• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Intrinsically safe distribution box RSI-iss
Intrinsically safe distribution box RSI-iss

... The RSI-iss type distribution box with line separator is suitable for galvanic separation of line sections connecting the loudspeaking GTL (GTL/w) communication devices. The box is installed in the line, each 8 maximum GTL (GTL/w) devices cooperating within one control circuit. This box separates tw ...


... The short circuit current of a squirrel cage induction motor on normal voltage is 3.5 times the  full load current and the full load slip is 4%. Determine the percentage tapping required on an  auto‐transformer starter to start the  motor against 1/3rd full load torque.  Neglect magnetizing  current ...
Solid-State RelayS
Solid-State RelayS

... as provided in Vishay’s terms and conditions of sale for such products, Vishay assumes no liability whatsoever, and disclaims any express or implied warranty, relating to sale and/or use of Vishay products including liability or warranties relating to fitness for a particular purpose, merchantabilit ...
Low voltage fast-switching NPN power transistor
Low voltage fast-switching NPN power transistor

... 1. Pulsed duration = 300 µs, duty cycle ≤1.5% ...
Easytest 10 kV
Easytest 10 kV

... operating voltage range. Either simple DC testers or insulation testers are used; however, with maximum voltages of 10 kV, they seldom come close to the operating voltage range. ...
DAY_5_~1
DAY_5_~1

Physics 3 - NYCC SP-01
Physics 3 - NYCC SP-01

... than secondary it is a step-down transformer, conversely if the number of secondary windings is greater than the number of primary windings it is a step-up transformer. ...
to the complete article
to the complete article

... 3. check the voltage on the socket pin relative to the grid of 300B, it should be about 70V 4. check the voltage on the socket pin relative to the grid of 845, it should be about 120V 5. turn the four regulators to get these correct voltages 6. switch off the amp 7. insert only the 6D22 of the vacuu ...
ECE 3442 Exam #1 - My FIT (my.fit.edu)
ECE 3442 Exam #1 - My FIT (my.fit.edu)

Industrial Rack-Mount Inverters
Industrial Rack-Mount Inverters

... DC Circuit Breaker protects the inverter and cables from becoming a potential fire hazard under fault conditions, as well as providing a point of isolation from your batteries when switched OFF. The circuit breaker is designed for ease of operation and safety. If the Inverter shuts down due to Overl ...
of Abadan Oil Refining Co.Iran.
of Abadan Oil Refining Co.Iran.

... fuzzy PI controller to regulate its DC bus voltage.As the proposed control algorithm is based on an indirect currentcontrol technique where extraction of fundamental componentsof load currents has major role in the control, it has less switchingripple in supply currents, superior performance during ...
Measuring Voltages and Currents
Measuring Voltages and Currents

... The voltmeter is the standard instrument used to measure the voltage difference between two points in a circuit. To measure V12 in the circuit below, we connect the (+) terminal of the voltmeter to terminal 1 and the (−) terminal to terminal 2. Connecting the voltmeter to the circuit does not requir ...
Induction motor control
Induction motor control

... This method is only suitable for speed control below the rated speed, since the terminal voltage cannot exceeds rated value to prevent the damage of the winding’s insulations. ...
Close Range High Voltage Multiplier Device
Close Range High Voltage Multiplier Device

... discharge. This is shown in the circuit diagram below.It may be powered by one or more batteries depending on manufacturer and model. The output voltages without external "load" (which would be the target's body) are claimed to be in the range of 50 kV up to 8 MV, .A more practical voltage range is ...
IEEE TRANSACTIONS ON POWER ELECTRONICS
IEEE TRANSACTIONS ON POWER ELECTRONICS

... IEEE Journal of Emerging and Selected Topics in Power Electronics Special Issue on Structured DC Microgrids, 2016 Scheduled Publication Time: March 2017 With the development of direct-current (DC) coupled devices such as photovoltaic generations, batteries, supercapacitors, LEDs, computers, and elec ...
Factsheet: Using Electrical Equipment in Wet Locations
Factsheet: Using Electrical Equipment in Wet Locations

... either fuses or circuit breakers. These devices are known as overcurrent protection and they are rated in amps. Most common household circuits are wired for 15 amps or 20 amps. Overcurrent protection devices protect wiring and equipment from overheating and fires. They may – or may not – protect you ...
XL80 data sheet Letter Size.indd
XL80 data sheet Letter Size.indd

... designed for high-efficiency and power-friendly operation in a broad range of industrial applications. High reliability, low harmonic distortion, and high power factor operation are designed into the drive. The TMdrive-XL80 is available with up to 3.8 kV output. ...
B320-97035
B320-97035

... circuit, select a “LO” trip rating. For a 600 A distribution system, select a “HI” trip rating. This approach to trip selection means that one indicator fits all cable diameters from 0.7” through 2.0”. With this simplified approach to rating selection: ■ Ordering is easier and reduces lead times. ■ ...
Voltage Stability and Reactive Power Planning
Voltage Stability and Reactive Power Planning

Electrical Safety -- and its implications for designing products
Electrical Safety -- and its implications for designing products

... incorporates a circuit breaker (a form of switch) which opens automatically when the line and neutral currents are not equal, i.e. when some current is leaking away to earth (the device used to be known as an Earth Leakage Circuit Breaker). These devices are normally set to operate at a current imba ...
Voltage Current Dividers Impedance
Voltage Current Dividers Impedance

... to components in series and how a current that enters the a node shared by components in parallel is distributed among the component.  Chapter 9.7 Fundamentals of Electric Circuits  Chapters 15.4, 15.6, 16.3, 16.5, 17.2, 17.5, 17.7 Principles of ...
design_review - ECE Senior Design
design_review - ECE Senior Design

... supply. We use a low-resistance sense resistor and amplifier to measure the sense voltage drop. We’ve begun characterization of this circuit on a mix of breadboard and PCB. Printed/No Lead board would mean better components. No one would be impressed, but we could turn in what we have and meet the b ...
Chapter 1 Fundamental Knowledge
Chapter 1 Fundamental Knowledge

HAS 600-S
HAS 600-S

... Basic insulation ...
Training Report on 220 to 132KV Substation
Training Report on 220 to 132KV Substation

< 1 ... 1085 1086 1087 1088 1089 1090 1091 1092 1093 ... 1160 >

Electrical substation



A substation is a part of an electrical generation, transmission, and distribution system. Substations transform voltage from high to low, or the reverse, or perform any of several other important functions. Between the generating station and consumer, electric power may flow through several substations at different voltage levels.Substations may be owned and operated by an electrical utility, or may be owned by a large industrial or commercial customer. Generally substations are unattended, relying on SCADA for remote supervision and control.A substation may include transformers to change voltage levels between high transmission voltages and lower distribution voltages, or at the interconnection of two different transmission voltages. The word substation comes from the days before the distribution system became a grid. As central generation stations became larger, smaller generating plants were converted to distribution stations, receiving their energy supply from a larger plant instead of using their own generators. The first substations were connected to only one power station, where the generators were housed, and were subsidiaries of that power station.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report