Download B320-97035

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Electrification wikipedia , lookup

Mercury-arc valve wikipedia , lookup

Transformer wikipedia , lookup

Power inverter wikipedia , lookup

Variable-frequency drive wikipedia , lookup

Ohm's law wikipedia , lookup

Electronic engineering wikipedia , lookup

Pulse-width modulation wikipedia , lookup

Electrical ballast wikipedia , lookup

Current source wikipedia , lookup

Three-phase electric power wikipedia , lookup

Electric power system wikipedia , lookup

Ground (electricity) wikipedia , lookup

Resistive opto-isolator wikipedia , lookup

Rectifier wikipedia , lookup

Amtrak's 25 Hz traction power system wikipedia , lookup

Power over Ethernet wikipedia , lookup

Power electronics wikipedia , lookup

Islanding wikipedia , lookup

Power MOSFET wikipedia , lookup

Single-wire earth return wikipedia , lookup

Metadyne wikipedia , lookup

Transformer types wikipedia , lookup

Circuit breaker wikipedia , lookup

Buck converter wikipedia , lookup

Earthing system wikipedia , lookup

Immunity-aware programming wikipedia , lookup

Opto-isolator wikipedia , lookup

Power engineering wikipedia , lookup

Fault tolerance wikipedia , lookup

Voltage optimisation wikipedia , lookup

Electrical substation wikipedia , lookup

Stray voltage wikipedia , lookup

Switched-mode power supply wikipedia , lookup

History of electric power transmission wikipedia , lookup

Surge protector wikipedia , lookup

Electrical wiring in the United Kingdom wikipedia , lookup

National Electrical Code wikipedia , lookup

Alternating current wikipedia , lookup

Mains electricity wikipedia , lookup

Transcript
PRODUCT BRIEF
Cooper Power Systems
manufactures a line of Superior,
Tough And Reliable faulted circuit
indicators to fit your application.
BULLETIN B320-97035
S.T.A.R.™ Low Voltage Reset Type Faulted Circuit Indicators
A Reliable and Highly Visible Means of Detecting Underground Faults Quickly
Description:
Cooper Power Systems’ S.T.A.R. Low Voltage Reset (LVR) faulted circuit indicators (FCIs) can be installed
on pad-mounted distribution transformers, or at a secondary voltage source. The unit automatically resets
to the normal position when circuit voltage is restored.
The S.T.A.R. LVR FCI is comprised of a sensor, a remote display and a secondary power cable. A six
foot fiber optic cable connects the sensor to the display, eliminating any electrical or metallic connection
between the primary side and the secondary side of the transformer. The FISHEYE™ display, with a
highly reflective orange target, provides enhanced 180 degree visibility for remote indication. The display
fits a standard remote indicator window used on pad- mounted transformers. The display is black under
normal conditions.
The selection of a LVR faulted circuit indicator has never been easier! For conventional indicators, trip
ratings are selected based on cable diameter, load current and minimum fault current levels. Trip rating
selection for S.T.A.R. faulted circuit indicators has been reduced to two simple choices. For a 200 A URD
circuit, select a “LO” trip rating. For a 600 A distribution system, select a “HI” trip rating. This approach to
trip selection means that one indicator fits all cable diameters from 0.7” through 2.0”.
With this simplified approach to rating selection:
■ Ordering is easier and reduces lead times.
■ Inventory is reduced, eliminating the need to stock multiple designs.
■ Pre-installation load surveys are not needed.
■ FCI changeouts are not necessary as systems grow.
■ Misapplication due to trip selection errors is eliminated.
For SCADA applications, auxiliary contacts can be added. The magnetic latching circuit that operates the
auxiliary contact ensures a reliable indication.
Design Features:
These design features are standard on every S.T.A.R. faulted circuit indicator:
■ Inrush Restraint: Eliminates false tripping due to recloser operations
■ Low Pass Filter: Prevents tripping on high frequency transients
■ Temperature Compensation Circuitry: Assures accurate, reliable performance over a
wide temperature range
■ Reliable Open Core CT Design: Eliminates tripping due to adjacent magnetic fields
■ Quick Response Time: Coordinates with all current-limiting fuses
■ Tough, Durable Construction: Corrosion-proof, damage-resistant, display status cannot
mechanically change
■ Exceeds ANSI®/IEEE Standard 495-1986™
■ Quick and Easy Installation: Only one hot stick is required
PRODUCT BRIEF
S.T.A.R.™ Low Voltage Reset Type Faulted Circuit Indicators
Electrical
Ratings and
Characteristics:
Description
Power Requirements
Reset Requirements
Reset Time
Trip Current
Trip Accuracy
Trip Response Speed
Maximum Continuous Load Current
Fault Withstand Capability
Cable Size
Temperature Range
Materials
Weight
Auxiliary Contact Ratings
Ratings and Characteristics
105 VAC, 15 mA @ 120 VAC
87 VAC minimum
6 to 9 seconds
Factory Preset, (High and Low)
+/- 10%
Response Curve, Figure 4, Sec. 320-50
600 A
25 kA for 10 cycles per ANSI®/IEEE 495-1986™
#2 to 1000 MCM, Insulated
-40˚ C to +85˚ C
Corrosion-resistant & submersible per ANSI®/IEEE 495-1986™
26.7 ounces (0.76 kg)
1A
30 VDC
0.5 A
125 VAC
0.3 A
110 VAC
5.2”
(132 mm)
3.7”
(94 mm)
2.0”
(51 mm)
.6”
(14 mm)
4.4”
(112 mm)
3.6”
(91 mm)
.41”
(10 mm)
2.5”
(64 mm)
5.7”
(145 mm)
1.8”
(46 mm)
SENSOR
.42”
(11 mm)
2.2”
(56 mm)
1.75”
(45 mm)
SECONDARY
POWER CABLE
1.4”
(36 mm)
REMOTE DISPLAY
Because we’ve incorporated so many “custom” features into our standard design, we’ve drastically
reduced the part numbers. This makes ordering easier and delivery faster. Use the diagram below to
select the S.T.A.R. Low Voltage Reset Type faulted circuit indicator for your application. Contact your local
Cooper Power Systems sales engineer for catalog section 320-50 and additional information.
Ordering
Information:
Standard
Digits: 1
S
2
L
3
H
4
I
5
A
6
S.T.A.R. FCI Line
FCI Type
Digit
2
L
Example: A Low Voltage Reset FCI with a
high trip rating and standard 6 ft. auxiliary
contacts would have a catalog number
SLHIA (as shown below).
Options
7
Options
Trip Rating
5
A
Digits
Type
Low Voltage Reset
3
4
L O
H I
Trip Rating
Digits
6 7
Descriptions
*Standard Indicator with
auxiliary contacts
* Indicator with auxiliary contacts provided with 6 ft.
length as standard.
Low
High
Notes:
1. The S.T.A.R. FCI catalog number may vary in length from 4 digits to 7 digits.
2. The standard S.T.A.R. FCI catalog number may be truncated after entering digits 1-4. Options may be selected by
adding the appropriate design code to digits 5, 6, and/or 7.
© 2006 Cooper Power Systems, Inc., or its affiliates.
S.T.A.R.™ and FISHEYE ™ are trademarks of Cooper Power Systems, Inc., or
its affiliates.
IEEE Standard 495-1986™ is a trademark of the Institute of Electrical and
Electronics Engineers.
ANSI® is a registered trademark of the American National Standards Institute.
Bulletin B320-97035 • June 2006 • Suppersedes 1/98