* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download PR570TRN
Electrical substation wikipedia , lookup
Current source wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Electrification wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Electric power system wikipedia , lookup
Ground loop (electricity) wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Three-phase electric power wikipedia , lookup
History of electric power transmission wikipedia , lookup
Audio power wikipedia , lookup
Power engineering wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Voltage optimisation wikipedia , lookup
Portable appliance testing wikipedia , lookup
Solar micro-inverter wikipedia , lookup
Stray voltage wikipedia , lookup
Voltage regulator wikipedia , lookup
Power inverter wikipedia , lookup
Transformer types wikipedia , lookup
Single-wire earth return wikipedia , lookup
Mains electricity wikipedia , lookup
Alternating current wikipedia , lookup
Ground (electricity) wikipedia , lookup
Buck converter wikipedia , lookup
Current mirror wikipedia , lookup
Switched-mode power supply wikipedia , lookup
PR570 POWERITE II TRAINING Dedicated to Success in Electronic Servicing for 50 Years “POWERITE II” 6 WAY SAFETY ANALYZER 1. AC Receptacle Tester & Voltage Monitor 2. AC Variable Power Supply 3. Isolation Transformer 4. Output Current/Power Monitor 5. Output Circuit Breaker 6. Safety Leakage Tester Equipment Familiarization PR570 Displays AC Receptacle & Isolated Output AC Voltages Adjusts ACV at Isolated Output Measures Current or Power Delivered to Isolated Output Displays Current, Power, & Voltage at Isolated Output VARIABLE ISOLATION TRANSFORMER & SAFETY ANALYZER POWERITE II AC VOLTS AC VOLTS HOT TO SAFTEY GND HOT TO NEUTRAL CURRENT/POWER ISOLATED OUTPUT VOLTAGE CURRENT/POWER TRIP RESET TRIP SET HOT TO EXTERNAL EARTH GND PR570 Amps POWER Amps ISOLATED OUTPUT Watts HOT CHASSIS Valid only when connected to External Earth Gnd TRIP SET CURRENT LEAKAGE uAmps uAmps MIN AUTO-TOGGLE MAX MIN AC Line Safety Gnd Both Must Light ISOLATED OUTPUT POWER OFF ON 100 uAMP LEAKAGE CAL CHECK TO EXTERNAL EARTH GND SAFETY PROBE INPUT WARNING: Set Output to 120VAC & Touch Safety Probe Here. Refer To Pull Chart Isolated Output On When Lit For Equipment Under Test Only! ! 3 Amps At 117VAC Continous, 4 Amps Intermittent Use Measures Input ACV to Safety Ground Resets Isolated Output Trip Current Measures Variable ACV at Isolated Output Measures AC Leakage Select to View Trip Current Indicates Isolated Output is Active Adjusts Isolated Output Trip Current Level Isolated Variable AC Output AC Electrical Outlet AC outlet 120VAC Hot Neutral Earth Ground AC Electric Box Neutral Hot (120VAC) Hot (120V) Black Electric Box White Green Earth Ground Rod Hot To External Earth Ground VARIABLE ISOLATION TRANSFORMER & SAFETY ANALYZER PR570 POWERITE II AC VOLTS AC VOLTS HOT TO SAFTEY GND HOT TO NEUTRAL CURRENT/POWER ISOLATED OUTPUT VOLTAGE CURRENT/POWER TRIP RESET TRIP SET HOT TO EXTERNAL EARTH GND Watts HOT CHASSIS Valid only when connected to External Earth Gnd Amps POWER Amps ISOLATED OUTPUT TRIP SET CURRENT LEAKAGE uAmps uAmps MIN AUTO-TOGGLE MAX MIN AC Line Safety Gnd Both Must Light ISOLATED OUTPUT POWER OFF ON TO EXTERNAL EARTH GND 100 uAMP LEAKAGE CAL CHECK SAFETY PROBE INPUT WARNING: Refer To Pull Chart Set Output to 120VAC & Touch Safety Probe Here. Isolated Output On When Lit For Equipment Under Test Only! ! 