• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
University of Bejaia 2nd year Technology Lecture two: Electric circuit
University of Bejaia 2nd year Technology Lecture two: Electric circuit

Free download.
Free download.

... Dim ensi ons in ...
Chapter 8 Table of Contents Section Title Page
Chapter 8 Table of Contents Section Title Page

... The transmission system operator provides analysis capabilities for both long-term planning and real-time operations. System conditions are evaluated to ensure a bounding analysis and model parameters are selected that are influential in determining the system’s ability to provide offsite power adeq ...
KidWind Kit Inventory List:
KidWind Kit Inventory List:

... conductors are clustered together in the table; which means they must have similar  characteristics. Also, if one looks for non‐conductors (insulator elements in the chart), they will  also be clustered together.  ...
Project Proposal - ECE Senior Design
Project Proposal - ECE Senior Design

... sinusoidal angle. In order to protect other devices on the grid, the microinverter needs to meet international standards such as IEEE 1547 standards, EN61000-3-2, and U.S. NEC 690. These standards provide grid connection time, procedure, grounding methods, and so on. Unlike the commercial microinver ...
Example: This circuit is equivalent to a single capacitor having
Example: This circuit is equivalent to a single capacitor having

... capacitance C. The voltage source voltage is given by v ( t ) = 4 cos ( 3 t ) V Find the current i(t) when C = 1 F. ...
Trustworthy Sensor Networks Security Protocols
Trustworthy Sensor Networks Security Protocols

... Reconfigures the system after disturbances or interruptions Facilitates coordination with customer services such as timeof-use pricing, load management and DERs ...
Parvin-RESUME.new_.sg_1x1
Parvin-RESUME.new_.sg_1x1

... power system by applying Thyristor Controlled Phase Shifting Transformer (TCPST) from a general model of Phase Shifting Transformer (PST). It is use to improve the transient stability of power system by changing the phase angle through step change of α and ramping (continuous change of α over a peri ...
Practical 19 Characteristics of diodes
Practical 19 Characteristics of diodes

... Most current sensors have a 1 A range and are suitable for this experiment. They are generally current protected but take care to check manufacturers’ specifications and use with care. Exceeding the maximum current rating will permanently damage ammeter or sensor. ...
The Electric Circuit
The Electric Circuit

... the other end of the same power supply (closed circuit).  Current will only flow when there is a closed circuit. ...
V NL - UiO
V NL - UiO

... Adjustable – can be adjusted within a specified range of values Dual-Tracking – provides equal positive and negative output voltages ...
Leaflet Low voltage lighting installations
Leaflet Low voltage lighting installations

... + protective insulation for exposed devices (label ) + temperature protection for installation in or near flammable furniture and fixtures (label "Max. Tc 135°C", "M", "MM"). + The automatic switching off in the event of an overload or short circuit must be guaranteed by built-in secondary fuses, in ...
S03-Switching Transients Abstract
S03-Switching Transients Abstract

... Thomas J. Tobin: Thomas J. Tobin received his BEEE degree in 1968 and a ME degree in Electric Power Engineering in 1969, both from Rensselaer Polytechnic Institute. For over 30 years, he has developed fuses, switches, circuit switchers, and fault interrupters rated 15 kV through 500 kV, and received ...
Exponential Growth/Decay
Exponential Growth/Decay

... • There is a force other than gravity that acts “at a distance” (and is stronger). • This force can be attractive or repulsive • “Static Electricity” comes in two flavours; we call these positive and negative (like charges repel, unlike charges attract). • At least some of the charges in metals are ...
Font : Eurostile Extended Size : 14 Style : Bold Align
Font : Eurostile Extended Size : 14 Style : Bold Align

... There are six distribution circuits with individual fuse and indicator for better safety of equipment. 7th fuse holder has been provided in the unit to carry the spare fuse handy for any last minute use. Manual change over switch (heavy-duty toggle switch) has been provided to select any of the two ...
IMT4
IMT4

