• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Go Picture These!
Go Picture These!

Electricity - Uses of Electromagnetism
Electricity - Uses of Electromagnetism

... A relay allows one circuit to control another circuit by turning it on and off. What will happen when the switch in circuit A is closed? ...
KV5x High Speed ADC Design Reference Manual
KV5x High Speed ADC Design Reference Manual

Product news - Danielson Europe
Product news - Danielson Europe

TSP-WG6-20MA-15V-04 - Axiomatic Technologies Corporation
TSP-WG6-20MA-15V-04 - Axiomatic Technologies Corporation

A. Internal Inductance
A. Internal Inductance

... supplies, they usually receive 230-250 V at their inlet points. While a domestic customer with a low power consumption gets a single-phase supply, both industrial and commercial consumers get three-phase supplies not only because their consumption is high but also because many of them use three-phas ...
MAX16126/MAX16127 Evaluation Kits Evaluate: MAX16126
MAX16126/MAX16127 Evaluation Kits Evaluate: MAX16126

... Detailed Description of Hardware The MAX16126/MAX16127 EV kits demonstrate a high overvoltage protection circuit for automotive applications that must survive load-dump and high-voltage transient conditions. Additional zener diodes at the input of the ICs provide extended positive voltage-range prot ...
CN-0204: 灵活、高精度、低漂移的PLC/DCS模拟输出模块
CN-0204: 灵活、高精度、低漂移的PLC/DCS模拟输出模块

... Continued from first page) Circuits from the Lab circuits are intended only for use with Analog Devices products and are the intellectual property of Analog Devices or its licensors. While you may use the Circuits from the Lab circuits in the design of your product, no other license is granted by im ...
Q2 All except 2-5
Q2 All except 2-5

Switchyard - 123SeminarsOnly.com
Switchyard - 123SeminarsOnly.com

... Isolators:In electrical engineering, a disconnecter or isolator switch is used to make sure that an electrical circuit can be completely de-energized for service or maintenance. Such switches are often found in electrical distribution and industrial applications where machinery must have its source ...
horstmann gmbh
horstmann gmbh

To read a diagram, we must understand a circuit. Here is Dictionary
To read a diagram, we must understand a circuit. Here is Dictionary

SECTION 620 is deleted and the following substituted: 620
SECTION 620 is deleted and the following substituted: 620

... For span wire assemblies, use the span wire to connect the ground rod assemblies or arrays of the poles. Do not use guy wires for grounding purposes, however bond any guy wire to the span wire as part of the intersection grounding network. 620-3.4 Grounding Traffic Control Systems on Highways: Insta ...
91049
91049

... Automatic Source Transfer All electrical distribution systems are subject to service interruptions and outages; however, there are many critical loads which cannot tolerate prolonged service interruptions. For such applications, a load-transfer scheme is used to minimize outage times. In a load tran ...
ACS755xCB-150 - Allegro Microsystems
ACS755xCB-150 - Allegro Microsystems

... information being relied upon is current. Allegro’s products are not to be used in life support devices or systems, if a failure of an Allegro product can reasonably be expected to cause the failure of that life support device or system, or to affect the safety or effectiveness of that device or sys ...
1 General - Eskom Board
1 General - Eskom Board

2007 24 Autumn Wiring Matters
2007 24 Autumn Wiring Matters

... HSE’s publication HSR25 Memorandum of guidance on the Electricity at Work Regulations 1989. This person should be capable of inspecting the equipment and, where necessary, dismantling it to check the cable connections. Care should always be exercised when conducting tests. Inappropriate tests can da ...
Lab 0: Introduction to Circuits Laboratory
Lab 0: Introduction to Circuits Laboratory

TD1016: An overview of Lightning Protection for Ham
TD1016: An overview of Lightning Protection for Ham

... equipment, the current will follow the chassis to the safety ground. This could elevate the equipment cabinets to deadly voltages, deadly for both people and components. Even though the inductive properties of the coax cable appear to be beneficial, and extra inductance can be created by adding a fe ...
bymbm`
bymbm`