3 Amps At 117VAC Continous, 4 Amps Intermittent Use Earth Ground AC Receptacle Tests VARIABLE ISOLATION TRANSFORMER & SAFETY ANALYZER PR570 POWERITE II AC VOLTS AC VOLTS HOT TO SAFTEY GND HOT TO NEUTRAL CURRENT/POWER ISOLATED OUTPUT VOLTAGE CURRENT/POWER TRIP RESET TRIP SET HOT TO EXTERNAL EARTH GND Watts HOT CHASSIS Valid only when connected to External Earth Gnd Amps POWER Amps ISOLATED OUTPUT TRIP SET CURRENT LEAKAGE uAmps uAmps MIN AUTO-TOGGLE MAX MIN AC Line Safety Gnd Both Must Light ISOLATED OUTPUT POWER OFF ON TO EXTERNAL EARTH GND 100 uAMP LEAKAGE CAL CHECK SAFETY PROBE INPUT WARNING: Refer To Pull Chart Set Output to 120VAC & Touch Safety Probe Here. Isolated Output On When Lit ! 3 Amps At 117VAC Continous, 4 Amps Intermittent Use Hot Neutral For Equipment Under Test Only! Earth Ground A Variable AC Transformer Variac or Autotransformer A variac or autotransformer provides an AC output voltage variable from 0 to approximately 140 VAC. A variac does not provide isolation. Variable AC Power Supply 0-140 VAC VARIABLE ISOLATION TRANSFORMER & SAFETY ANALYZER PR570 POWERITE II AC VOLTS AC VOLTS HOT TO SAFTEY GND HOT TO NEUTRAL CURRENT/POWER ISOLATED OUTPUT VOLTAGE CURRENT/POWER TRIP RESET TRIP SET HOT TO EXTERNAL EARTH GND Watts HOT CHASSIS Valid only when connected to External Earth Gnd Amps POWER Amps ISOLATED OUTPUT TRIP SET CURRENT LEAKAGE uAmps uAmps MIN AUTO-TOGGLE MAX MIN AC Line Safety Gnd Both Must Light ISOLATED OUTPUT POWER OFF ON TO EXTERNAL EARTH GND 100 uAMP LEAKAGE CAL CHECK SAFETY PROBE INPUT WARNING: Refer To Pull Chart Set Output to 120VAC & Touch Safety Probe Here. Isolated Output On When Lit For Equipment Under Test Only! ! 3 Amps At 117VAC Continous, 4 Amps Intermittent Use Hot Ground Direct off-line DC supply with bridge rectifier results in a “HOT” chassis “HOT” ground has direct path to electrical hot side of electrical outlet Approximately 67 VDC between “HOT” ground and Earth ground Connecting a ground from a test instrument to a “HOT” ground causes high current through the diode Test Equipment V 67 VDC • An isolation transformer electrically isolates the “HOT” side of the AC plug, eliminating the voltage difference and current that may result between ground references Isolation Transformer Test Equipment V Defeating Isolation V 120VAC Between Chassis Grounds The isolation transformer can be defeated if twohot chassis are connected at the same time. Isolated Output On/Off Control VARIABLE ISOLATION TRANSFORMER & SAFETY ANALYZER PR570 POWERITE II AC VOLTS AC VOLTS HOT TO SAFTEY GND HOT TO NEUTRAL CURRENT/POWER ISOLATED OUTPUT VOLTAGE CURRENT/POWER TRIP RESET TRIP SET HOT TO EXTERNAL EARTH GND Watts HOT CHASSIS Valid only when connected to External Earth Gnd Amps POWER Amps ISOLATED OUTPUT TRIP SET CURRENT LEAKAGE uAmps uAmps MIN AUTO-TOGGLE MAX MIN AC Line Safety Gnd Both Must Light ISOLATED OUTPUT POWER OFF ON TO EXTERNAL EARTH GND 100 uAMP LEAKAGE CAL CHECK SAFETY PROBE INPUT WARNING: Set Output to 120VAC & Touch Safety Probe Here. Refer To Pull Chart Isolated Output On When Lit For Equipment Under Test Only! ! 3 Amps At 117VAC Continous, 4 Amps Intermittent Use Output Off - Output On Switch(Switches Isolated Output Voltage On or Off) Isolated Output On Indicator (On when Lit.) Isolated Output Current & Power Monitoring VARIABLE ISOLATION TRANSFORMER & SAFETY ANALYZER PR570 POWERITE II AC VOLTS AC VOLTS HOT TO SAFTEY GND HOT TO NEUTRAL CURRENT/POWER ISOLATED OUTPUT VOLTAGE CURRENT/POWER TRIP RESET TRIP SET HOT TO EXTERNAL EARTH GND Watts HOT CHASSIS Valid only when connected to External Earth Gnd Amps POWER Amps ISOLATED OUTPUT TRIP SET CURRENT LEAKAGE uAmps uAmps MIN AUTO-TOGGLE MAX MIN AC Line Safety Gnd Both Must Light ISOLATED OUTPUT POWER OFF ON TO EXTERNAL EARTH GND 100 uAMP LEAKAGE CAL CHECK SAFETY PROBE INPUT WARNING: Refer To Pull Chart Set Output to 120VAC & Touch Safety Probe Here. For Equipment Under Test Only! ! 