• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Schmitt Trigger
Schmitt Trigger

... output goes high at an input of .9V and goes back low at 1.7V. (These are consistent with the typical values quoted in the TI spec sheet. For the bottom plot the output goes high at 2.13V and low at 4.87V. Note that acceptable voltages can be within 0.3V of these values for the bottom plot and .2V f ...
Node Voltage with Thevenin Equivalent
Node Voltage with Thevenin Equivalent

... • Suggestion – when measuring i1, use a shunt resistor in the circuit with the same equivalent impedance as the shunt resistors in the original circuit so that you can directly compare the voltage measurements. ...
download
download

... visibility conditions where the runway visual range (RVR), is less than one-half mile requiring steady-burning approach lights with sequence flashing lights. The system consists of a master controller for monitoring and individual flashing lights that can be incorporated with steady burning lights t ...
A Carrier-Based PWM Strategy With the Offset Voltage Injection for
A Carrier-Based PWM Strategy With the Offset Voltage Injection for

... Single-phase three-level neutral point clamped (NPC) converters are widely applied in high-speed railway electrical traction drive systems. A significant problem related to the ...
Problems 2 - MyCourses
Problems 2 - MyCourses

... Calculate the fault apparent power and the fault current. 12. W7.2 Two 100MVA, 20kV turbo-generators (each of transient reactance 0.2 pu) are connected, each through its own 100MVA, 0.1 pu reactance transformer, to a common 132kV busbar. From this busbar, a 132kV feeder, 40km in length, supplies an ...
Ohm`s Law, Power, Simple Circuits
Ohm`s Law, Power, Simple Circuits

Simple Electrical Circuits
Simple Electrical Circuits

98.6 - Masters in Solar
98.6 - Masters in Solar

... As at least two phases of a three-phase feed-in design feed energy into the grid, it is not necessary to provide for intermediate energy storage in the device, as must be done in the case of single-phase feed-in. For this reason, the coolcept 3-x inverters dispense completely with the electrolytic c ...
ISOLATION VOLTAGE
ISOLATION VOLTAGE

... Withstand Voltage Dielectric Withstand Voltage Flash Tested Proof Voltage ...
Automatic Speed Control
Automatic Speed Control

V 1 by
V 1 by

... Two different physically different components could have the same relationship between the voltage and current. If they do, for the purpose of circuit analysis they are identical ...
File
File

... 9.1 Series and Parallel Circuits Pg. 306 ...
15.5 Other Practical Considerations
15.5 Other Practical Considerations

Basic Electrical Circuits
Basic Electrical Circuits

Boost converter Operation - San Jose State University
Boost converter Operation - San Jose State University

Generators and Transformers
Generators and Transformers

ASCO Power Control Center Upgrades ASCO Group 5 Power Control Center
ASCO Power Control Center Upgrades ASCO Group 5 Power Control Center

Ohms Law - PHS Regents Physics
Ohms Law - PHS Regents Physics

Reigh Walling Commen.. - pes-psrc
Reigh Walling Commen.. - pes-psrc

... Case 3. Single contingency. Branch L2 on the transmission network out of service (or other selected contingency), and full power generation from the wind farm, all generators on line. All reactive power support equipment on line under voltage regulation mode. Neglect contributions to faults at any g ...
High Voltage MLCC for use in Power Supplies
High Voltage MLCC for use in Power Supplies

... by UL and TUV for use across the line in mains voltage applications. C: Component 2220JA250472KXTB16, this component is a Y2/X1 rated safety capacitor certified by UL and TUV for use between live and ground in mains voltage applications. DC side D: Tank capacitor, usually a high capacitance value fo ...
Document
Document

... Standard covering low voltage control equipment (contactors) - AC1 Generic standard for electrical relays Generic standard for measurement and protection relays Generic standard for measurement and protection relays & thermal protection of motors ...
Swish Sleeve PCB Layout Design Narrative
Swish Sleeve PCB Layout Design Narrative

Buck-Boost Converter Introduction A Buck
Buck-Boost Converter Introduction A Buck

... However as the charge diminishes, the input voltage falls below the level required by the circuit, and either the battery must be discarded or re-charged; at this point the ideal alternative would be the boost regulator. By combining these two regulator designs it is possible to have a regulator cir ...
discharge of high voltage lines and capacitors banks
discharge of high voltage lines and capacitors banks

... VOLTAGE TRANSFORMERS In addition to the accurate measurement of the voltage on HV electricity networks, inductive voltage transformers canal so be used to discharge high voltage trapped charges. When opening the circuit breakers of an energized HV line and isolating it from earth, the voltage of thi ...
ck1005 - stereo vu meter
ck1005 - stereo vu meter

< 1 ... 1082 1083 1084 1085 1086 1087 1088 1089 1090 ... 1160 >

Electrical substation



A substation is a part of an electrical generation, transmission, and distribution system. Substations transform voltage from high to low, or the reverse, or perform any of several other important functions. Between the generating station and consumer, electric power may flow through several substations at different voltage levels.Substations may be owned and operated by an electrical utility, or may be owned by a large industrial or commercial customer. Generally substations are unattended, relying on SCADA for remote supervision and control.A substation may include transformers to change voltage levels between high transmission voltages and lower distribution voltages, or at the interconnection of two different transmission voltages. The word substation comes from the days before the distribution system became a grid. As central generation stations became larger, smaller generating plants were converted to distribution stations, receiving their energy supply from a larger plant instead of using their own generators. The first substations were connected to only one power station, where the generators were housed, and were subsidiaries of that power station.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report