... tube 4 through a transformer 5. The power tube ing generating circuit and the anode voltage sup, l is of the tetrode type having a cathode 6 which ply circuit, di?‘iculty is encountered in control ling the amplitude of the horizontal beam de 25 is connected to ground through a cathode resistor 7; Co ...
Evaluates:  MAX5943A/B/C/D/E MAX5943A Evaluation Kit General Description Features
Evaluates: MAX5943A/B/C/D/E MAX5943A Evaluation Kit General Description Features

... When the ORing function is disabled, the MAX5943A controller will fully enhance MOSFET N1-A, during normal operation, regardless of the load-current condition. In this mode, current can flow from the output OUT to the input IN if the voltage present at the OUT terminal is higher than the voltage at ...
THE LIGHT BULB EXPERIMENT: Exploring Simple Electric Circuits
THE LIGHT BULB EXPERIMENT: Exploring Simple Electric Circuits

MA Utility Presentation 6.26.12
MA Utility Presentation 6.26.12

ACA-20PC Series - Murata Power Solutions
ACA-20PC Series - Murata Power Solutions

... such that minimal forces are applied to the built-in CT, TB1, or to the ammeter itself. In high-vibration environments, adequate strain reliefs be used for all load and supply wiring. To ensure a secure panel-mount installation, Murata Power Solutions recommends using the DMS-BZL4 bezel assembly (wi ...
Single-Supply Operation of Operational Amplifiers
Single-Supply Operation of Operational Amplifiers

< 1 ... 163 164 165 166 167 168 169 170 171 ... 353 >

Earthing system

In electricity supply systems, an earthing system or grounding system is circuitry which connects parts of the electric circuit with the ground, thus defining the electric potential of the conductors relative to the Earth's conductive surface. The choice of earthing system can affect the safety and electromagnetic compatibility of the power supply. In particular, it affects the magnitude and distribution of short circuit currents through the system, and the effects it creates on equipment and people in the proximity of the circuit. If a fault within an electrical device connects a live supply conductor to an exposed conductive surface, anyone touching it while electrically connected to the earth will complete a circuit back to the earthed supply conductor and receive an electric shock.A protective earth (PE), known as an equipment grounding conductor in the US National Electrical Code, avoids this hazard by keeping the exposed conductive surfaces of a device at earth potential. To avoid possible voltage drop no current is allowed to flow in this conductor under normal circumstances. In the event of a fault, currents will flow that should trip or blow the fuse or circuit breaker protecting the circuit. A high impedance line-to-ground fault insufficient to trip the overcurrent protection may still trip a residual-current device (ground fault circuit interrupter or GFCI in North America) if one is present. This disconnection in the event of a dangerous condition before someone receives a shock, is a fundamental tenet of modern wiring practice and in many documents is referred to as automatic disconnection of supply (ADS). The alternative is defence in depth, where multiple independent failures must occur to expose a dangerous condition - reinforced or double insulation come into this latter category.In contrast, a functional earth connection serves a purpose other than shock protection, and may normally carry current. The most important example of a functional earth is the neutral in an electrical supply system. It is a current-carrying conductor connected to earth, often, but not always, at only one point to avoid flow of currents through the earth. The NEC calls it a groundED supply conductor to distinguish it from the equipment groundING conductor. Other examples of devices that use functional earth connections include surge suppressors and electromagnetic interference filters, certain antennas and measurement instruments.Regulations for earthing system vary considerably among countries and among different parts of electric systems. Most low voltage systems connect one supply conductor to the earth (ground).People use an earthing system mainly for these applications: To protect a structure from lightning strike, directing the lightning through the earthing system and into the ground rod rather than passing through the structure. Part of the safety system of mains electricity, preventing problems associated with floating ground and sky voltage. The most common ground plane for large monopole antenna and some other kinds of radio antenna.Other, less common applications of earthing systems include: single-wire earth return. part of a system that powers small devices from sky voltage. one at each end of a ground dipole ELF antenna.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report