3 Amps At 117VAC Continous, 4 Amps Intermittent Use Isolated Output Current & Watts Meter Isolated Output On When Lit Isolated Output Circuit Breaker VARIABLE ISOLATION TRANSFORMER & SAFETY ANALYZER PR570 POWERITE II AC VOLTS AC VOLTS HOT TO SAFTEY GND CURRENT/POWER ISOLATED OUTPUT VOLTAGE HOT TO NEUTRAL CURRENT/POWER TRIP RESET TRIP SET HOT TO EXTERNAL EARTH GND Watts HOT CHASSIS Valid only when connected to External Earth Gnd Amps POWER Amps ISOLATED OUTPUT TRIP SET CURRENT LEAKAGE uAmps uAmps MIN AUTO-TOGGLE MAX MIN AC Line Safety Gnd Both Must Light ISOLATED OUTPUT POWER OFF ON TO EXTERNAL EARTH GND 100 uAMP LEAKAGE CAL CHECK SAFETY PROBE INPUT WARNING: Refer To Pull Chart Set Output to 120VAC & Touch Safety Probe Here. Isolated Output On When Lit For Equipment Under Test Only! ! 3 Amps At 117VAC Continous, 4 Amps Intermittent Use Position To Meter Circuit Breaker Level 0-4Amps Reset if Circuit Breaker Trips Control Sets Circuit Breaker 0-4A • If the “HOT” ground of the power supply becomes electronically connected to exterior parts of the cabinet housing, a shock hazard exists. • Protect yourself, your business and your customer. ALWAYS perform a leakage current check after completing a repair! Causes of Excess AC Leakage Current Defective AC Line or Switching Supply Isolation Transformers Leaky AC Bypass Filter Capacitors Improper Part Installation - Safety Critical Isolation Parts Foreign Objects - Coins, screws, paper clips SMPS Safety Leakage Paths MIC 1 MIC 3 Switching Transformer MIC 2 Startup Switching Transistor Drive Generator/ Control Feedback/Control MIC 4 Switch Mode Transformer Primary to Secondary AC Input Filter Capacitors Isolation Filter Capacitors Between Hot & Isolated Grounds Effects of AC Leakage 10A Severe burns, but not fatal unless vital organs burned 5 4 1A Heart stops during shock May Restart if current is removed before death 500 250 100mA 50 Heart fibrillation in 1.4 seconds - Usually fatal Breathing stops Often fatal Highest Danger 30 10mA Cannot let go Painful sensation 5 1mA Mild sensation UL limit for consumer products 500 Imperceptible 100A UL limit for hospital equipment not connected directly to the body Safety Leakage Testing A safety leakage test ensures that the monitor doesn’t have AC line leakage to exposed metal parts Virtually all manufacturer’s service literature requires a safety leakage test be performed at the completion of any repair Safety leakage testing applies to all consumer electronic devices powered from the AC line, whether or not they have a 3-wire power cord Underwriter’s Laboratory (UL) standard is 500a Other standards may apply International Electrotechnical Commission (IEC) standard is 700 a Manufacturer Safety Leakage Test • Underwriter’s Laboratory (UL) standard is 500a • International Electrotechnical Commission (IEC) standard is 700 a 0.15 F TO INSTRUMENT'S EXPOSED METAL PARTS 1500 , 10W WATER PIPE (EARTH GROUND) 1 Do not use an isolation transformer for this test. Plug the completely reassembled unit directly into the ac outlet. 2 Connect a 1.5K, 10W resistor paralleled by an .015uF capacitor between each exposed metal cabinet part and a good earth ground such as a water pipe, as shown above. 3 Use an ac voltmeter with at least 5000 ohms/volt sensitivity to measure the potential across the resistor. 4 The potential at any point should not exceed 0.75 volts. A leakage current tester may be used to make this test; leakage current must not exceed 0.5 milliamps. If a measurement is outside of the specified limits, there is a possibility of shock hazard. The chassis should be repaired and rechecked before returning it to the customer. 