...
Short Circuit
Short Circuit

Regulations relating to maritime electrical installations
Regulations relating to maritime electrical installations

Short Circuit
Short Circuit

... 3In, 5In & 10In, depending on B, C & D characteristics Instantaneous/Magnetic Tripping 10 times the rated current; Tripping time must comply with time current curve 100ms is the limit for trip time 6 times In (but not less than 150A) at Rated Voltage Icn 10In or 500A whichever is higher (Tripping th ...
AN9842: Implementing Tip and Ring Protection Circuitry For
AN9842: Implementing Tip and Ring Protection Circuitry For

... Figure 1 shows a typical implementation for a single stage ringing SLIC where through SLIC ringing is used. The circuit usually consists of fuses, PTCs (poly switch), RFI capacitors, diode bridges, and TVS devices such as the Intersil SGT27S10. This combination of protection circuitry must clamp the ...
EHV AC Substations : Layout, Equipment, Bus arrangements
EHV AC Substations : Layout, Equipment, Bus arrangements

Fault Line Selection Method of Small Current Grounding System
Fault Line Selection Method of Small Current Grounding System

... transient DC component of the inductor current. Their amplitude not only can’t offset each other, but also even may be superposed with each other, which leads to the amplitudes of transient grounding current increasing obviously. Based on the above analysis we can get following conclusion: after the ...
Electricity & Magnetism Review 4: Units 17-19, 22-23
Electricity & Magnetism Review 4: Units 17-19, 22-23

... (Positive values indicate current flows to the right) ...
High-Power GaAs FET Device Bias
High-Power GaAs FET Device Bias

Power Factor Correction and Harmonics
Power Factor Correction and Harmonics

... harmonic current sources are injecting currents into the supply and the frequency of one of the harmonics coincides with the resonant frequency of the supply transformer and Power Factor Correction capacitor combination, the system resonates and a large circulating harmonic current is excited betwee ...
High-Voltage, Linear High-Brightness LED Driver with Open-LED Fault Detect MAX16839 General Description
High-Voltage, Linear High-Brightness LED Driver with Open-LED Fault Detect MAX16839 General Description

... drops below 30mV for 25µs. When the fault condition is detected, a 2.8mA current source charges the capacitor between FLTS and ground, up to 15V or to VIN if VIN is less than 15V. If the voltage on FLTS is greater than 1.65V due to the charge retained in the FLTS capacitor, the LED driver is turned ...
Busbar Trunking System
Busbar Trunking System

... Busbar trunking system in compact design is the most efficient, safe and ideal system for electricity supply to industrial installations and high rise structures, offering a wide current range from 125A to 2000A in type CBC (Copper conductor) and 160A to 1250A in type CBA (Aluminium conductor) with ...
Installation Instructions Model PSC-12
Installation Instructions Model PSC-12

< 1 ... 161 162 163 164 165 166 167 168 169 ... 353 >

Earthing system

In electricity supply systems, an earthing system or grounding system is circuitry which connects parts of the electric circuit with the ground, thus defining the electric potential of the conductors relative to the Earth's conductive surface. The choice of earthing system can affect the safety and electromagnetic compatibility of the power supply. In particular, it affects the magnitude and distribution of short circuit currents through the system, and the effects it creates on equipment and people in the proximity of the circuit. If a fault within an electrical device connects a live supply conductor to an exposed conductive surface, anyone touching it while electrically connected to the earth will complete a circuit back to the earthed supply conductor and receive an electric shock.A protective earth (PE), known as an equipment grounding conductor in the US National Electrical Code, avoids this hazard by keeping the exposed conductive surfaces of a device at earth potential. To avoid possible voltage drop no current is allowed to flow in this conductor under normal circumstances. In the event of a fault, currents will flow that should trip or blow the fuse or circuit breaker protecting the circuit. A high impedance line-to-ground fault insufficient to trip the overcurrent protection may still trip a residual-current device (ground fault circuit interrupter or GFCI in North America) if one is present. This disconnection in the event of a dangerous condition before someone receives a shock, is a fundamental tenet of modern wiring practice and in many documents is referred to as automatic disconnection of supply (ADS). The alternative is defence in depth, where multiple independent failures must occur to expose a dangerous condition - reinforced or double insulation come into this latter category.In contrast, a functional earth connection serves a purpose other than shock protection, and may normally carry current. The most important example of a functional earth is the neutral in an electrical supply system. It is a current-carrying conductor connected to earth, often, but not always, at only one point to avoid flow of currents through the earth. The NEC calls it a groundED supply conductor to distinguish it from the equipment groundING conductor. Other examples of devices that use functional earth connections include surge suppressors and electromagnetic interference filters, certain antennas and measurement instruments.Regulations for earthing system vary considerably among countries and among different parts of electric systems. Most low voltage systems connect one supply conductor to the earth (ground).People use an earthing system mainly for these applications: To protect a structure from lightning strike, directing the lightning through the earthing system and into the ground rod rather than passing through the structure. Part of the safety system of mains electricity, preventing problems associated with floating ground and sky voltage. The most common ground plane for large monopole antenna and some other kinds of radio antenna.Other, less common applications of earthing systems include: single-wire earth return. part of a system that powers small devices from sky voltage. one at each end of a ground dipole ELF antenna.