![UNIONMELT® ELECTRONIC WELDING CONTROL](http://s1.studyres.com/store/data/007796123_1-5c9025ef5b17947165c7a3238d10a1d4-300x300.png)
MAX1693/(MAX1693H)/MAX1694 USB Current-Limited Switches with Fault Blanking General Description
... condition causes the switch to current limit at 0.7A to 1.0A and FAULT to go low after the 10ms blanking period. When the overcurrent condition is removed, FAULT returns to its high-impedance state. In the MAX1694, any overcurrent longer than 10ms will latch the switch open and set FAULT low. The la ...
... condition causes the switch to current limit at 0.7A to 1.0A and FAULT to go low after the 10ms blanking period. When the overcurrent condition is removed, FAULT returns to its high-impedance state. In the MAX1694, any overcurrent longer than 10ms will latch the switch open and set FAULT low. The la ...
FSA1208 Low-Power, Eight-Port, High-Speed Isolation Switch FSA1208 — Low-Power, Eight-Port, Features
... Package drawings are provided as a service to customers considering Fairchild components. Drawings may change in any manner without notice. Please note the revision and/or date on the drawing and contact a Fairchild Semiconductor representative to verify or obtain the most recent revision. Package s ...
... Package drawings are provided as a service to customers considering Fairchild components. Drawings may change in any manner without notice. Please note the revision and/or date on the drawing and contact a Fairchild Semiconductor representative to verify or obtain the most recent revision. Package s ...
RF5745 2.4GHz TO 2.5GHz, 802.11b/g/n SINGLE-BAND FRONT END MODULE Features
... The RF5745 is an integrated front-end module (FEM) for high performance ZigBee® (802.15.4) and WiFi (802.11b/g) applications in the 2.4GHz to 2.5GHz ISM band. The FEM addresses the need for aggressive size reduction by integrating 50 matching networks to all RF ports and minimizing the number of ex ...
... The RF5745 is an integrated front-end module (FEM) for high performance ZigBee® (802.15.4) and WiFi (802.11b/g) applications in the 2.4GHz to 2.5GHz ISM band. The FEM addresses the need for aggressive size reduction by integrating 50 matching networks to all RF ports and minimizing the number of ex ...
Measuring instrument of the potentiometer type
... In this embodiment one end of relay 36 is con In the operation of this embodiment of the nected, as previously, to the contact 2| while invention a de?ection of the galvanometer pointer the other end is connected both to one contact 2 will move contact 26 into engagement with, of the switch 35 and o ...
... In this embodiment one end of relay 36 is con In the operation of this embodiment of the nected, as previously, to the contact 2| while invention a de?ection of the galvanometer pointer the other end is connected both to one contact 2 will move contact 26 into engagement with, of the switch 35 and o ...
Electrical Installations Level 2 - Pearson Schools and FE Colleges
... On a composite cable installation, where the conductors other than brown are used as a phase conductor, they should be fitted with a brown sleeve at their terminations. All conductors must be contained within a non-combustible enclosure at wiring outlets (i.e. the sheathing of the cable must be take ...
... On a composite cable installation, where the conductors other than brown are used as a phase conductor, they should be fitted with a brown sleeve at their terminations. All conductors must be contained within a non-combustible enclosure at wiring outlets (i.e. the sheathing of the cable must be take ...
Room temperature control unit insert Necessary accessories For
... 60730-1 when correctly installed on a level, nonconductive, inflammable surface. ...
... 60730-1 when correctly installed on a level, nonconductive, inflammable surface. ...
Basis for Kelvin Contacts
... force contact is actually delivering the proper signal to the device lead. Also, in applications where the Kelvin capability is not used but the same signal is applied to both force and sense contacts, the additional redundant contact provides added assurance that the signal is actually reaching the ...
... force contact is actually delivering the proper signal to the device lead. Also, in applications where the Kelvin capability is not used but the same signal is applied to both force and sense contacts, the additional redundant contact provides added assurance that the signal is actually reaching the ...
FPF2174 IntelliMAX™ Advanced Load Management Products FP F2
... output. The integrated solution provides full protection to systems and loads which may encounter large current conditions in a very compact MLP 3x3 package. This device contain a 0.125 current-limited P-channel MOSFET which can operate over an input voltage range of 1.8-5.5V. The Schottky diode act ...
... output. The integrated solution provides full protection to systems and loads which may encounter large current conditions in a very compact MLP 3x3 package. This device contain a 0.125 current-limited P-channel MOSFET which can operate over an input voltage range of 1.8-5.5V. The Schottky diode act ...
Full-Text PDF
... a polarity reversal occurs: VS becomes higher than VD (basically, the substring starts dissipating power). Again, switch control keeps T1 in the off-state. However, when the charge pump sees a positive input voltage, it is activated and starts to generate the internal supply voltages (VDD , VQQ and ...
... a polarity reversal occurs: VS becomes higher than VD (basically, the substring starts dissipating power). Again, switch control keeps T1 in the off-state. However, when the charge pump sees a positive input voltage, it is activated and starts to generate the internal supply voltages (VDD , VQQ and ...
Local area network (LAN) packet switch remote power system
... amps, then the current How to the appliance via the Patch Cable 7 is interrupted, and the Power Fault Indicator 32 is activated. The current How to the appliance may be reas serted by operation of a reset switch 35, as shown in FIG. 1 and FIG. 3. Alternatively, the current How to the appliance may b ...
... amps, then the current How to the appliance via the Patch Cable 7 is interrupted, and the Power Fault Indicator 32 is activated. The current How to the appliance may be reas serted by operation of a reset switch 35, as shown in FIG. 1 and FIG. 3. Alternatively, the current How to the appliance may b ...
Switch
![](https://commons.wikimedia.org/wiki/Special:FilePath/Switches-electrical.agr.jpg?width=300)
In electrical engineering, a switch is an electrical component that can break an electrical circuit, interrupting the current or diverting it from one conductor to another.The mechanism of a switch may be operated directly by a human operator to control a circuit (for example, a light switch or a keyboard button), may be operated by a moving object such as a door-operated switch, or may be operated by some sensing element for pressure, temperature or flow. A relay is a switch that is operated by electricity. Switches are made to handle a wide range of voltages and currents; very large switches may be used to isolate high-voltage circuits in electrical substations.