TECHNICAL DEFINITION
... Operate time means the time from when the rated voltage is applied to the coil of a single side stable type relay until either form A contact closes or form B contact opens, whichever is longer. Set time means the time after applied to the rated voltage on the set coil of a latching type relay. It d ...
... Operate time means the time from when the rated voltage is applied to the coil of a single side stable type relay until either form A contact closes or form B contact opens, whichever is longer. Set time means the time after applied to the rated voltage on the set coil of a latching type relay. It d ...
NCP3065, NCV3065 Up to 1.5 A Constant Current Switching Regulator for LEDs
... the IC in the event that the maximum junction temperature is exceeded. When activated, typically at 165°C, the Darlington Output Switch is disabled. The temperature sensing circuit is designed with some hysteresis. The Darlington Switch is enabled again when the chip temperature decreases under the ...
... the IC in the event that the maximum junction temperature is exceeded. When activated, typically at 165°C, the Darlington Output Switch is disabled. The temperature sensing circuit is designed with some hysteresis. The Darlington Switch is enabled again when the chip temperature decreases under the ...
Drake_TR-4C HF Comms Reciever_Manual
... when the Mode switch is on X-CW or X-AM. It should also be noted that if the relays fail to close occasionally when the key is used, advance the VOX gain (screwdriver adjust on the right side of the chassis) until positive relay action is obtained. In the X-AM position, a controlled carrier screen m ...
... when the Mode switch is on X-CW or X-AM. It should also be noted that if the relays fail to close occasionally when the key is used, advance the VOX gain (screwdriver adjust on the right side of the chassis) until positive relay action is obtained. In the X-AM position, a controlled carrier screen m ...
Data sheet NRS 2-50, 2-51
... external semi-delay fuse 0.5 A. The power supply unit must be electrically isolated from dangerous contact voltages and must meet at least the requirements on double or reinforced isolation according to one of the following standards: DIN EN 50178, DIN EN 61010-1, DIN EN 60730-1 or DIN EN 60950. To ...
... external semi-delay fuse 0.5 A. The power supply unit must be electrically isolated from dangerous contact voltages and must meet at least the requirements on double or reinforced isolation according to one of the following standards: DIN EN 50178, DIN EN 61010-1, DIN EN 60730-1 or DIN EN 60950. To ...
Preventing Excess Power Consumption on
... The TS5A3159A analog switch operates normally if VOH of the control input is greater than or equal to V+, up to 5.5 V max. However, if VOH of the control signal is less than V+, it leads to excessive current consumption as shown in the summary table. The excess current consumption problem can be sol ...
... The TS5A3159A analog switch operates normally if VOH of the control input is greater than or equal to V+, up to 5.5 V max. However, if VOH of the control signal is less than V+, it leads to excessive current consumption as shown in the summary table. The excess current consumption problem can be sol ...
Switch
![](https://commons.wikimedia.org/wiki/Special:FilePath/Switches-electrical.agr.jpg?width=300)
In electrical engineering, a switch is an electrical component that can break an electrical circuit, interrupting the current or diverting it from one conductor to another.The mechanism of a switch may be operated directly by a human operator to control a circuit (for example, a light switch or a keyboard button), may be operated by a moving object such as a door-operated switch, or may be operated by some sensing element for pressure, temperature or flow. A relay is a switch that is operated by electricity. Switches are made to handle a wide range of voltages and currents; very large switches may be used to isolate high-voltage circuits in electrical substations.