5 Repeat the above procedure with the ac plug reversed. (Note: An ac adapter is necessary when a polarized plug is used. Do not defeat the polarizing feature of the plug.) Safety Leakage Testing VARIABLE ISOLATION TRANSFORMER & SAFETY ANALYZER PR570 POWERITE II AC VOLTS AC VOLTS HOT TO SAFTEY GND HOT TO NEUTRAL CURRENT/POWER ISOLATED OUTPUT VOLTAGE CURRENT/POWER TRIP RESET TRIP SET HOT TO EXTERNAL EARTH GND Watts HOT CHASSIS Valid only when connected to External Earth Gnd Amps POWER Amps ISOLATED OUTPUT TRIP SET CURRENT LEAKAGE uAmps uAmps MIN AUTO-TOGGLE MAX MIN AC Line Safety Gnd Both Must Light ISOLATED OUTPUT POWER OFF ON TO EXTERNAL EARTH GND 100 uAMP LEAKAGE CAL CHECK SAFETY PROBE INPUT WARNING: Refer To Pull Chart Set Output to 120VAC & Touch Safety Probe Here. Isolated Output On When Lit For Equipment Under Test Only! ! 3 Amps At 117VAC Continous, 4 Amps Intermittent Use Checking Leakage Test Calibration VARIABLE ISOLATION TRANSFORMER & SAFETY ANALYZER PR570 POWERITE II AC VOLTS AC VOLTS HOT TO SAFTEY GND HOT TO NEUTRAL CURRENT/POWER ISOLATED OUTPUT VOLTAGE CURRENT/POWER TRIP RESET TRIP SET HOT TO EXTERNAL EARTH GND Watts HOT CHASSIS Valid only when connected to External Earth Gnd Amps POWER Amps ISOLATED OUTPUT TRIP SET CURRENT LEAKAGE uAmps uAmps MIN AUTO-TOGGLE MAX MIN AC Line Safety Gnd Both Must Light ISOLATED OUTPUT POWER OFF ON TO EXTERNAL EARTH GND 100 uAMP LEAKAGE CAL CHECK SAFETY PROBE INPUT WARNING: Set Output to 120VAC & Touch Safety Probe Here. Refer To Pull Chart Isolated Output On When Lit For Equipment Under Test Only! ! 3 Amps At 117VAC Continous, 4 Amps Intermittent Use Set Isolated Output to 120VAC. Leakage Test Should Read 100uA +/2 Counts PR570 Function Review Displays AC Receptacle & Isolated Output AC Voltages Adjusts ACV at Isolated Output Measures Current or Power Delivered to Isolated Output Displays Current, Power, & Voltage at Isolated Output VARIABLE ISOLATION TRANSFORMER & SAFETY ANALYZER POWERITE II AC VOLTS AC VOLTS HOT TO SAFTEY GND HOT TO NEUTRAL CURRENT/POWER ISOLATED OUTPUT VOLTAGE CURRENT/POWER TRIP RESET TRIP SET HOT TO EXTERNAL EARTH GND PR570 Amps POWER Amps ISOLATED OUTPUT Watts HOT CHASSIS Valid only when connected to External Earth Gnd TRIP SET CURRENT LEAKAGE uAmps uAmps MIN AUTO-TOGGLE MAX MIN AC Line Safety Gnd Both Must Light ISOLATED OUTPUT POWER OFF ON 100 uAMP LEAKAGE CAL CHECK TO EXTERNAL EARTH GND SAFETY PROBE INPUT WARNING: Set Output to 120VAC & Touch Safety Probe Here. Refer To Pull Chart For Equipment Under Test Only! Isolated Output On When Lit ! 3 Amps At 117VAC Continous, 4 Amps Intermittent Use Measures Input ACV to Safety Ground Resets Isolated Output Trip Current Measures Variable ACV at Isolated Output Measures AC Leakage Select to View Trip Current Indicates Isolated Output is Active Adjusts Isolated Output Trip Current Level Isolated Variable AC Output GETTING STARTED: 1. Turn the PR570 power switch “ON.” Confirm proper AC supply voltage to the PR570 by reading the “HOT TO SAFETY GROUND” and “HOT TO NEUTRAL” voltages (expect 115VAC to 125VAC in the left LCD readout). NOTE: An open safety ground results in a low “HOT TO SAFETY GROUND” measurement. 2. Turn the AC VOLTS switch to the “ISOLATED OUTPUT” position. Adjust the Isolated Output Voltage (viewed in the left LCD readout) to 120 VAC using the ISOLATED OUTPUT control. 3. Set the Isolated Output “TRIP SET” to 2 AMPS by placing the CURRENT/POWER switch in the “TRIP SET” position and adjusting the TRIP SET control until 2.00 is displayed in the right LCD readout. Congratulations! You are now an experienced PR570 User