... otherwise dispose of the same, no express or implied right or license to practice or commercially exploit any intellectual property rights or other proprietary rights owned or controlled by ROHM CO., LTD. is granted to any such buyer. Products listed in this document are no antiradiation design. ...
Mass 24/25-2
Mass 24/25-2

... Mass battery chargers are designed for the toughest conditions for professional, semi-professional and recreational purposes. Even under the most extreme conditions the products from the Mass series operate faultlessly, giving you round-the-clock output when necessary. The sustainability and techn ...
App0502-11
App0502-11

... The standby supply is a low power section, acting like a little independent DC-DC converter driven directly from the 380VDC. Its purpose is to power the fans and provide a 5V, 1 ampere output for external monitoring or supervisory circuits. This standby supply voltage is always present, even if the ...
direct current - University of Iowa Physics
direct current - University of Iowa Physics

... electromagnetic  induction  discovered  independently  by  Michael Faraday in 1831 in England, and Joseph Henry in  1832 in the US. We will describe this important discovery  later  in  connection  with  magnetic  fields.  The  basic  principle is illustrated in the diagram on the right.  A coil  of ...
Transformers
Transformers

... primary and 10 coils in the secondary will reduce the voltage by a factor of 10 but multiply the current by a factor of 10 at the same time. The power is equal to the current times the voltage (watts = volts x amps is one way to remember this), so you can see the power in the secondary coil is theor ...
DMS-20PC-4/5/6-DCM - Murata Power Solutions
DMS-20PC-4/5/6-DCM - Murata Power Solutions

... connect a negative voltage across the rear terminals and the meters are fully operational! Negative-input DCM’s can be easily combined with positive-reading DMS-20PC-DCM’s for monitoring dual-polarity power supplies. Three versions are available: one for –4.50 to –19.99Vdc (0.01V resolution), one fo ...
Design_Logic_Probe
Design_Logic_Probe

... – LED 2 should light (a) when the input is open (floating) or (b) when the input voltage is between 0.8 and 2.2 V. – LED 3 should light when the input voltage is above 2.2 V. • All voltage levels have a tolerance of approximately ±12%. ...
800 A sun volt page
800 A sun volt page

G2PW...10 Voltage monitoring in 3
G2PW...10 Voltage monitoring in 3

... -25 to +55°C (in accordance with IEC 68-1) -25 to +40°C (in accordance with UL 508) -25 to +70°C -25 to +70°C 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) 3 (in accordance with IEC 60664-1) 10 to 55Hz 0.35mm (in accordance with IEC 68-2-6) 15g 11ms (in accordance with IEC 68-2-27) ...
Presentation by Marioan Piekutowski ( pptx , 59 kB ) - SC B4
Presentation by Marioan Piekutowski ( pptx , 59 kB ) - SC B4

... Interactions between multiple controllers • Avoid use of too many controllers • Coordination of set points in FRT sequence on different devices • Controlling devices with different time constant (inverter vs rotating machine) • Importance in timing coordination of different controllers ...
< 1 ... 1083 1084 1085 1086 1087 1088 1089 1090 1091 ... 1160 >

Electrical substation



A substation is a part of an electrical generation, transmission, and distribution system. Substations transform voltage from high to low, or the reverse, or perform any of several other important functions. Between the generating station and consumer, electric power may flow through several substations at different voltage levels.Substations may be owned and operated by an electrical utility, or may be owned by a large industrial or commercial customer. Generally substations are unattended, relying on SCADA for remote supervision and control.A substation may include transformers to change voltage levels between high transmission voltages and lower distribution voltages, or at the interconnection of two different transmission voltages. The word substation comes from the days before the distribution system became a grid. As central generation stations became larger, smaller generating plants were converted to distribution stations, receiving their energy supply from a larger plant instead of using their own generators. The first substations were connected to only one power station, where the generators were housed, and were subsidiaries of that power station.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report